|
Facilidade de uso
If in a climate with cold winters, once a year is adequate. 5. Insert cleaned or new black filters back into the unit. 4. Insert cleaned or new small filters (Deodorizing and Electrostatic) back into the unit. INSTALLING THE REMOTE BRACKET To install the remote bracket, insert one of the 2 supplied screws into top hole of the bracket and into the wall. Level the remote bracket and insert the other screw into the bottom hole. Insert the remote controller when not using it. 13 CLEANING THE INDOOR COVER To clean the indoor cover, follow the procedures below 1. Remove the left and right side to open the indoor cover upward by two hand NOTE: Please remove and insert the indoor by two hand 2. Open the door until 80 degree 80° 3. Pull right side to remove indoor cover hinge from frame grille hinge hole 4. Remove the indoor cover 5. Cleaning the indoor NOTES: • Wipe the indoor cover with soft sponge or soft cloth. • When cleaning up it in the state of opening the indoor cover, wipe it with soft cloth • After drying it completely in the shade, assemble it. • If you do not so, it may cause a trouble 14 CARE AND MAINTENANCE warning • Make sure the AC cord is unplugged and the unit is off before cleaning. • Do not use water on the unit to clean it. This is a shock hazard and the unit can be damaged. Clean the casing and front of the indoor unit with a vacuum brush or wipe with a clean damp cloth. • NEVER USE Solvents, harsh chemicals or hot water to clean the unit. • Some metal edges on the unit are sharp. Be careful when cleaning or handling. • Internal parts in the outdoor unit may need cleaning or routine maintenance from time to time. Consult your local service center for more details. AFTER THE SEASON: • Operate the fan, then dry the indoor unit. • Shut off the indoor unit and then unplug it from the wall. • Clean the air filters. • Cover the outdoor unit with the supplied cover; this is very important to protect this unit. BEFORE THE SEASON: • Make sure the air filters are clean. • Make sure the inlet and outlet on the indoor and outdoor units are not blocked by obstructions. • Make sure the unit is grounded. Consult a serviceman for help. PRECAUTIONS: • Do not use this unit for animal or plant storage. • In a lightning or thunder storm, immediately unplug it from the wall. 15 TROUBLESHOOTING GUIDE Before requesting service, please refer to the chart below for possible solutions: SYSPTOMS POSSIBLE CAUSE POSSIBLE SOLUTIONS No power. Power failure. Restore the power Line voltage too low. Contact electrician to install new outlet. Unit is unplugged or not completely Insert plug all the way. plugged in. Unit is off. Turn unit on. Batteries in remote are weak or dead. Replace remote’s batteries. EMERGENCY/REMOTE Slide EMERGENCY/REMOTE switch is not set to REMOTE. to REMOTE. The compressor does When the unit is first plugged in Wait 3 minutes for the unit to operate. not turn on. and turned on, the compressor (no cool air at cooling) will delay turn on for 3 minutes. (no heat air at heating) If the unit is turned off and then Wait 3 minutes for the unit to operate. immediately back on, the compressor will delay for 3 minutes. The air filter(s) is dirty or clogged. Clean or replace filter(s). A door or window is open. Shut door or window. There is an obstacle in front of Remove obstacle. intake or indoor unit. The temperature has been set Check and reset if necessary. improperly. Strange sounds occur. During operation, especially after This is normal. turning it on or off, refrigerant flows inside the unit. Strange smells occur. The fan is bringing out the The smell should go away shortly. smells of the carpet, walls, etc. No remote operation. Batteries are weak, dead or Replace batteries. inserted improperly. Remote is out of range. Move closer to unit. Remote not aimed at sensor. Aim remote at sensor. There is an obstruction between Remove obstruction. unit and remote. 16 INSTRUCTION OF INSTALLATION Below is an overview for the connection of the Indoor unit to the Outdoor unit. OVERVIEW This appliance must be installed according to national power supply acquirement. Drain Hose Ground Wire (Not Supplied) 5/8" side piping Oxygen tubeConnecting cable 3/8" side piping Drain Hose Pipes (Not Supplied) Wall Bracket AC Connection (Not Supplied) Wrap with Tape AC Outlet and Plug Copper Tubing 10cm (3.95in) from ceiling At least 30cm (11.8in) from unit 30cm (11.8in) from side wall 10cm (3.95in) from side wall Maximum Height 7M (21Ft) Maximum Length 15M (49Ft) Any tube length between 7 and 15 meters must be precharged with freon using the following calulation: (Length – 5) x 30 grams Adding additonal tubing will decrease efficiency10cm 70cm 60cm 3.9 inches 23.6 inches 60cm23.6 inches 27.6 inches Plug into 220V~240V AC Outlet 5/8" side piping Connecting cable 3/8" side piping Drain Hose NOTES: • After installation it must be possible for the user to dis - connect the power supply plug. • If the AC outlet is a 3pronged type or oth...
Este manual também é adequado para os modelos :Aparelhos de ar condicionado - DSB-F183L (229.03 kb)
Aparelhos de ar condicionado - DSB-F183L (229.03 kb)
Aparelhos de ar condicionado - DSB-F183L (229.03 kb)
Aparelhos de ar condicionado - DSB-F183L (229.03 kb)