Log:
Assessments - 4, GPA: 3.8 ( )

Instruções de Operação Field, Modelo SIEMENS TIWAY I FS-8700-31

Fabricante : Field
Arquivo Tamanho: 170.38 kb
Arquivo Nome : d6faa6be-1d6c-46f6-ab29-188c1dcb57c6.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Driver Scope of Supply.....................................................................................................2 2.1. Supplied by FieldServer Technologies for this driver ...................................................2 2.2. Provided by the Supplier of 3rd Party Equipment..........................................................2 2.2.1. Hardware...................................................................................................................2 2.2.2. Required 3rd Party Software......................................................................................2 2.2.3. Required 3rd Party Configuration...............................................................................2 2.2.4. Optional Items...........................................................................................................2 3. Hardware Connections.....................................................................................................3 3.1. Hardware Connection Tips / Hints................................................................................3 4. Configuring the FieldServer as a TIWAY Client .............................................................3 4.1. Data Arrays/Descriptors ...............................................................................................3 4.2. Client Side Connection Descriptions ............................................................................4 4.3. Client Side Node Descriptors .......................................................................................5 4.4. Client Side Map Descriptors.........................................................................................5 4.4.1. FieldServer Related Map Descriptor Parameters......................................................5 4.4.2. Driver Related Map Descriptor Parameters ..............................................................6 4.4.3. Timing Parameters....................................................................................................7 4.4.4. Reading TIWAY data map descriptor examples .......................................................8 4.4.4.1. Reading data from contiguous PLC data memory locations...............................8 4.4.4.2. Reading data from random PLC data memory locations....................................8 4.4.4.3. Reading Drum_Count_Preset data from contiguous PLC data memory locations 8 4.4.4.4. Reading Drum_Count_Preset data from random PLC data memory locations..9 4.4.4.5. Reading secondary PLC status ..........................................................................9 4.4.5. Writing TIWAY data map descriptor examples........................................................10 4.4.5.1. Writing data to contiguous PLC data memory locations...................................10 4.4.5.2. Writing data to random PLC data memory locations ........................................10 4.4.5.3. Writing the same value to a block of contiguous PLC data memory locations .11 4.4.5.4. Writing Drum_Count_Preset data to contiguous PLC data memory locations .11 4.4.5.5. Writing Drum_Count_Preset data to random PLC data memory locations.......11 4.4.6. TIWAY host adapter command map descriptor examples......................................12 4.4.6.1. Read Secondary Log........................................................................................12 4.4.6.2. Report HIU Configuration .................................................................................12 4.4.6.3. Report Adapter Configuration...........................................................................13 4.4.6.4. Report Network Manager Configuration ...........................................................13 4.4.6.5. Soft Reset.........................................................................................................14 4.4.6.6. Reset Adapter...................................................................................................15 4.4.6.7. Disconnect Secondaries...................................................................................15 4.4.6.8. Connect Secondaries .......................................................................................15 5. Configuring the FieldServer as a TIWAY Server..........................................................17 5.1. Server Side Connection Descriptors...........................................................................17 5.2. Server Side Node Descriptors....................................................................................18 FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldserver.com FS-8700-31 Siemens TIWAY I Index 5.3. Server Side Map Descriptors......................................................................................19 5.3.1. FieldServer Specific Map Descriptor Parameters ........................


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias