Log:
Assessments - 5, GPA: 4.4 ( )

Instruções de Operação Fujitsu, Modelo BX900 S1

Fabricante : Fujitsu
Arquivo Tamanho: 4.89 mb
Arquivo Nome : 703e0f81-20da-4bc2-8402-df937dcf3f5d.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Is not lit when the management blade is not active (slave) 2 LAN activity indicator (service LAN connection) Lights up green if a LAN connection exists. Does not light up if no LAN connection exists. Flashes orange when a LAN transfer is in progress. 3 LAN transfer-rate indicator (service LAN port) Lights up green for a LAN transfer rate of 100 Mbit/s. Does not light up for a LAN transfer rate of 10 Mbit/s. BX900 S1 Operating Manual Installation and operation 4 Global Error indicator (orange) – Lights up orange if a prefailure event has been detected that requires (precautionary) service intervention. – Flashes orange if an error was detected that requires service intervention. – Does not light up if there is no critical event. If the event is still acute after a power failure, the indicator is activated after the restart. The indicator also lights up in standby mode. You can find more details on the indicated errors in the System Event Log (SEL), , in the Management Blade Web interface, on the ServerView Local Service Panel, on the ServerView Local Service Display, in the ServerView Operations Manager or via the iRMC S2's Web interface. 5 CSS indicator (yellow) – Lights up yellow if a prefailure event was detected for a CSS component that you can fix yourself (for reasons of precaution) with the CSS concept. – Flashes yellow if an error was detected that you can fix yourself with the CSS concept. – Does not light up when the system is OK. If the event is still acute after a power failure, the indicator is activated after the restart. The indicator also lights up in standby mode. For more information on the CSS concept, see "Customer Self Service (CSS)" on page 13. 6 Identification (ID) button with ID LED (blue) ID indicators on the front and rear of the server light up when the ID button is pressed. The two ID indicators are synchronized. To deactivate, press the button again. The ID indicator can also be activated via ServerView Operations Manager and the Management Blade Web interface; its status is reported to ServerView Operations Manager and the Management Blade. 64 Operating Manual BX900 S1 Installation and operation 7, 9 LAN activity indicator (Management LAN ports) Lights up green if a LAN connection exists. Does not light up if no LAN connection exists. Flashes orange when a LAN transfer is in progress. 8, 10 LAN transfer-rate indicator (Management LAN ports) Lights yellow for a LAN transfer rate of 1 Gbit/s. Lights up orange for a LAN transfer rate of 100 Mbit/s. Does not light up for a LAN transfer rate of 10 Mbit/s. 11 Hidden reset button BX900 S1 Operating Manual Installation and operation 5.1.2.2 Indicators on the hot-plug power supply units 1 2 3 Figure 16: Indicators on the hot-plug power supply unit 1 Error indicator for fan module 1 (orange) Lights up if fan module 1 is defective. 2 Mains power indicator (two-color) Flashes green when the system unit is switched off but still connected to the mains (standby mode). Lights up green when the system unit is switched on and is working properly. Lights up yellow when a prospective error has been detected in the power supply unit but the latter is still active.* 3 Error indicator for fan module 2 (orange) Lights up if fan module 2 is defective. * The following events are detected as predictable errors: The temperature is very high. The power consumption is very high. The current strength is very high. 66 Operating Manual BX900 S1 Installation and operation 5.1.2.3 Indicators on the hot-plug fans 1 2 3 Figure 17: Indicators on the hot-plug fan module 1 Error indicator for fan module 1 (orange) Lights up if fan module 1 is defective. 2 Power indicator Flashes green when the system unit is switched off but still connected to the mains (standby mode). Lights up green when the system unit is switched on and the fan module is working properly. 3 Error indicator for fan module 2 (orange) Lights up if fan module 2 is defective. BX900 S1 Operating Manual Installation and operation 5.2 Switching the system unit on/off V CAUTION! . Before switching the system unit on using the On/Off button, the PRIMERGY BX900 S1 system unit must be connected to the power supply for at least a minute. . If you switch on the system unit and the connected monitor only shows flickering stripes, switch it back off immediately (see chapter "Troubleshooting and tips" on page 77). . The On/Off button does not disconnect the device from the mains. To fully disconnect it from the mains, you must unplug the plugs from the sockets. . Turn the server on when the temperature is in its operating environment range (10–35°C). For details on the operating environment, refer to "Safety Precautions". When operating the device outside of this operating environment, the server may operate improperly, damage data etc. Furthermore, Fujitsu cannot be held responsible for any related damage, malfunction, or loss of data, etc. . Be sure to wait for 10 seconds or more after shutdown before turning t...

Este manual também é adequado para os modelos :
Computadores - BX900 S1 (4.89 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias