|
Facilidade de uso
[] Be sure your air conditioner does not fall out of the opening during installation or removal. [] The place where the power cord exits the air conditioner should be no more than 4 ft (122 cm) from a grounded outlet. [] Do not block the louvers in the front panel. [] Do not block the louvers on the outside of the air conditioner. Sash Sas Window sill 7 Curtain lock Flange A. Side curtain against window channel B. Window sash behind top channel C. Bottom channel in behind windowsill 5, Install left & right installation bracket and as shown in fig. Install outer case in window 1, Place outer case in window. Lower sash until it rests behind front flange of top channel. Bottom channel must rest behind window sill. AB A_ouf 5° 0 __. C A. Top channel B. Window sash C. Bottom channel 2. Expand both curtains to contact the window frame. Install four wood screws. One in each upper right and left of the curtains and one in each bottom tab. 3. Install one screw through center hole on top channel. 4. Use two wood screws 31/32" to fix the case to windows sash. Install bolt(2 1/2" long flat head bolt and locknut) to the instal lation bracket and adjust them to proper length ,then use 4 short screws to fix the bracket on the case. 6. Use a wood block between the leveling bolts and the wall if the wall is weak or if the weight of the air conditioner falls between the studs in the wall. 1. Insert the foam seat behind the top of the lower window sash and against the glass of the upper window. A NOTE: To make screws easier to drive, drill a pilot hole into the A. Top of lower window sash sash through clearance hole in curtains. B. Foam seal 2, Place the window lock bracket as shown. Use a 1/s"drill bit to drill a starter hole through the hole in the window lock bracket and into the upper window. 3, Attach the window lock bracket to the upper window with one 3142"screw to secure the window in place. 4. Plug into a grounded 3 prong outlet. 5. Press RESET on the power supply cord. See "Electrical Requirements." Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock. 1. Plug into a grounded 3 prong outlet. 2. Press RESET on the power supply cord. See "Electrical Requirements." IF AC IS BLOCKED BY STORM WINDOW Return chassis to the outer case • Add wood as shown in FIG.6,or remove storm window before air conditioner is installed. Find someone to help you replace the chassis in outer case. • If storm window frame must remain,be sure the drain Replace front panel and grille. holes or slots are not caulked or painted shut. Accumulated rain water or condensation must be allowed to drain out. Sash Board thickness 1-1/2"MIN as required,for Storm window (38mm) frame or other proper pitch to obstruction | _- _{ rear,along entire sill,fasten with nails or screws. i -yj ij .,, iMPORTANT: Because the window sash helps keep the unit in window, make certain the window sash contacts the outer case before reinstalling the chassis. AIRCONDITIONERUSE Operating your air conditioner properly helps you to obtain the best possible results. This section explains proper air conditioner operation. iMPORTANT: -If you turn off the air conditioner, wait at least 3 minutes before turning it back on. This keeps the air conditioner from blowing a fuse or tripping a circuit breaker. Do not try to operate your air conditioner in the Cool mode when outside temperature is below 61°F (16°C). The inside evaporator coil will freeze up, and the air conditioner will not operate properly. NOTE: In the event of a power failure, your air conditioner will operate at the previous settings when the power is restored. Energy SaveriFan runs only when cooling is needed. Press SPEED to select High, Med or Low fan speed. Because the fan does not circulate the room air continuously, less energy is used, but the room air is not circulated as often. Dehum--Dries the room. The air conditioner automatically selects the temperature. Fan runs on Low speed only. NOTE: Dry mode should not be used to cool the room. D_Y 0 ENER6YSAVER 0 CA. 1. Remove the clear plastic film from the control panel. 2. Press POWER to turn on the air conditioner. The Power indicator light will turn on. NOTE: After 5 seconds, display will show the current room temperature. Fan Speed 3. Select mode. See "Mode." NOTE: In Dry mode, the Speed button will not operate. 4. Select fan speed. See "Fan Speed." 1. Press SPEED until you see the indicator light glow for 5. Set temperature. See "Temperature." the desired setting. 2. Choose High, Med or Low. High--for maximum cooling Mode Med--for normal cooling Low--for minimum cooling 1. Press MODE until you see the indicator light glow for the desired setting. 0 HIGH 2. Choose Fan, Cool, Energy Saver or Dry. _J_ ME. Fan--Only the fan runs. Press SPEED to select High, Med LOW or Low fan speed. The display s...
Este manual também é adequado para os modelos :Aparelhos de ar condicionado - BWE18A (1.69 mb)
Aparelhos de ar condicionado - BWE25A (1.69 mb)