Instruções de Operação Quadra-Fire, Modelo PELLET INSERT CB1200I

Fabricante : Quadra-Fire
Arquivo Tamanho: 5.44 mb
Arquivo Nome : 131b98e5-d417-4e60-8952-d55e3a3c52ba.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Example 2: If the equivalent length of pipe is 12 feet (3.7m) with altitude of 6,000 feet (1829m) you may use 3 or 4 inch (76 to 102mm) diameter type “L” or “PL” vent Fire Risk. Do NOT pack insulation or other combustibles between firestops. • ALWAYS maintain specified clearances around venting and firestop systems. • Install firestops as specified. Failure to keep insulation or other material away from vent pipe may cause fire. WARNING Page 14 7014-188B February 3, 2010 R R February 3, 2010 7014-188B Page 15 CB1200-I Pellet Insert 5Venting Systems NOTE: In Canada, where passage through a wall or partition of combustible construction is desired, the installation shall conform to CAN/CSA-B365. Figure 15.1 Fire Risk. Inspection of Chimney: • Masonry chimney must be in good condition. • Meets minimum standard of NFPA 211 • Factory-built chimney must be a minimum 6 inch (152mm) UL103 HT. WARNING CAUTION Never draw outside combustion air from: • Wall, floor or ceiling cavity • Enclosed space such as an attic or garage NOTE: • Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY. • Illustrations/diagrams are not drawn to scale. • Actual installation may vary due to individual design preference. A. Full Reline With Outside Air - Horizontal Outside Air through Rear Wall (Horizontal) NOTE; Use metal plate around exhaust vent pipe and seal all edges with non-flammable insulation such as fiberglass, mineral wool or ceramic. Do not use high temperature caulking materials to seal any edge to prevent furture serviceability. Page 16 7014-188B February 3, 2010 CB1200-I Pellet Insert R NOTE: Check clearances carefully for this type of installation to ensure adequate room for outside air venting. Check building codes prior to installation. • Installation MUST comply with local, regional, state and national codes and regulations. • Consult local building, fire officials or authorities having jurisdiction about restrictions, installation inspection, and permits. CAUTION NOTE: In Canada only a full reline is allowed per ULC S628, ORD ULC C1482-M1990. B. Full Reline With Outside Air - Vertical Figure 16.1 Outside Air Termination at Chimney Top (Vertical) 305mm min. below 305mm min. above NOTE; Use metal plate around exhaust vent pipe and seal all edges with non-flammable insulation such as fiberglass, mineral wool or ceramic. Do not use high temperature caulking materials to seal any edge to prevent furture serviceability. NOTE: In Canada this fireplace insert must be installed with a continous chimney liner a 6 inch (152mm) in diameter extending from the fireplace insert to the top of the chimney. The chimney liner must conform to the Class 3 requirments of CAN/ULC-S635, Standard for Lining Systems for Extising Masonry or Factory-Built Chimneys and Vents, or CAN/ULC-S640, Standard for Lining Systems for New Masonry Chimneys. R R RR R CB1200-I Pellet Insert 6Mobile Home A. Mobile Home Installation You must use a Quadra-Fire Outside Air Kit for installation in a mobile home. 1. An outside air inlet must be provided for the combustion air and must remain clear of leaves, debris, ice and/or snow. It must be unrestricted while the appliance is in use to prevent room air starvation which causes smoke spillage. Smoke spillage can also set off smoke alarms. 2. The combustion air duct system must be made of metal. It must permit zero clearance to combustible construction and prevent material from dropping into the inlet or into the area beneath the dwelling and contain a rodent screen. 3. The appliance must be secured to the mobile home structure by bolting it to the floor (using lag bolts) in two places. Use the same holes that secured the appliance to the shipping pallet. CAUTION THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED Do NOT cut through: • Floor joist, wall, studs or ceiling trusses. • Any supporting material that would affect the structural integrity. CAUTION Never draw outside combustion air from: • Wall, floor or ceiling cavity • Enclosed space such as an attic or garage 4. The appliance must be grounded with #8 solid copper grounding wire or equivalent, terminated at each end with an NEC approved grounding device. 5. Refer to Clearances to Combustibles and floor pro- tection requirements on pages 9 & 10 for listings to combustibles and appropriate chimney systems. 6. Use silicone to create an effective vapor barrier at the location where the chimney or other component penetrates to the the exterior of the structure. 7. Follow the chimney manufacturer’s instructions when installing the vent system for use in a mobile home. 8. Installation shall be in accordance with the Manufactur- ers Home & Safety Standard (HUD) CFR 3280, Part 24. Installation must comply with Manufactured Home and Safety Standard (HUD), CFR 3280, Part 24. WARNING Spark Arrestor Cap Roof Flashing Storm Collar Joist Shield/Firestop Approved Class “L” or “PL” Pellet Vent Figure 17.1 NEVER ...

Este manual também é adequado para os modelos :
Lareiras - PELLET INSERT CB1200MI-MBK (5.44 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias