If it is, ask your dealer to instruct you on its maintenance. Your indoor evaporator coil is equipped with a drain pan to collect condensate formed as your system removes humidity from the inside air. Have your dealer show you where the main condensate drain (and auxiliary drain, if applicable) runs and how to check the drain for any obstruction. It is also very important to will be similar. Fan Switch provide unrestricted airflow to the outdoor unit. Leaves, trash or shrubs crowding the unit cause the outdoor unit to work harder and use more energy. Keep shrubbery trimmed away from the unit and periodically check for debris which may have collected around the unit. Comfort is at Your Fingertips Though your thermostat may vary somewhat from the description below, its operation Temperature Setting Levers Set the indicator lever or dial to the desired temperature setpoints for both heating and cooling. In AUTO or INT mode, the blower operates only when the thermostat calls for heating or cooling. This mode is generally preferred when humidity control is a priority. The ON or CONT mode provides continuous indoor blower operation, regardless of whether the compressor or burners are operating. This mode is required when constant air circulation or filtering is desired. System Switch Set the system switch for heating, cooling or auto operation. The auto mode allows the system to automatically switch from heating mode to cooling mode to maintain predetermined comfort settings. Temperature Indicator The temperature indicator displays the actual room temperature. Programmable Thermostats Your Lennox system may be controlled by a programmable thermostat. These thermostats provide the added feature of programmable setpoints for both heating and cooling. Refer to the user’s information manual provided with your particular thermostat for operation details. Protect Your Investment Proper Maintenance is Your Responsibility Nobody knows more about the care and operation of your new Lennox equipment than your independent Lennox dealer. This means that your independent Lennox dealer is your best choice for routine maintenance or service. Lennox’ Quality Dealer Standards program ensures that when you call your independent Lennox dealer, you can count on prompt, courteous and professional service. Before the start of each cooling season, the following air conditioning service checks should be performed by a qualified service technician. As always, electrical power to the unit must be turned off prior to any unit maintenance. . The outdoor condenser coil and indoor evaporator coil should be inspected and cleaned. The outdoor condenser coil may be flushed with a water hose. . The refrigerant lines should be visually inspected and the coils should be checked for leaks. . Wiring should be checked for loose connections. . Voltage must be checked at the indoor and outdoor units (units operating). . The amp-draw at the condenser fan motor and indoor blower motor should be checked. Values should be compared with those given on unit nameplate. . Indoor unit filters should be cleaned or replaced. . The refrigerant charge should be checked and system pressures should be gauged. . The condensate drain line should be checked for free and unobstructed flow and it should be cleaned, if necessary. ROUTINE MAINTENANCE — YOUR INDEPENDENT LENNOX DEALER CAN HELP Nobody knows more about the care and operation of your new Lennox equipment than your independent Lennox dealer. This means that your independent Lennox dealer is your best choice for routine maintenance or service. Lennox’ Quality Dealer Standards program ensures that when you call your independent Lennox dealer, you can count on prompt, courteous and professional service. Before the start of each cooling season, the following air conditioning service checks should be performed by a qualified service technician. As always, electrical power to the unit must be turned off prior to any unit maintenance. . The outdoor condenser coil and indoor evaporator coil should be inspected and cleaned. The outdoor condenser coil may be flushed with a water hose. . The refrigerant lines should be visually inspected and the coils should be checked for leaks. . Wiring should be checked for loose connections. . Voltage must be checked at the indoor and outdoor units (units operating). . The amp-draw at the condenser fan motor and indoor blower motor should be checked. Values should be compared with those given on unit nameplate. . Indoor unit filters should be cleaned or replaced. . The refrigerant charge should be checked and system pressures should be gauged. . The condensate drain line should be checked for free and unobstructed flow and it should be cleaned, if necessary. ROUTINE MAINTENANCE — YOUR INDEPENDENT LENNOX DEALER CAN HELP Be Prepared with the Information Your Dealer Will Need If your system fails to operate, check the following before calling for service: . Check to see that all electrical d...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias