|
Instruções de Operação Friedrich, Modelo CP06
Fabricante : Friedrich Arquivo Tamanho: 2.94 mb Arquivo Nome : 386e4edd-3dc4-40ef-90b9-05a96b881f8f.pdf
|
|
|
|
Ir para baixar
Facilidade de uso
Please complete and mail the owner registration card furnished with this product or register on-line at (USA only). For your future convenience, record the model information here. MODEL NUMBER SERIAL NUMBER PURCHASE DATE 920-152-00 (01/06) ENGLISH FRANÇAIS ESPAÑOL Friedrich Congratulations! Thank you for choosing Friedrich. Your Friedrich unit is designed for maximum comfort and quietness. Table of Contents Introduction..................................................................................2 Safety Precautions.......................................................................3 How to operate your Friedrich ...................................................5 Features and Installation.............................................................7 Installation Instructions...............................................................8 Troubleshooting Tips.................................................................12 Warranty......................................................................................13 ENGLISH Introduction Before Operating Your Unit Make sure the wiring is adequate for your unit. If you have fuses, they should be of the time delay type. Before you install or relocate this unit, be sure that the amperage rating of the circuit breaker or time delay fuse does not exceed the amp rating listed in figure 1. DO NOT use an extension cord. The cord provided will carry the proper amount of electrical power to the unit; an extension cord will not. Make sure that the receptacle is compatible with the wall plug provided. This insures proper grounding. If you have a two-prong receptacle you will need to have the circuit replaced by a certified electrician with a grounded circuit that meets all national and local codes and ordinances. You must use the three-prong plug furnished with the air conditioner. MODEL CIRCUIT RATING OR TIME DELAY FUSE PLUG FACE AMP VOLT NEMA NO. CP05 CP06 15 125 5-15P © Figure 1 For the Best Cooling Performance and Energy Efficiency Keep the filter clean Make sure that your air conditioner is always in top performing condition by cleaning the filter regularly. Instructions for removing and cleaning the filter can be found on page 6. Provide good airflow Make sure that the airflow into and out of the unit is unobstructed. (both indoors and outdoors) Maximum airflow is critical for peak performance. Your air conditioner blows air out of the top of the unit and takes in air at the bottom of the unit. Unit Placement If your air conditioner can be placed in a window or a wall that is shaded by a tree or another building, the unit will operate even more efficiently. Using drapes or blinds on the sunny side of the dwelling will also add to your unit's efficiency. Insulation Good insulation will be a big help in maintaining desirable comfort levels. Doors should have weather stripping. Be sure to caulk around doors and windows. 2 Safety Precautions To prevent injury and property damage, follow these instructions. • Incorrect operation due to ignoring instructions can cause harm or damage. The seriousness is classified by the following indications. f A WARNING This symbol indicates the possibility of death or serious injury. \ <1 J CAUTION This symbol indicates the possibility of injury or damage to properties only. J • Meanings of symbols used in this manual are as shown below. 0 \ Never Do This io 0 Always Do This J Plug in the power plug properly. > Otherwise, it will cause electric shock or fire due to heat generation or electric shock. Do not modify power cord length. > It will cause electric shock or fire due to heat generation. Do not operate or stop the unit by inserting or pulling out the power plug. > It will cause electric shock or fire due to heat generation. Do not operate with wet hands or in damp environment. * It will cause electric shock. Do not damage or use an unspecified power cord. ' It will cause electric shock or fire. ' If the power cord is damaged, it must be replaced by the manufacturer or a Friedrich-certified service agent. Do not direct air flow directly at room occupants. • This could lead to health problems. * ENGLISH When the air filter is to be removed, do not touch the metal parts of the unit. * They are sharp and may cause an injury. Do not operate the unit without the air filter or when the front intake grille has been removed. 1 It could cause dust to accumulate on the heat exchanger. Do not apply an insecticide or flammable spray. 1 It may cause a fire or deformation of the cabinet. Do not clean the air conditioner with water. Water may enter the unit and degrade the insulation. It may cause an electric shock. Do not put a pet or house plant where it will be exposed to direct air flow. ■ This could injure the pets or plants. SHARP EDGES! The edges of the cabinet can be SHARP! ■ Use caution when handling the case. Grip it firm...
Escreva a sua própria avaliação do dispositivo
|
|