Fabricante : Kenmore
Arquivo Tamanho: 7.66 mb
Arquivo Nome : s_te9_12dke.pdf
|
Facilidade de uso
RAC0502005C2 Service Manual Air Conditioner CS-TE9DKE CU-TE9DKE CS-TE12DKE CU-TE12DKE ссюш i|S î • A WARNING This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product. Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service or repair the product or products dealt with in this service information by anyone else could result in serious injury or death. A PRECAUTION OF LOW TEMPERATURE In order to avoid frostbite, be assured of no refrigerant leakage during the installation or repairing of refrigeration circuit. CONTENTS Page 1 Features..................................................................................2 2 Functions................................................................................3 2.1. Remote Control.............................................................3 2.2. Indoor Unit....................................................................4 2.3. Outdoor unit..................................................................5 3 Product Specifications...........................................................6 4 Dimensions...........................................................................10 4.1. Indoor Unit...................................................................10 4.2. Outdoor Unit................................................................11 5 Refrigeration Cycle Diagram.................................................12 6 Block Diagram......................................................................13 7 Wiring Diagram.....................................................................14 7.1. CS-TE9DTE / CS-TE12DKE.........................................14 Page 7.2. CU-TE9DKE / CU-TE12DKE........................................15 8 Electronic Circuit Diagram....................................................16 8.1. Indoor Unit / Remote Controller....................................16 8.2. Outdoor Unit................................................................18 9 Operation Details..................................................................20 9.1. BASIC FUNCTION.......................................................20 9.2. Indoor Power Relay Control..........................................21 9.3. Room Air Temperature Control (Compressor Control)--21 9.4. Airflow Direction Control...............................................23 9.5. Quiet operation (Cooling Mode / Cooling area of Dry Mode)..........................................................................24 9.6. Indoor Fan Control.......................................................26 9.7. Powerful Operation......................................................29 Panasonic © 2005 Matsushita Electric Industrial Co., Ltd. All rights reserved. Unauthorized copying and distribution is a violation of law. CS-TE9DKE CU-TE9DKE / CS-TE12DKE CU-TE12DKE 9.8. Automatic Operation....................................................30 9.9. Timer Operation (24H Real Timer)................................31 9.10. Auto Restart Control.....................................................31 9.11. Ionizer Operation.........................................................32 9.12. Protection Control........................................................33 10 Operating Instructions............-...............-.............................34 11 Installation Instructions........................................................40 11.1. SAFETY PRECAUTIONS.............................................40 11.2. INDOOR UNIT.............................................................43 11.3. OUTDOOR UNIT.........................................................46 12 Installation and Servicing Air Conditioner Using R410A......49 12.1. OUTLINE.....................................................................49 12.2. TOOLS FOR INSTALLING/SERVICING REFRIGERANT PIPING........................................................................50 12.3. REFRIGERANT PIPING WORK...................................54 1 Features • Product -Microcomputer-controlled compressor operating frequency. - Vertical airflow direction. - Four modes of operation selection. -Air filter with function to reduce dust and smoke. - SUPER Alleru-buster filter inactive various harmful airborne elements including allergens, viruses and bacteria. - Ionizer control for generate negative ion in discharge air. - Quiet mode to provide quiet operation. - 24-hour timer setting. - Long installation piping up to 15 meters. • Quality Improvement - Random auto restart after power failure for safety restart operation. - Gas leakage detection. 12.4. INSTALLATION, TRANSFERRING, SERVICING...........57 13 Servicing I...
Este manual também é adequado para os modelos :Aparelhos de ar condicionado - CS-TE9DKE (7.66 mb)