Log:
Assessments - 2, GPA: 3 ( )

Instruções de Operação Hitachi, Modelo RAS-80YHA

Fabricante : Hitachi
Arquivo Tamanho: 1.36 mb
Arquivo Nome : ccd254a5-0d3c-4538-8b88-db85cec082b6.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


The lamp goes out when the “ (AUTO SWING)” button is pressed while the device is on “STANDBY MODE”. – 5 – NAMES AND FUNCTIONS OF EACH PART REMOTE CONTROLLER This controls the operation of the indoor unit. The range of control is about 7 meters. If indoor lighting is controlled electronically, the range of control may be shorter. This unit can be fixed on a wall using the fixture provided. Before fixing it, make sure the indoor unit can be controlled from the remote controller. Signal emitting window/transmission sign Point this window toward the indoor unit when controlling it. The transmission sign blinks when a signal is sent. Display This indicates the room temperature selected, current time, timer status, function and intensity of circulation selected. START/STOP button Press this button to start operation. Press it again to stop operation. FAN SPEED selector This determines the fan speed. Every time you press this button, the intensity Controls the angle of the horizontal air deflector. TEMPERATURE buttons Use these buttons to raise or lower the temperature setting. (Keep pressed, and the value will change more quickly.) SLEEP button Use this button to set the sleep timer. TIME button Use this button to set and check the time and date. RESET buttons FUNCTION selector Use this button to select the operating mode. Every time you press it, the mode will change from (AUTO) to (HEAT) to (DEHUMIDIFY) to (COOL) and to (FAN) cyclically. PARALLEL SWING button Controls the angle of the vertical air deflectors to parallel. SYMMETRY SWING button Controls the angle of the vertical air deflectors to symmetry. TIMER control Use this button to set the timer. OFF-TIMER button Select the turn OFF time. ON-TIMER button Select the turn ON time. RESERVE button Time setting reservation. CANCEL button Cancel time reservation. of circulation will change from (AUTO) to (HI) to (MED) to (LOW) (during the (FAN) mode, from HI to MED to LOW). AUTO SWING button Precautions for Use . Do not put the remote controller in the following places. . In direct sunlight. . In the vicinity of a heater. . Handle the remote controller carefully. Do not drop it on the floor, and protect it from water. . Once the outdoor unit stops, it will not restart for about 3 minutes (unless you turn the power switch off and on or unplug the power cord and plug it in again). This is to protect the device and does not indicate a failure. . If you press the FUNCTION selector button during operation, the device may stop for about 3 minutes for protection. – 6 – VARIOUS FUNCTIONS Auto Restart Control . If there is a power failure, operation will be automatically restarted when the power is resumed with previous operation mode and airflow direction. (As the operation is not stopped by remote controller.) . If you intend not to continue the operation when the power is resumed, switch off the power supply. When you switch on the circuit breaker, the operation will be automatically restarted with previous operation mode and airflow direction. Note: 1. If you do not require Auto Restart Control, please consult your sales agent or OFF by remote control. 2. Auto Restart Control is not available when Timer or Sleep Timer mode is set. AUTOMATIC OPERATION The device will automatically determine the mode of operation, HEAT, COOL or DEHUMIDIFY depending on the current room temperature. The selected mode of operation will change when the room temperature varies. RESET Over 27°C COOL 23~27°C Under 23°C HEAT Temperature settingFunction 27°C 23°C Slightly lower than the room temperature LOW FAN SPEED HI at start, MED or LOW after the preset temperature is reached HI at start, MED or LOW after the preset temperature is reached - - DEHUMIDIFY- Initial room temperature (approx.) Condition of Automatic Operation As the settings are stored in memory in the remote controller, you only have to press the (START/STOP) button next time. Press the FUNCTION selector so that the display indicates the (AUTO) mode of operation. When AUTO has been selected, the device will automatically determine the mode of operation, HEAT, COOL or DEHUMIDIFY depending on the current room temperature. If the mode automatically selected by the unit is not satisfactory, manually change the mode setting (heat, dehumidify, cool or fan). Press the (START/STOP) button. Operation starts with a beep. Press the button again to stop operation. You can raise or lower the temperature setting as necessary by maximum of 3°C. Press the temperature button and the temperature setting will change by 1°C each time. The preset temperature and the actual room temperature may vary somewhat depending on conditions. The display does not indicate the preset temperature in the AUTO mode. If you change the setting, the indoor unit will produce a beep. 1 START STOP °C Press the (FAN SPEED) button, AUTO and LOW is available. – 7 – HEATING OPERATION . Use the device for heating when the outdoor temperature is under 21°C. When it is too ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias