Facilidade de uso


You can select the On timer only when the air conditioner is off. You can select the On timer when the air conditioner operates in the Cool or Dry mode. 1 Check that the air conditioner has been switched off; if necessary, press the (!) (On/Off) button. Set the operating time by pressing the fffl) button on the remote control or I a I button on the unit one or more times until the desired time is displayed. The operating time can be set between 1 and 24 hours. Result: ♦ Each time you press the I ¡3) I button: - The time is adjusted by 1 hour and displayed on the control panel - The unit beeps ♦ The operating time is displayed and decreases automatically to indicate the remaining time. ♦ The air conditioner starts up in the Cool or Dry mode automatically when the operating time reaches zero. You can select the fan speed, temperature and Energy saving mode after setting the On timer and Off timer mode. However, when you change the mode, the On timer and Off timer mode is canceled. To Cancel the On Timer To cancel the timer, press: ♦ Timer on the remote control or unit one or more times untilis displayed, or The (!) (On/Off) button on the remote control or unit (The air conditioner operates in the mode selected when the unit was last used.) e-12 Setting the Off Timer The Off Timer enables you to switch off the air conditioner automatically after a given time. You can select the Off timer only when the air conditioner is on. You can select the Off timer when the air conditioner operates in the Cool or Dry mode. 1 Check that the air conditioner has been switched on; if necessary, press the (!) (On/Off) button. Remote Control Control Panel Set the operating time by pressing the (0) button on the remote control or i p i button on the unit one or more times until the desired time is displayed. The operating time can be set between 1 and 24 hours. Result: ♦ Each time you press the i a i button: - The time is adjusted by 1 hour and displayed on the control panel - The unit beeps ♦ The operating time is displayed and decreases automatically to indicate the remaining time. ♦ The air conditioner switches off automatically when the operating time reaches zero. You can select the fan speed, temperature and Energy saving mode after setting the On timer and Off timer mode. However, when you change the mode, the On timer and Off timer mode is canceled. Mode *l»l* 0» ■£> To Cancel the Off Timer To cancel the timer, press: Timer on the remote control or unit one or more times untilis displayed, or The (!) (On/Off) button on the remote control or unit. O'13) ENGLISH Setting the Sleep Timer The Sleep Timer can be used when you are cooling your room to switch the air conditioner off automatically after 8 hours. 5s» If you wish to switch the unit off at a specific time, refer to page 13. Remote Control Control Panel (S) ©I * 1 Make sure that you have selected the Cool mode. Œ) Ç3D Press the I •‘¡B 1 button on the remote control or Press the I ■•£> I button on the unit. Result: ♦ Each time you press a button, the unit beeps. ♦ The " B " will be displayed. ♦ The remaining time is displayed and decreased by 1 hour automatically to indicate the remaining time. ♦ The air conditioner will be controlled as illustration below. Cooling When the temperature has been increased by 1°C (after 1 hour), it is maintained for 7 hours. To Cancel the Sleep Timer CJD O'14) To cancel the timer, press: ♦ Sleep on the remote control, or ♦ Sleep on the unit. Result: ♦ The unit beeps. ♦ The SLEEP indicator is no longer displayed. ♦ The air conditioner operates in the mode selected last. If you select the Energy Saving mode in the Sleep Timer mode, the Sleep Timer will be cancelled and the air conditioner will start up in the Energy Saving mode. Selecting Energy Saving Mode If you wish to save energy when using your air conditioner, select the energy saving mode. 1 To select the energy saving mode, press the GO button on the remote control or I q» I button on the unit one or more times until the Energy Saver indicator lights up. Result: ♦ The fan and compressor cycle on and off together. ♦ The fan will continue to run for a short time after the compressor cycles off. 5^ If you would like the air conditioner to run in Dry mode, do not press the I q8 I button. You cannot use the Dry mode in the energy saving mode. Remote Control Control Panel 2 To stop the energy saving mode, press the QO button on the remote control orl 0» I button on the unit again. Result: The fan runs at all times, while the compressor cycles on and off. 5^ If you select the Sleep Timer in the Energy Saving mode, the Energy Saving will be cancelled and the air conditioner will start up in the Sleep Timer mode. (e'15I ENGLISH Temperature and Humidity Ranges The following table indicates the temperature and humidity ranges within which the air conditioner can be used. Mode Indoor Temperature Outdoor ...

Este manual também é adequado para os modelos :
Aparelhos de ar condicionado - dac10507ee (1.27 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias