Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação Field, Modelo FS-RA-CLX-FIR

Fabricante : Field
Arquivo Tamanho: 468.6 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


2.7 Change the Configuration File to Meet the Application FieldServer Technologies offers training on this topic as well as a configuration service to complete this portion of the work. See for specific details. . Refer to the FieldServer Configuration Manual for instruction on writing a FieldServer configuration. . Refer to the SlotServer Configuration Manual for assistance on managing the Logix driver Parameters . Refer to the desired protocol Driver Supplement for assistance on managing the protocol parameters. 2.8 Download the Updated Configuration File Before attempting to send files to the SlotServer, ensure that the files are in the configuration file folder. Refer to the FieldServer Utilities manual for further information. . From the main menu, type "D" to access the “download” menu, . Type "L" (for local filename) to specify the name and extension of the file to be sent to the SlotServer. Hit when done. . The Remote User Interface Utility will automatically select config.csv for download of csv files. On rare occasions where other files need to be downloaded to the SlotServer type “O” for other files, then type “R” to specify the remote filename needed on the SlotServer. . When satisfied that the correct file names are specified, Type "D" to download the file to the SlotServer. The Remote User Interface Utility will display a menu showing download progress. Note: the Remote User Interface Utility will indicate when download is complete. DO NOT reset the SlotServer before this message displays, as this could corrupt the SlotServer. . Once download is complete, hit to get back to the main menu and use the "!" option (or simply cycle power to the SlotServer) to put the new file into operation. Note that it is possible to do multiple downloads to the SlotServer before resetting it. . Firmware created by FieldServer Technologies can be downloaded from the configuration file by simply typing “F” from the download menu. Note that FieldServer usually supplies firmware upgrades as an install.zip, for which a separate procedure is used, (See ENote 037 on the USB flash drive in a folder called Library. 2.9 Test and commission the SlotServer Connect the SlotServer to the third party devices, and test the application. ProSoft Technology, Inc. is the exclusive provider of FieldServer SlotServers. For Technical Support call +1 661.716.5100 SlotServer Start-Up Guide Page 8 of 12 Appendix A. Useful Features Refer to the Configuration Manual for useful configuration features. The unit may be removed under power for convenient swapping of modules. Appendix A.1. LED Functions RunNode OffSys ErrLonSvcConf ErrCom ErrRxTxService PinThe LonWorks Service pin can be used for commissioning the SlotServer into a LonWorks network. LonWorks Activity can be determined using this LED as follows: LON LED Activity Explicit Implicit –Not Commissioned Implicit – Commissioned Off Flashing Off Figure 3: Diagram of SlotServer showing ports and displays LED Description Run When the SlotServer is powered up, this light will start flashing after approximately 2 minutes. If this light does not flash, it is an indication that the firmware is not running, and that the SlotServer will not be operating. LonSvc This LED indicates LonWorks activity. Refer to Figure 3. NodeOff This light indicates that a device bound to the SlotServer on the LonWorks network is not communicating. Use the LonWorks Network Manager to troubleshoot the problem. Conf Err This light indicates an error in the configuration of the card. Since this model is shipped pre-configured, this light should never come on unless the card configuration is tampered with Sys Err This light indicates that an unexpected operation state occurred. The light can be reset by cycling power to the card. If the error re-occurs persistently, then contact FieldServer Technical support for assistance with troubleshooting after setting up the trade port as shown in Appendix A. Com Err This light indicates that a communication error occurred. Use the LonWorks Network Manager to troubleshoot the problem, or refer to the SlotServer configuration Manual. RS-485 (R1) These lights are related to the RS-485 serial ports provided on the SlotServer. The Rx (Receive) light will flash red if the FieldServer is receiving data. The Tx (Transmit) light will flash red if the FieldServer is sending data. (Note that due to the nature of 2-wire RS-485 the Rx light will flash every time the Tx light flashes too). The frequency of the flashing is directly related to the frequency of data transfer. Ethernet Lights 10/100 Act These lights are related to the Ethernet network ports provided on the SlotServer. The 10/100 light will be green if the physical connection to the network hub is running at 100 MBits/s. If the light is off, the connection is running at 10 MBits/s. The Act (Activity) light will indicate activity on the network. The frequency of flashing is directly related to the ...

Este manual também é adequado para os modelos :
Computadores - FS-RA-CLX-PRO (468.6 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias