|
Facilidade de uso
GB When the water container is full, the compressor and the ventilator stop functioning, the POWER LED will flash. Switch off the unit and remove the plug from the mains. • Place the water tray flat on the floor under the drain. • Remove the drain knob. • Remove the rubber plug and fill the water tray then replace the plug to stop the water flow. Empty the tray and repeat this process until all water has been removed. • Replace the rubber plug and the drain knob, plug the unit in and switch on. The POWER LED should not flash any longer. EMPTYING THE INTERNAL WATER CONTAINER a b Rubber plug Water tray Drain knob 8 GB Switch off the unit and remove the plug from the mains. • Remove the drain knob and the rubber plug. • Connect the correct water tube onto the water outlet. • Place the other end in a normal drain. • Make sure that the tube is free from twists and bends. The tube must incline over its entire length. Dehumidification If the unit will be used mainly as dehumidification, do not connect the exhaust hose and let the warm air return in the room. Continuous drainage is then convenient and more efficient. First of all switch off the unit and pull the plug. Clean the housing with a soft, damp cloth. Never use aggressive chemicals, petrol, detergents or other cleansing solutions. Filter The single layer screen filter cleans the circulated air. The filter needs to be cleaned regularly with a vacuum cleaner to avoid blocking the air flow. Notice! Never use the air conditioner without filter. CLEANING PERMANENT DRAINAGE 9 GB STORAGE See the instructions "Emptying the water container" on page 7. • Drain the condensed water completely. • Clean (or replace) the filter. • Put the unit on a sunny day in fan mode for a couple of hours to ensure that the inside becomes completely dry. • Store the power cable as shown, protect the unit against dust and store in a dry place not accessible for children. Cable storage Never try to repair or dismantle the air condition yourself. Incompetent repairs result in loss of warranty and can endanger the user and the property. Problem Cause Solution The air conditioner does not function. No power supply. Connect to a functioning outlet and switch on. Is the LCD light fl ashing. Empty the internal water container. Timer function is active. Deactivate TIMER function. The air conditioner does not seem to perform. In direct sunlight. Close curtains. Windows or doors open, many people or a heat source in the room. Close doors and windows, place an extra air conditioner. Dirty filter. Clean or replace the fi lter(s). Air inlet or air outlet blocked. Remove the blockage. Room temperature lower than the selected value. Change temperature selection. The unit is noisy. Unit stands uneven. Place on an even, solid surface (less vibrations). The compressor does not work. The overheat protection is probably activated. Wait 3 minutes until the temperature has decreased, then turn on the unit again. The remote control does not function. Distance too great. Make sure the remote control is correctly Remote control signal not detected aimed at the control panel. by the control panel. The batteries are drained. Replace the batteries. To correct problems that have not been described in the table and/or if the recommended solutions fail to solve the problem, contact an authorized service centre. TROUBLE SHOOTING 10 GB Model AMC 7KE-410 AMC 10KE-410 AMC 12KE-410 Cooling capacity BTU/h 6500 8300 9600 kW 1.9 2.4 2.8 Mains 220–240 V / 50 Hz / 1Ph Power consumption W 690 830 1030 Current A 3 3.7 4.5 Dehumidification L/24h 24 28.8 36 Air delivery m3/h 300 350 350 Recommended room size m2 12 18 24 Refrigerant R410A Compressor rotary Fan speeds 2 Thermostat °C 18 – 32 Timer h 1 – 12 Dimensions (W x H x D) mm 377 x 750 x 400 Weight kg 29 30 32 Subject to modifications without prior notice. Please refer to the rating label for greater precision. TECHNICAL DATA Reminder: Waste electrical products must not be disposed of with household waste. This product should be taken to your local recycling centre for safe treatment. 0 5 2 4 2 13 1 9 C M A Hong Kong China Shan Xia Industrial Development Zone, Heng Li Town, Dongguan City, Guangdong Province, China Plant One - Amcor (China) Ltd Tel: +86 769 8372 1090 Fax: +86 769 8372 1790 Email: amcorcn@amcorgroup.com Plant Two - Amcor Appliances Ltd Tel: +86 769 8372 1970 Fax: +86 769 8372 1790 Email: amcorappl@amcorgroup.com Amcor Ltd Suite 2007, Tower 6, The Gateway, Harbour City, 9 Canton Road, Tsim Sha Tsui, Kowloon, Hong Kong Tel: +852 2997 6865 Fax: +852 2997 6091 Email: amcorhk@amcorgroup.com United Kingdom Amcor Ltd 9 Ryan Drive, West Cross Centre, Great West Road, Brentford, Middlesex, TW8 9ER, United Kingdom Tel: +44 20 8560 4141 Fax: +44 20 8232 8814 Email: amcoruk@amcorgroup.com USA Amcor Inc. 685A Gotham Parkway, Carlstadt, New Yersey 07072, United States of America Tel: +1 201 460 8100 Fax: +1 201 460 9481 Email: amcorusa@amcorgroup.com The Netherlands Amcor B....
Este manual também é adequado para os modelos :Aparelhos de ar condicionado - 7KE-410 (1.09 mb)
Aparelhos de ar condicionado - 12KE-410 (1.09 mb)