Log:
Assessments - , GPA: ( )

Instruções de Operação Agilent Technologies, Modelo E5500 Series

Fabricante : Agilent Technologies
Arquivo Tamanho: 200.98 kb
Arquivo Nome :

Língua de Ensino: en

O documento está colocado, por favor, espere
O documento está colocado, por favor, espere

Facilidade de uso


This series of solutions provides phase noise measurements of carrier frequencies from 50 kHz to 1.6 GHz, 6.0 GHz, 18 GHz, or 26.5 GHz over offset-from-carrier frequencies from 0.01 Hz to 100 MHz. A variety of signal generators— such as the 8662A, 8663A, 8643A, 8644B, 8664A/B, 8665A—can also be added to provide a low-noise reference signal. Phase Noise Measurement Software A graphical user interface provides measurement menus allowing the operator to specify the measurement process, including the calibration of the system. Several output formats are available to the user, including plots of the single-sideband phase noise power of the signal, integrated noise power, or the calculated Allan variance. A real-time measure-ment mode is available to monitor the level of phase noise and discrete spurs as changes are made to the device-under-test. The E5500 series phase noise measurement software requires a Pentium PC with 32 MBytes of RAM, a 1 GByte hard drive, and Windows NT 4.0. 1 It can be extended to cover offset ranges up to 100 MHZ. E5503B Specifications E5500 A-Series E5501A: 50 kHz to 1.6 GHz E5503A: 50 kHz to 18.0 GHz E5504A: 50 kHz to 26.5 GHz Operating Characteristics Offset Frequency Range A Models: 0.01 Hz to 4 MHz B Models: 0.01 Hz to 100 MHz System Noise Response2: -180 dBc/Hz typically (>10 kHz offsets) System Spurious Response2: -120 dBc typically Phase Detector Input Power: (<1.6 GHz carrier frequency) R input = 0 to +23 dBm L input = +15 to +23 dBm Downconverter Input Range: 1 GHz to 6 GHz; 1 GHz to 18 GHz; 1.5 GHz to 26.5 GHz External Noise Input Port: 0.1 Hz to 100 MHz Measurement Accuracy: ±2 dB (<1.0 MHz offsets); ±4 dB (<100 MHz offsets) E5500 A-Series Optional Capabilities Extend offset range to 8, 10, and 100 MHz Add RF reference source Add high power input capability (includes juW phase and AM detectors) Extend carrier frequency to 110 GHz E5500 B-Series Optional Capabilities Add RF reference source Add high power input capability (includes juW phase and AM detectors) Add remote SCPI programming client Extend carrier frequency to 110 GHz 2 Without reference sources or downconverters Key Literature E5500 Series Phase Noise Measurement Solutions, Product Overview, p/n 5965-7590E E5500 Series Phase Noise Measurement Solutions Configuration Guide, p/n 5965-7589E Ordering Information E5500A Series E5500B Series See configuration guide for detailed ordering information. E5500 B-Series E5501B: 50 kHz to 1.6 GHz E5502B: 50 kHz to 6.0 GHz E5503B: 50 kHz to 18.0 GHz E5504B: 50 kHz to 26.5 GHz 341 E5500 Series 6 Internet URL Product & Order Info See page 604...

Este manual também é adequado para os modelos :
Acessórios de computador - E5500 B-series (200.98 kb)
Acessórios de computador - E5503A (200.98 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias