Instruções de Operação APC, Modelo AP7003

Fabricante : APC
Arquivo Tamanho: 613.23 kb
Arquivo Nome : NetworkAir_1000.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


• This air conditioner is designed for indoor use only. The temperature range for the cooling mode is 61° F to 86° F. • To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. Do not open the cabinet while the unit is connected a power source. Dangerous voltage is present. Have repairs performed by certified HVAC technicians. • Never use or store gasoline or other flammable vapor or liquid near the unit. • This air conditioner has no ventilator for taking in fresh air from outdoors. You must open doors or windows frequently when you use gas or oil heating appliances in the same room, which consume a lot of oxygen from the air. Otherwise, there is a risk of suffocation in extreme cases. • Do not use an adapter plug or extension cord. • Do not use near gas appliances, open flames (fireplaces) or in the vicinity of flammable liquids. Caution • Do not operate this unit if it has a damaged cord or plug, or if it is not working properly, or had been dropped or damaged in any manner. • To protect against risk of electrical shock, do not immerse unit, cord or plug in water or any other liquid. • Do not cut or remove the third (ground) prong from the power cord plug. • If the plug gets hot, call a qualified electrician. • Close supervision is required when the unit is used near children. • Do not stick anything into the air outlet of the air conditioner. • Do not use in a room with poor air circulation. • Do not expose to direct sunlight. • Do not use the unit near water. Contents General Information . . . . . . . . . . . . . . . . . . . . . . . .1 About NetworkAIR 1000 1 Inventory 1 Front View 2 Back View 2 Control Panel 3 LCD Indicators 4 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Warnings 5 Set up the unit 5 Check components 6 Power the unit 6 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Power 7 Cooling 7 Dehumidify 7 Fan 7 Louver 7 Timer 8 Installing the ExhaustKit . . . . . . . . . . . . . . . . . . . .9 Drainage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Methods of Draining 11 Condensate Tank 11 Emptying the tank 12 The drainage tube 13 Maintaining the Unit . . . . . . . . . . . . . . . . . . . . . .14 Clean the air filter 14 Clean the cabinet 14 Clean the condensate tank regularly 15 Storing the Unit 16 Contents continued Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . .17 Try this first 17 If problems persist 19 Warranty Information . . . . . . . . . . . . . . . . . . . . .20 Limited warranty 20 Warranty limitations 20 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 1 General Information About NetworkAIR 1000 APC’s NetworkAIR 1000 is a portable, compact, airconditioner designed for spot-cooling, emergency-cooling, and after-hours cooling of server closets, data centers, conference rooms, home offices, or rooms housing heat-sensitive equipment. The NetworkAIR 1000 provides 7,200 BTU (7,500 BTU for AP7004) of cooling power. It automatically adjusts room temperature, and reduces moisture while filtering the air. Additional features of NetworkAIR 1000 include: • Electronic control panel with LCD display • Automatic turn-on/shut-off timer • Automatic swing louvers for even air distribution in the room • Ceiling exhaust kit • Quiet, high-efficiency rotary compressor Inventory NetworkAIR 1000 is shipped with the items shown below: NetworkAIR 1000 Air Conditioning Unit Ceiling Adapter Exhaust Duct Holder Flange Base Flange Drain Tube 2 General Information continued Front View Back View Control Panel Horizontal Air Flow Guides Vertical Swing Louver Handle Water Tank Caster Power Cord & Plug Washable Air Filter Exhaust Vent Drain Valve General Information continued Control Panel Power Turns the unit on and off. Mode Sets the desired operating mode: fan, cooling, or dehumidifying. Fan Speed Sets desired fan speed: high, medium or low. Louver Directs the air distribution. Temperature Sets the desired temperature (61°– 86°F). Timer Programs the timer for unattended shutoff (up to 18 hours for AP7003, 24 hours for AP7004). Compressor indicator Indicates that the compressor is running when in cooling or dehumidifying mode. Tank Full indicator Indicates with flashing light and buzzer that the condensate tank is full or has not been positioned correctly. LCD Display Displays information about different modes and settings. General Information continued LCD Indicators . Temperature . Fan Mode . Cooling Mode . Dehumidify Mode . Louver On . Timer On/Off . Timer Setting . Fan Speed . Set Temperature Note: Temperature is shown in Celsius on the AP7004. 5 Installation Warnings Use the unit on a flat surface where the air outlets are unobstructed. Do not place the unit less that 20 inches (50 cm) away from any wall or obstacle. Do not install this air conditioner where there are fumes or flammable gases, or in an extremely humid space such as a green house. Set up the unit 1. Un...

Este manual também é adequado para os modelos :
Aparelhos de ar condicionado - AP7004 (613.23 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias