![@name](/images/flag/s/en.gif)
Fig. 11 Adjust Solenoid Time IMPORTANT: Before setting assembly into tank, make sure tank lid gasket is properly seated on flange of lid. IMPORTANT: When mounting thermostat, be sure a new seal washer is placed below the fitting on the capillary line. Push sensing bulb thru tank lid until fitting seats. Tighten capillary lock nut only enough to ensure no water leakage. Excessive tightening is not necessary. 13 SERVICING INSTRUCTIONS (continued) REPLACE HEATING ELEMENT Remove tank cover assembly