Log:
Downloads : 7   Arquivo Tamanho: 6 mb   Fabricante : Napoleon Fireplaces  
Categoria : Lareiras
@name

TABLE of CONTENTS TABLE of CONTENTS PG 3-4 INTRODUCTION Warranty General Instructions General Information Care of Glass Doors, Catalytic Tiles & Plated Parts 5-12 INSTALLATION Combustion and Ventilation Air Provisions Determining Confined or Unconfined Space Gas Installation Framing Dimensions Peninsula Installation Procedure Open End Installation Procedure See-Thru Installation Procedure Island Installation Procedure 13-15 FINISHING Log Placement Glowing Embers Charcoal Embers Mantle Installati

Downloads : 1   Arquivo Tamanho: 6 mb   Fabricante : Napoleon Fireplaces  
Categoria : Lareiras
@name

Theflamemaynotappearyellowimmediately;allow15to30 minutes for the final flame colour to be established. figure 69 figure 68 AIR SHUTTER OPENING W4 5-0536 / C / 09.06.06 8 REPLACEMENTS Contact your dealer for questions concerning prices and avail-1. MoDel & SeRIal nuMBeR oF FIReplace ability of replacement parts. Normally all parts can be ordered 2. InStallatIon Date oF FIReplace through your Napoleon dealer or distributor. 3. paRt nuMBeR When ordering replacement parts always give the following

Downloads : 0   Arquivo Tamanho: 6 mb   Fabricante : Napoleon Fireplaces  
Categoria : Lareiras
@name

- 21 3/4” to top of fireplace opening. FIGURE 28 FIGURE 29 FIGURE 30 It is best to frame your fireplace after it is positioned and the vent system is installed. Use 2x4’s and frame to local building codes. Note: In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the fireplace body, it is recommended that the walls of the fireplace enclosure be “finished” (ie: drywall/sheetrock), as you would finish any other outside wall of a home. This will ensure t

Downloads : 2   Arquivo Tamanho: 6 mb   Fabricante : Napoleon Fireplaces  
Categoria : Lareiras
@name

Dry fi t the fi restop assembly before proceeding to ensure the brackets on the rear surface fi t within the horizontal framing. As an alternative to framing, the vent pipe can be enclosed in the wall using Napoleon® vent sleeve VS47KT. NOTE: THE FIRESTOP ASSEMBLY MUST BE INSTALLED WITH THE VENT SHIELD TO THE TOP. The length of the vent shield may be cut shorter for combustible walls that are less than 8 1/2" thick but the vent shield must extend the full depth of the combustible wall. 1. Apply

Downloads : 28   Arquivo Tamanho: 6 mb   Fabricante : Napoleon Fireplaces  
Categoria : Lareiras
@name

- Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier’s instructions. - If you cannot reach your gas supplier, call the fire department. - Installation and service must be performed by a qualified installer, service agency or the supplier. INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, persona

Downloads : 5   Arquivo Tamanho: 6 mb   Fabricante : Napoleon Fireplaces  
Categoria : Lareiras
@name

HINT: If glass falls into cup and surrounds the orifice, insert a clean bag into a vacuum cleaner and vacuum out glass embers or replacement glass embers can be ordered from Wolf Steel Ltd. Note: The distribution of clear glass embers over the burner tube will influence the flame height. W415-0661 / C / 02.20.08 OPTIONAL BLOWER INSTALLATION OPTIONAL BLOWER INSTALLATION BGD36CF(G) ACCESSING THE BLOWER 1. Remove the valve access door. 2. Open the main door. 3. Carefully remove the logs. 3a. (BGD36

Downloads : 6   Arquivo Tamanho: 6 mb   Fabricante : Napoleon Fireplaces  
Categoria : Lareiras
@name

Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. OPERATING INSTRUCTIONS 1. STOP! Read the safety information above on this label. 2. (If applicable) Set the thermostat to lowest setting. Turn wall on/off switch, unit mounted on/off switch or remote control switch "OFF." If used, remove the batteries from the battery holder. 9. Close control compartment. 10. If the appliance will

Downloads : 2   Arquivo Tamanho: 5 mb   Fabricante : Napoleon Fireplaces  
Categoria : Lareiras
@name

Push the vent component against the collar until it fully engages, then twist the component clockwise, running the dimples down and along the incline channels until they seat at the end of the channels. The unitized design of the Secure Vent™ components will engage and seal both the inner and outer pipe without the need for sealant or screws. If desired a #6 x 1/2" screw may be used at the joint, but it not required as the pipe will securely lock when twisted. Note: An elbow may also be attached

Downloads : 0   Arquivo Tamanho: 5 mb   Fabricante : Napoleon Fireplaces  
Categoria : Lareiras
@name

This table shows a 1(V) to 5(H) ratio. For every 1 foot of (V) vertical, you are allowed 5 feet of (H+H1) horizontal run up to a maximum total horizontal run of 20 feet. uWhen using Secure Flex, use Firestop / Spacer SF4.5VF vWhen using Secure Flex, use Firestop / Spacer SF4.5HF H1VV1HVH1HV1Figure 30 - Side Vent - THREE ELBOWS Figure 31 -Top Vent - THREE ELBOWS uCeiling Firestop / Spacer (SV4.5VF) vWall Firestop/ Spacer (SV4.5HF) uCeiling Firestop / Spacer (SV4.5VF) uWhen using Secure Flex, use

Downloads : 5   Arquivo Tamanho: 5 mb   Fabricante : Napoleon Fireplaces  
Categoria : Lareiras
@name

Install the roof flashing -Extend the vent sections through the roof structure. Install the roof flashing over the vent section and position such that the vent column rises vertically (use carpenters level -see Figure 25). Nail along perimeter to secure flashing or adjust roofing to overlap the flashing edges at top and sides only and trim where necessary. Seal the top and both sides of the flashing with waterproof caulking. J. Install the storm collar -Install the storm collar, supplied with th





categorias