Log:
Assessments - 1, GPA: 4 ( )

Instruções de Operação Avenview, Modelo SPLIT-DVI-2

Fabricante : Avenview
Arquivo Tamanho: 636.03 kb
Arquivo Nome : SPLIT-DVI-2-UG.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


. Do not attempt to service this product yourself as opening or removing housing may expose you to dangerous voltage or other hazards . Keep the module away from liquids. . Spillage into the housing may result in fire, electrical shock, or equipment damage. If an object or liquid falls or spills on to the housing, unplug the module immediately. . Have the module checked by a qualified service engineer before using it again. . Do not use liquid or aerosol cleaners to clean this unit. Always unplug the power to the device before cleaning. 1.3 Regulatory Notices Federal Communications Commission (FCC) This equipment has been tested and found to comply with Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Any changes or modifications made to this equipment may void the user’s authority to operate this equipment. 1.4 Introduction Avenview SPLIT-DVI-2 Distribution System lets your one digital video signal (Set-Top boxes, DVD Player or PC) with DVI output and distributes it to two or more digital displays such as PC Monitor, HDTV, or Projector. - Supports both PC Monitor and HDTV display by function switch - Supports HDCP compliant device - Compatible with DVI Standard by DDWG - The use of standard DVI-D Plug - Support 480i, 480p, 720i, 720p, and 1080i resolution for HDTV - Supports up to WUXGA (1920 x 1200) resolution for Monitor - Connects two or more digital display at the same time from the same digital video source - Waiting Mode for Low Power (50mW) 1.5 Package Contents Before you start the installation of the converter, please check the package contents. - SPLIT-DVI-2 x 1 - Power Adapter (+5VDC) x 1 - User’s Manual x 1 1.6 Before Installation . Put the product in an even and stable location. If the product falls down or drops, it may cause an injury or malfunction. . Don’t place the product in too high temperature (over 50°C), too low temperature (under 0°C) or high humidity. . Use the DC power adapter with correct specifications. If inappropriate power supply is used then it may cause a fire. . Do not twist or pull by force ends of the optical cable. It can cause malfunction. 1.7 Installation The installation of SPLIT-DVI-2 is simple: 1. Power off display source such as DVD Player, Set-top box 2. Connect the DVI cable into each display source and display 3. Connect DVI cable which is attached to display source into SPLIT-DVI-2 4. Connect Power to SPLIT-DVI-2 5. For HDTV Signal select HDTV from Function Switch and for PC Signal select PC Section 2: Specifications Item Description Units SPLIT-DVI-2 Unit Description 2 Port DVI Splitter DVI Version 1.0 HDCP Compliance 1.1 Clock Frequency 25MHz – 225 MHz Supported Resolution & Distance Up to WUXGA 1920 x 1200 DVI Connector 29 pin DVI-D Plug Dimensions (L x W x H) 3.7” x 6.9” x 1” Power Supply 5V 2A DC Power Consumption 3W (max) Environmental Operating Temperature 32. ~ 104.F (0. to 40.C) Storage Temperature -4. ~ 140.F (-20. ~ 60.C) Relative Humidity 20~90% RH (no condensation) 2.1 Connector Pin Assignment TRANSMITTER Pin Signal Assignment Pin Signal Assignment Pin Signal Assignment 1 T.M.D.S. Data2- 9 T.M.D.S. Data1- 17 T.M.D.S. Data0- 2 T.M.D.S. Data2+ 10 T.M.D.S. Data1+ 18 T.M.D.S. Data0+ 3 T.M.D.S. Data2 Shield 11 T.M.D.S. Data1 Shield 19 T.M.D.S. Data0 Shield 4 No Connect 12 No Connect 20 No Connect 5 No Connect 13 No Connect 21 No Connect 6 SCL 14 +5V Power 22 T.M.D.S. Clock Shield 7 SDA 15 Ground 23 T.M.D.S. Clock+ 8 No Connect 16 Hot Plug Detect 24 T.M.D.S. Clock- RECEIVER Pin Signal Assignment Pin Signal Assignment Pin Signal Assignment 1 T.M.D.S. Data2- 9 T.M.D.S. Data1- 17 T.M.D.S. Data0- 2 T.M.D.S. Data2+ 10 T.M.D.S. Data1+ 18 T.M.D.S. Data0+ 3 T.M.D.S. Data2 Shield 11 T.M.D.S. Data1 Shield 19 T.M.D.S. Data0 Shield 4 No Connect 12 No Connect 20 No Connect 5 No Connect 13 No Connect 21 No Connect 6 DDC Clock (SCL) 14 +5V Power 22 T.M.D.S. Clock Shield 7 DDC Data (SDA) 15 Ground (for Out +5V) 23 T.M.D.S. Clock+ 8 No Connect 16 Hot Plug Detect 24 T.M.D.S. Clock- avenview-logo-whiteBG_Final.png Disclaimer While every precaution has been taken in the preparation of this document, Avenview Inc. assumes no liability with respect to the operation or use of Avenview hardware, software or other products and documentation described herein, for any act or omission of Avenview concerning such products or this documentation, for any interruption of service, loss or interruption of business, loss of anticipatory profits, or for punitive, incidental or consequential damages in connection with the furnishing, performance, or use of the Avenview hardware, software, or other products and documentation provided herein. Avenview Inc. reserves the right to make changes without further notice to a product or system described herein to improve reliability, function or design. With respect to Avenview products which this document relates, Avenview disclaims all express or implied...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias