Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação HP, Modelo HP Integrity rx6600 Server

Fabricante : HP
Arquivo Tamanho: 258.54 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


Presenting LUNs to a Linux host
When presenting XP LUNs to a Linux host:

The LUNs must start with a LUN 0.

The LUNs must be presented across all paths that are connected or configured from the XP
storage array.

If LUN 0 is not present, SANsurfer displays the XP array as offline.
Dynamic target addition not supported for XP arrays
Dynamic target addition is defined as adding a new Fibre Channel target (such as adding a new
storage array) to a SAN, presenting that new target to a Fibre Channel host bus adapter, and then
prompting the operating system to do an online scan (such as using the hp_rescan utility that
comes with fibreutils). This functionality is not supported with XP arrays. If a new Fibre Channel XP
target is added to a host server, it is necessary to reboot that host server.
For 81Q and 82Q only
HP Simple SAN Connection Manager (SSCM) is supported on the Windows based management
server and connects to the qlremote agent on the Linux server.
Windows important notes
This section describes restrictions and notes for QLogic adapters installed on servers running
Windows.
ProLiant servers running Windows notes
HBA restrictions for ProLiant servers running Windows are as follows:

SANsurfer restrictions:

HBA port cannot be disabled using Windows Device Manager when the SANsurfer agent
is running. To disable the HBA port, stop the SANsurfer agent in the services window or
uninstall SANsurfer first.

The EVA firmware version displayed in SANsurfer might be incorrect. When an EVA is
configured in Windows host mode, the standard Inquiry data returns a constant EVA
firmware version number. Obtain the correct EVA firmware version using HP P6000
Command View or HP Command View EVA.

The HBA VPD data displayed in SANsurfer can be incorrect in an IA64 EFI or IA64
Windows environment. If this occurs, update a QLogic multiboot package with SANsurfer
in a Windows IA64 operating system. Repeat this step a second time.

On a Windows server, SCSIport and STORport miniport drivers can be used for HBAs from
different vendors. However, on that server, all HBAs from a single vendor must operate
exclusively with either all SCSIport miniport drivers or all STORport miniport drivers.
Booting from a SAN installation with QMH2462 on Microsoft Windows 2008 SP2
Booting from a SAN installation of Microsoft Windows 2008 SP2 using the QLogic QMH2462
Mezzanine Card may not succeed if attempting to perform the O/S deployment by using driver
files obtained from the HP QLogic driver Smart Component. A blue screen might be observed
along with a message stating “The system has halted.”
To boot from a SAN installation of Microsoft Windows 2008 SP2 with the QLogic QMH2462,
perform the initial O/S installation using the Windows in-box driver (included with the O/S), and
then update to the latest HP supported driver after rebooting.
Important notes
9


...

Este manual também é adequado para os modelos :
Computadores - HP Integrity Superdome sx2000 Server (258.54 kb)
Computadores - HP Integrity rx7640 Server (258.54 kb)
Computadores - HP Integrity rx8640 Server (258.54 kb)
Software - Microsoft Windows Server 2008 for Itanium-based Systems (258.54 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias