Facilidade de uso


6. Wash the spray disk in a sink using warm water and a mild detergent. A bristle brush may be used to clear clogged spray holes. Rinse the spray disk with clean water and allow to air dry. 7. Wash the brew chamber in a sink using warm water and a mild detergent. A bristle brush may be used to clean the inside. Rinse with clean water and allow to air dry. 8. Reinstall the gasket INSIDE the brew head, then reinstall the spray disk. 9. Reinstall the brew chamber. 10. IMPORTANT: Do NOT submerge airpots or thermal servers in water. Wash airpots and thermal servers: a. Fill with warm soapy water b. Shake gently, then empty water c. Rinse thoroughly d. Wipe exterior with a clean soft cloth dampened with clean water. Procedure is complete CAUTION: Burn Hazard Brewing and serving temperatures of coffee are extremely hot. Hot coffee will cause serious skin burns. CAUTION: Electric Shock Hazard Do not submerge or immerse brewer in water. Do not pour or splash water into or over air vents, control panel or warmer plates. IMPORTANT: DO NOT use steel wool, sharp objects, or caustic, abrasive or chlorinated cleansers to clean the brewer or airpots or thermal servers. IMPORTANT: DO NOT submerge airpots or thermal servers in water. 11 CLEANING INSTRUCTIONS PROCEDURE: Clean Coffee Brewer PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. FREQUENCY: Daily TOOLS: Mild Detergent, Clean Soft Cloth or Sponge Bristle Brush 1. Disconnect brewer from electric power. Allow brewer to cool before cleaning. 2. Remove airpot or thermal server. 3. Remove and empty brew chamber. 4. Remove the spray disk from the brew head: Press up on the spray disk ears, then turn the disk to the left to unlatch. Remove the gasket from inside the brew head. 5. Wipe inside of brew head and area around the brew head with a soft clean cloth or sponge moistened with clean water. 6. Wash the spray disk in a sink using warm water and a mild detergent. A bristle brush may be used to clear clogged spray holes. Rinse the spray disk with clean water and allow to air dry. 7. Wash the brew chamber in a sink using warm water and a mild detergent. A bristle brush may be used to clean the inside. Rinse with clean water and allow to air dry. 8. Reinstall the gasket INSIDE the brew head, then reinstall the spray disk. 9. Reinstall the brew chamber. 10. IMPORTANT: Do NOT submerge airpots or thermal servers in water. Wash airpots and thermal servers: a. Fill with warm soapy water b. Shake gently, then empty water c. Rinse thoroughly d. Wipe exterior with a clean soft cloth dampened with clean water. Procedure is complete CAUTION: Burn Hazard Brewing and serving temperatures of coffee are extremely hot. Hot coffee will cause serious skin burns. CAUTION: Electric Shock Hazard Do not submerge or immerse brewer in water. Do not pour or splash water into or over air vents, control panel or warmer plates. IMPORTANT: DO NOT use steel wool, sharp objects, or caustic, abrasive or chlorinated cleansers to clean the brewer or airpots or thermal servers. IMPORTANT: DO NOT submerge airpots or thermal servers in water. 11 SERVICING INSTRUCTIONS — PLUMBING SERVICING INSTRUCTIONS — PLUMBING WATER TANK FUNCTION 1. Water enters at the inlet fitting of the fill solenoid (32). The solenoid admits water via a command from the controller. NOTE: The solenoid has an internal strainer. To clean the strainer: Shut off water supply. Unscrew the plastic cap protruding from the rear of the brewer. Remove the cap, inlet fitting and washer. With pliers, grasp the bar of the strainer and pull straight out. Wash any debris from the strainer. Note orientation - DO NOT reverse strainer. Reassemble and reinstall. Turn water supply back on. 2. Water enters the tank (2) thru the fill tube (16). Water is heated in the tank by the heating element (15). 3. The tank lid (9) is sealed around the edge with a gasket (6), and is secured by 3 clips (10). FILL PORT 4. Heated water is dispensed to the brew head through the VENT PORT brew tube (14), brew solenoid (18), and spout of the brew BREW PORT fitting (19). The brew solenoid is energized during the brew FAUCET PORT cycle by the controller. HEATER NOTE: The flow rate of the brew solenoid is factory set. PORTS DO NOT adjust. 5. Hot water is sprayed over the coffee grounds by the spray disc (24), which is sealed to the brew head by a gasket (23). 6. The tank is vented through the vent elbow fitting (40) and vent tubes (11 & 13). 7. Water for the hot water faucet (1) is supplied from the tank through the faucet supply tube (12). LID TANK GASKET CLIP LID GASKET SOLENOID STRAINER WASHER INLET FITTING CAP (note orientation DO NOT REVERSE) FILL SOLENOID FLOW CONTROL (installed) 12 SERVICING INSTRUCTIONS — PLUMBING (continued) ITEM DESCRIPTION PART N0. USED ON 1 2 ASSEMBLY, WATER TANK (120V) 83500 2012, 2072 2015, 2075 6 GASKET, TANK LID 83499 ALL 9 TANK LID 83504 ALL 10 RETAINING CLIP, TANK LID 83506 ALL 11 HOSE, OVERFLOW (2 pc SILICONE 4.5” LONG) 86...

Este manual também é adequado para os modelos :
Cafeteiras - 2080 (1.27 mb)
Cafeteiras - 2088 (1.27 mb)
Cafeteiras - 2082 (1.27 mb)
Cafeteiras - 2086 (1.27 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias