Log:
Assessments - 2, GPA: 4 ( )

Instruções de Operação Dell, Modelo PRIMERGY BX600 S3

Fabricante : Dell
Arquivo Tamanho: 4.01 mb
Arquivo Nome : bx600s3-zbox-en.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


– Local installation with or without ServerView Installation Manager Since the local installation is the least convenient installation method, it is only recommended if the requirements for remote installation or cloning are not satisfied. If you wish to install an operating system that is not supported by Server- View Installation Manager, you can perform the installation directly without using ServerView Installation Manager. I For further information on remote or local installation of server blades, please see the ServerView Installation Manager manual, which contains a “Quick Step Guide” as well as a detailed description of the different installation options and installation wizards. A print version of the ServerView Installation Manager manual is included in the PRIMERGY ServerView Suite, which comes with the BX600 S3 basic unit. A PDF version of the manual is contained on the PRIMERGY ServerBooks DVD. Cloning of server blades is described in the RemoteDeploy manual (print version delivered with RemoteDeploy, PDF version contained on the PRIMERGY ServerBooks DVD). 20 Operating Manual BX600 S3 3 Important Notes In this chapter you will find essential information on safety when working with your system. 3.1 Notes on Safety I You will also find the following safety instructions in the manual entitled “Safety“, which also includes additional notes on the guarantee and ergonomics. This device complies with the relevant safety regulations for data processing equipment, including electronic office machines for use in an office environment. If you have any questions, please contact your sales outlet or the customer service center of Fujitsu Technology Solutions. V CAUTION! The actions described in these instructions should only be performed by technicians, service personnel or technical specialists. Equipment repairs should only be performed by qualified staff. Any failure to observe the guidelines in this manual could expose the user to risks (electric shock, fire hazards) and could also damage the equipment. Note that any unauthorized opening of the device will result in the invalidation of the warranty and exclusion from all liability. BX600 S3 Operating Manual Notes on Safety Important Notes Before Setting Up V CAUTION! . During installation and before operating the device, observe the instructions on environmental conditions for your device in the section “Technical Data” on page 16. . If the device is brought in from a cold environment, condensation may form on both the inside and outside of the machine. Before operating the device, wait until it is absolutely dry and has reached approximately the same temperature as the installation site. Failure to observe these guidelines can lead to physical damage of the device. . Transport the device only in the original packaging or in packaging which protects it from knocks and jolts. Installation and Operation V CAUTION! . For safety reasons, make sure you read any warning labels when removing modules from the server. . Beware of energy hazards on the plug-in contacts of the midplane. A short circuit on these connections can lead to damage to the system. . If the server is integrated in a (rack) installation that receives power from an industrial (public) power supply network with the IEC309 connector, the (public) power supply protection must comply with the requirements for the non-industrial (public) power supply networks for the type-A connector. . For the PRIMERGY BX600 S3 unit only 2100W PSUs are allowed (Product no. A3C40073262)! The 1200W PSUs of the PRIMERGY BX600 S1 basic unit is not allowed for the PRIMERGY BX600 S3 basic unit. The 2100W PSU is not allowed for the PRIMERGY BX600 S1 basic unit. 22 Operating Manual BX600 S3 Important Notes Notes on Safety V CAUTION! . Due to the high power requirements of the BX600 S3 blade server, you must be careful when arranging the power cabling. Please notice the information that purpose in section “Notes on power cabling” on page 126). . Make sure that the PRIMERGY BX600 S3 basic unit is connected to the mains for at least one minute before pressing the power ON/OFF button to switch the system ON. . The server automatically adjusts to a mains voltage of 200 -240 V. The server may only be put into operation if the mains voltage range set on the server corresponds to the local mains voltage. . This device has safety-tested power cables and must only be connected to properly grounded power sockets or CEE sockets. . The power button does not disconnect the device from the mains voltage. To completely disconnect it from the mains voltage, the power plugs must be removed from the power socket. . Data transmission cables must not be connected or disconnected during a thunderstorm (lightning hazard). . Make sure that no objects (such as bracelets or paper clips) or liquids fall/spill into the device (risk of electric shock or short circuit). . Data cables must be adequately shielded to avoid interference. . The LAN wirin...

Este manual também é adequado para os modelos :
Computadores - PRIMERGY BX600 S3 (4.01 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias