Log:
Assessments - 2, GPA: 4.5 ( )

Instruções de Operação Bard, Modelo 357-93-E

Fabricante : Bard
Arquivo Tamanho: 321.59 kb
Arquivo Nome : aaa30d3b-a72c-46a9-b640-86134bb2df9a.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


compressor, electric heat strip and electrical controls) when two units are mounted side by side with minimal space between. The left side unit is the ideal product for telecommunication and over-the-road medical and communication vans requiring two wall-mount air conditioners be mounted side by side by using a WL (left side access) unit and a WA (right side access) unit on the same building. Factory or field installed accessories are also available to meet specific job requirements. Engineered Features Aluminum Finned Copper Coils: Grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency. Twin Blowers: Move air quietly. Most models feature multispeed blower motors providing airflow adjustment for high and low static operation. Motor overload protection is standard on all models. Air Conditioner Compressor: Reciprocating compressors with crankcase heater and dual discharge muffler are standard on 1.5 and 2 ton models. Scroll Compressors eliminate need for crankcase heater. Standard on 2.5 to 5 ton, and available on 2 ton models. Phase Rotation Monitor: Standard on all 3 phase scroll compressors. Protects against reverse rotation if power supply is not properly connected. Not required on reciprocating compressors. Galvanized 20 Gauge Zinc Coated Steel Cabinet: Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on textured enamel, which allows it to withstand 1000 hours of salt spray tests per ASTM B117-03. Electrical Components: Are easily accessible for routine inspection and maintenance through a left side, service panel opening. Features a lockable, hinged access cover to the circuit breaker or pull disconnect switch. Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory installed for all 1.5 through 6 ton models. One Inch, Disposable Air Filters: Are standard equipment. Optional one inch washable filters available and filter racks permit the addition of 2" pleated filter. Factory or field installed. Built-in Circuit Breakers: Standard on all single (230/208 volt) and three phase (230/208 volt) equipment. Toggle disconnects are standard on all three phase (460 volt) equipment. Slope Top: Standard feature for water run-off. Top Rain Flashing: Standard feature on all models. Full Length Mounting Brackets: Built into cabinet for improved appearance and easy installation. NOTE: Bottom mounting bracket included to assist in installation. Auto-Reset High Pressure Switch: Built-in lock-out circuit resets from the room thermostat. Provides commercial quality protection to the compressor. Auto-Reset Low Pressure Switch: Built-in lock-out circuit and low pressure timed bypass circuit. Resets from room thermostat. Compressor Control Module: Built-in off-delay timer adjustable from 30 second to 5-minutes. 2-minute on-delay if power interrupt. 120-second bypass for low pressure control, and both soft and manual lockouts for high and low pressure controls. Alarm output for alarm relay. Low Ambient Control: Permits cooling operation down to 0°F outdoor ambient. Alarm Relay: Dry contacts for remote alarm capability on manual high or low pressure controls. MEA# 357-93-E Ventilation System Packages All packages are designed Standard - Barometric to meet your specific Fresh Air Damper ventilation requirements Optional - Motorized utilizing one of five Fresh Air Damper ventilation options for the product. The ventilation Optional - Blank off Plate package is mounted within Optional - Commercial the unit eliminating the need Room Ventilator with Exhaust for an exterior mounted • CRV - Spring Return hood or damper assembly • CRVP - Power Return on the unit. All assemblies can be factory installed, Optional - Economizer w/Exhaust installed in the field at time of installation or as a retrofit system after installation. • Complies with efficiency requirements of ASHRAE/IESNA 90.1-2004. • Certified to ARI Standard 390-2003 for SPVU (Single Package Vertical Units). • Commercial Product - Not intended for Residential application. Form No. S3279-206 Supersedes S3279-106 Page 1 of 12 Capacity and Efficiency Ratings 1 MODELS WL182 WL242 WL253 WL302 WL372 WL423 WL484 WL602 WL702-A WL701-B, C Cooling Capacity BTUH 1 18,300 24,000 23,000 30,000 36,000 42,000 47,500 57,500 64,000 67,000 EER 2 9.20 9.20 9.80 9.30 9.20 9.20 9.60 8.70 9.00 9.00 SEER 3 10.20 10.50 11.00 10.60 10.00 10.60 11.00 10.20 10.00 - 1 Capacity is certified in accordance with ARI Standard 390-2003 and tested in accordance with ARI Standard 210/240-2003. 2 EER = Energy Efficiency Ratio and is certified in accordance with ARI Standard 390-2003. 3 SEER = Seasonal Energy Efficiency Ratio and is tested in accordance with ARI Standard 210/240-2003. All ratings based on fresh air intake being 100% closed (no outside air introduction). SLEDOMA-281LWA-242LWB-242LWA-352LWB-352LWA-203LWB-203LWC-203LWA-273LWB-...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias