Log:
Assessments - 2, GPA: 3.5 ( )

Instruções de Operação Friedrich, Modelo 600312.331

Fabricante : Friedrich
Arquivo Tamanho: 173.59 kb
Arquivo Nome : f46b02bb-5a5e-4fa7-876d-cd5e517242fb.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


** * CIRCUIT PROTECTION: Time Delay 3 600312 & 600315 Series Installation Instructions 600312 & 600315 Series Installation Instructions 600312 & 600315 Series Installation Instructions A. Precautions 1/2L L L 1/3L 2/3L FIG. 2 Improper installation may damage equipment, could endanger life, cause serious injury and/ or property damage. 1. Read Installation and Operating Instructions carefully before attempting to start your air conditioner installation. 2. Dometic Corporation will not be liable for any damages or injury incurred due to failure in following these instructions. 3. Installation must comply with the National Electrical Code ANSI/NFPA-70 and CSA Standard C22.1 (latest edition and any State or Local Codes or regulations. 4. DO NOT add any devices or accessories to this air conditioner except those specifically authorized by Dometic. 5. This equipment must be serviced by qualified personnel and some states require these people to be licensed. B. Choosing Proper Location For The Air Conditioner This air conditioner is specifically designed for installation on the roof of a recreational vehicle (RV). When determining your cooling requirements, the following should be considered: • Size of RV; • Window area (increases heat gain); • Amount of insulation in walls and roof; • Geographical location where the RV will be used; • Personal comfort level required. 1. Normal Location-The air conditioner is designed to fit over an existing roof vent opening. FIG. 1 2. Other Locations-When no roof vent is available or another location is desired, the following is recommended: a. For one unit installation: The air conditioner should be mounted slightly forward of center (front to back) and centered from side to side. b. For two unit installations: Install one Air Conditioner 1/3 and one Air Conditioner 2/3’s from front of RV and centered from side to side. It is preferred that the air conditioner be installed on a relatively flat and level roof section measured with the RV parked on a level surface. Note: A 8° slant to either side, or front to back, is acceptable for all units. 3. After Location Has Been Selected: a. Check for obstructions in the area where air conditioner will be installed. See FIG. 4. b. The roof must be designed to support 130 poundswhen the RV is in motion. Normally a 200 lb. static load design will meet this requirement. CAUTION It is the responsibility of the installer of this air conditioner system to ensure structural integrity of the RV roof. Never create a low spot on the roof where water will collect. Water standing around the air conditioner may leak into the interior causing damage to the product and the RV. c. Check inside the RV for return air kit obstructions (i.e. door openings, room dividers, curtains, ceiling fixtures, etc.) See FIG. 3 & 4. FIG. 3 20" 2-1/2" 22" 9-1/2" 39" 28-3/4" 4 600312 & 600315 Series Installation Instructions FIG. 4 14-1/4" x 14-1/4” (±1/8”) OPENING 21-3/8” KEEP THESE AREAS FREE OF OBSTRUCTIONS 1...

Este manual também é adequado para os modelos :
Aparelhos de ar condicionado - 600312.331 (173.59 kb)
Aparelhos de ar condicionado - 600315.331 (173.59 kb)
Aparelhos de ar condicionado - 600315.331 (173.59 kb)
Aparelhos de ar condicionado - 600315.336 (173.59 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias