• Connectors with 20 to 96 contacts are available for various purposes. • Discrete-wire (AWG #28, #30) I/O cables can be assembled by IDC. Metal covers completely protect sockets from EMI. • Bellows contacts ensure stable contact preventing pins from bending. The bellows contacts also have excellent stability with repeated insertion and extraction. • Tails are spaced in a four-row staggered arrangement (2.54 mm . 1.905 mm) (0.100 in. . 0.075 in.) for easy PC board design. • Insulation is UL-approved (94V-0) and is washable. • An FCN-230 EMI cover and dust cap can be used together. n SPECIFICATIONS n MATERIALS Item Specifications Operating temperature range –55°C to +105°C Current rating DC 1 A Voltage rating AC 240 V Contact resistance 35 mW max. (DC 6 V, 0.1A) Insulation resistance 1000 MW min. (DC 500 V) Dielectric withstand voltage AC 750 V for 1 minute Insertion force (kg) 4.5 kg max. (20 pins) Withdrawal force (kg) 0.6 kg min. (20 pins) Applicable PC board 1.6 mm (0.063 in.) thick Applicable wire (standard) IDC: AWG #28 and #30 stranded wires with f 0.5 to 0.88 mm (0.020 to 0.035 in.) insulation diameter. Soldering: AWG #26 max. (reference) (The applicable wires depend on the number of contacts. See the descriptions of IDC sockets and metal covers.) Item Materials Insulator Polyester (UL94V-0) Conductor Copper alloy Plating Contact Gold plating Terminal Palladium plating Specifications Dimensions are in millimeters (inches) subject to change 240 Series (General-Purpose Type) n ORDERING CODE FCN-24 5 P 050-G/ E E: Metal type Plating G: Gold plating Number of contacts: 20, 28, 36, 50, 68, 80, and 96 Soldering eyelet: 20, 28, 36, 50, and 96 Straight: 36 and 50 Body J: Socket P: Plug Tail type 4: Straight 5: Right-angle 7: Insulation displacement connection (IDC) socket 240 series connector Fujitsu connector n APPLICATIONS FCN-247J . . . -G/E (Socket body) FCN-230C . . . -A/E (Cover) FCN-245P . . . -G/E Docking Connectors FCN-245P 096 -G/E C630-5332-T748 Specifications Dimensions are in millimeters (inches) subject to change 240 Series (General-Purpose Type) STRAIGHT PLUG n DIMENSIONS Unit: mm (in.) A B CEnd terminal 10.5 (0.413)7.3(0.278) No. 1 No. 2 No. 3 D C 5.4(0.212) 0.4 (0.015) 5.6(0.220) 3.4(0.133) 1.905 (0.075) 1.27 (0.050) 1.27 (0.050) 2-M2.5(0.098) 0.3 (0.011) n MOUNTING HOLE LAYOUT B ± 0.1 (± 004) 1.905 ± 0.1 (0.075 ± 0.004) C ± 0.1 (± 004) 1.27 ± 0.1 (0.050 ± 0.004) End terminal f0.80±0.06 B ± 0.1 (± 004) C ± 0.1 (± 004) 1.27 ± 0.1 (0.050 ± 0.004) f0.80±0.06 No. 1 No. 2 No. 3 2-f2.8(0.110)1.905 ± 0.1 (0.075 ± 0.004) 2-f2.8(0.110)End terminal No. 1 No. 2 No. 3 36 and 96 contacts 50 contacts (Component side) Unit: mm (in.) n RECOMMENDED PANEL DIMENSIONS Unit: mm (in.) 8.3 ± 0.1 (0.326 ± 0.004) Recommended panel thickness t = 1 (D + 0.5) ± 0.1 ((D + 0.019) ± 0.004) B ± 0.1 (± 0.004) R 1.5 ± 0.1 (R 0.059± 0.004) n PART NUMBERS AND DIMENSIONS Number of Part number Dimensions: mm (in.) contacts A B C D 36 FCN-244P036-G/E 43.56 (1.714) 37.56 (1.478) 21.59 (0.850) 33.46 (1.317) 50 FCN-244P050-G/E 52.45 (2.064) 46.45 (1.828) 30.48 (1.200) 42.35 (1.607) 96 FCN-244P096-G/E 81.66 (3.214) 75.66 (2.978) 59.69 (2.350) 71.56 (2.817) Specifications Dimensions are in millimeters (inches) subject to change 240 Series (General-Purpose Type) RIGHT-ANGLE PLUG n DIMENSIONS A 10.5(0.413) B C 1.27 (0.050) 0.6 (0.023) End terminal 7.3(0.287) No. 1 No. 2 No. 3 2-M2.5(0.098) 11.8(0.464) D 6.705(0.263) 5.9(0.232) 2-M2.5 (0.098) 0.3 (0.011) 4.37 (0.172) 3.4 (0.133) 8.47 (0.333) 0.8 (0.31)4 (0.157) 1.905(0.075) Unit: mm (in.) n MOUNTING HOLE LAYOUT B ± 0.1 (± 0.004) C ± 0.1 (± 0.004) 1.27± 0.1 (0.050± 0.004) End terminal f0.80±0.06(0.031±0.002) B ± 0.1 (± 0.004) C ± 0.1 (± 0.004) 1.27± 0.1 (0.050± 0.004) f0.80±0.06(0.031±0.002) No. 1 No. 2 No. 3 2-f2.8(0.110) 3.7 mm(0.146 in.) min. 1.905 ± 0.1 (0.075 ± 0.004) 2-f2.8(0.110) 1.905 ± 0.1 (0.075 ± 0.004) 20, 28, 36, 68, 80 and 96 contacts No. 1 No. 2 No. 3 3.7 mm(0.146 in.) min. 50 contacts End terminal (Component side) Unit: mm (in.) n PANEL INHIBITED AREAS n RECOMMENDED PANEL DIMENSIONS 3.4 –0 (0.133 –0) 6.3 max.B ± 0.1 (± 0.004) 4.7 –0 (0.185 –0) 5.5 –0 (0.216 –0 ) 3.2 –0(0.125 –0 ) Unit: mm (0.141 max.) Recommended panel thickness t = 1 (D + 0.5) ± 0.1 ((D + 0.019) ± 0.004) B ± 0.1 (± 0.004) 8.3 ± 0.1 (0.326 ± 0.004) R 1.5 ± 0.1 (R 0.059± 0.004) Unit: mm (in.) n PART NUMBERS AND DIMENSIONS Number of Part number Dimensions: mm (in.) contacts A B C D 20 FCN-245P020-G/E 33.40 (1.314) 27.40 (1.078) 11.43 (0.450) 23.30 (0.917) 28 FCN-245P028-G/E 38.48 (1.514) 32.48 (1.278) 16.51 (0.650) 28.38 (1.117) 36 FCN-245P036-G/E 43.56 (1.714) 37.56 (1.478) 21.59 (0.850) 33.46 (1.317) 50 FCN-245P050-G/E 52.45 (2.064) 46.45 (1.828) 30.48 (1.200) 42.35 (1.667) 68 FCN-245P068-G/E 63.88 (2.514) 57.88 (2.278) 41.91 (1.650) 53.78 (2.117) 80 FCN-245P080-G/E 71.50 (2.814) 65.50 (2.578) 49.53 (1.950) 61.40 (2.417) 96 FCN-245P096-G/E 81.6...
Escreva a sua própria avaliação do dispositivo
|
|