Log:
Assessments - 2, GPA: 4 ( )

Instruções de Operação Mitsubishi Electronics, Modelo MSZ-FA25VA

Fabricante : Mitsubishi Electronics
Arquivo Tamanho: 1.98 mb
Arquivo Nome : 92_manual_innedel_msz-fa25vah.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


TECHNICAL CHANGES ····································2 2. PART NAMES AND FUNCTIONS······················3 3. SPECIFICATION·················································5 4. NOISE CRITERIA CURVES ·······························6 AND DIMENSIONS ·························7 ············································8 7. REFRIGERANT SYSTEM DIAGRAM ················8 VICE FUNCTIONS ······································9 9. TROUBLESHOOTING······································11 INSTRUCTIONS·····················31 ······················································35 ···········································38 Indication of model name MSZ-FA25VA - MSZ-FA35VA -E1 E1 NOTE: This service manual describes technical data of the indoor units. •As for outdoor units MUZ-FA25VA-, MUZ-FA35VA-, MUZ-FA25VAH-and MUZ-FA35VAH-, refer to service manual OB372. •As for outdoor units MXZ-3A54VA-, MXZ-4A71VA-and MXZ-4A80VA-, refer to service manual OB377. E1E1E1 E1 E1E1E1 1 TECHNICAL CHANGES E1 E1 MSZ-A09YV O MSZ-FA25VA MSZ- A12YV -E1 O MSZ-FA35VA -E1 1. Indication of capacity has been changed.(BTU base O kW base) 2. Controller method between indoor and outdoor has been changed. 3. Power supply method has been changed (change to supply from outdoor unit). 4. Power supply cord has been removed. 5. Indoor electronic control P.C. board has been changed. 6. Position of terminal block has been changed. 7. Indoor fan motor has been changed. ( AC O DC) 8. Indoor heat exchanger has been changed. 9. The horizontal vane motor unit has been changed. An external gear is added to the generalized stepping motor. The unit is structured so that the driving torque and stopping torque would increase. Generalized stepping motor NOTE: Do not remove the vane motor from the motor unit. Do not disassemble the horizontal vane motor unit. 10. The vertical vane motor unit has been added. An external gear is added to the generalized stepping motor. The unit is structured so that the driving torque and stopping torque would increase. Generalized stepping motor NOTE: Do not remove the vane motor from the motor unit. Do not disassemble the vertical vane motor unit. 11. Front panel driving motor unit which opens and closes the front panel has been added. Front panel opening/closing output gear NOTE: Do not disassemble the front panel driving motor unit. 12. PLASMA DEODORIZING/AIR PURIFYING filter units have been added. 13. i-see Sensor has been added. (i-see control operation and AREA setting have been added.) 14. Air cleaning filer has been removed. 15. Signal of remote controller has been changed. (It is not available for the conventional models.) 16. Symbol on terminal block has been changed (to S1/S2/S3). 2 2 PART NAMES AND FUNCTIONS INDOOR UNIT MSZ-FA25VA - MSZ-FA35VA -E1 E1 Line flow fan Air outlet Vertical vane Air inlet Display section Front panel PLASMA DEODORIZING filterPanel Heat exchanger Horizontal vane Operation section (When the front panel is opened) Remote controller POWER lamp Remote control receiving section PLASMA AIR PURIFYING filter Anti-mold air filter Fan guard i-see Sensor PLASMA/WASH lamp AREA lamp Emergency operation switch WASH reset switch Auto front panel When the unit starts operating, the front panel opens automatically to draw in air. When the unit stops operating, the front panel closes automatically. Auto front panel AREA lamp indicate AREA setting In AREA setting, the horizontal air flow direction changes automatically according to the detection of i-see Sensor which detects the floor/ wall temperature to air-condition the room evenly. i-see control operation i-see sensor constantly measurefloor/wall temperature to automaticallyadjust to the set temperature byestimating the temperatureactually perceived by aperson inside the room("sensible temperature"). 3 E1 MSZ-FA25VA -E1 MSZ-FA35VA ACCESSORIES MSZ-FA25VA MSZ- FA35VA E1 E1 1Installation plate 1 2Installation plate fixing screw 4 o 25 mm 5 3Remote controller holder 1 4Fixing screw for 3 3.5 o 1.6 mm (Black) 2 5Battery (AAA) for remote controller 2 6Wireless remote controller 1 7Felt tape (Used for left or left-rear piping) 1 REMOTE CONTROLLER 4 ON-TIMER button CLOCK SET button TIME SET buttons FORWARD button BACKWARD button VANE CONTROL button (Horizontal vane button) OFF-TIMER button i-see button Open the front lid. PLASMA button AREA button RESET button WIDE VANE button (Vertical vane button) Signal transmitting section Operation display section Temperature buttons OPERATE/STOP (ON/OFF) button FAN SPEED CONTROL button OPERATION SELECT button ECONO COOL button Indication of remote controller model is on back SPECIFICATION 3 Indoor model MSZ-FA25VA - E1 MSZ-FA35VA - E1 Function Cooling Heating Cooling Heating Power supply Single phase 230V,50Hz Single phase 230V,50Hz Capacity Air flow(Super High) K /h 594 612 594 612 Air flow(HighW/Med.W/LowW) K /h 474W/354W/252W 498W/384W/264W 474W/354W/258W 498W/384W/276W Electricaldata Power outlet A 10 10 Running cu...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias