Facilidade de uso
Push right side of connector flange into right side of vent opening. Adjust connector flange slightly so it is square in the opening. The foam gaskets will rest between the connector and the edge of the vent opening. 5. Push nozzle onto small connector end of vent duct pipe. 6. Place nozzle out an open window or through an exterior wall. Contact an experienced contractor or qualified craftsman to modify wall or windows, if necessary. To use the Exhaust Duct Kit with other Freecom accessories, follow installation instruc tions supplied with the accessory. OPERATION (contd.) Dehumidifying WARNING: DO NOT use Exhaust Duct Kit when operating as a dehumidifier. 1. Plug power cord into a standard household outlet. Use this product only with the proper electrical voltage. WARNING: Do not plug this appliance into an outlet that is being used by other appliances or electrical devices. When installing the electrical plug into the outlet, never touch or bend the metal prongs and always push plug into outlet by using the molded plug. Never use the electrical plug to start or stop the unit and avoid pulling, folding, or stretching the electrical cord. 2. Press “POWER ON/OFF” button on control panel. The unit will power up and air will begin blowing from the front louvers. 3. Press “AIR VOLUME” button on control panel to choose “DEHUMID.” 4. If desired, press “TIMER” button on control panel to program the dehumidifier to turn off in either 1, 2, or 3 hours. 5. To turn unit off manually, press “POWER ON/OFF” button. Unplug power cord from outlet when not in use. THE CONTROL PANEL 4 5 1 23 1. POWER ON/OFF Easy push-button control switch to turn the unit ON and OFF 2. AIR VOLUME There are five different air volume selections: •HI • HI RHYTHM •LO • LO RHYTHM • DEHUMID. 3. TIMER Adjustable 3 hour timer can be programmed to turn off air conditioner after 1, 2, or 3 hours 4. AUTO LOUVER Choose between fixed position or oscillating (70 degrees) vertical louvers 5. FULL TANK INDICATOR The full tank indicator will automatically light and a “beep” will sound when the condensate water tank is full, removed, or not properly installed. SPECIFICATIONS Model Power/Electrical Cooling Capacity Input EER Requirements RCS-M1000T 110/115 volt, 60Hz 4000 BTU/h (1170W) 410W 9.76 RCS-M1000U 220/240 volt, 50Hz 3500 BTU/h (1030W) 310W N/A BEFORE USING IMPORTANT: Remove unit from packaging and discard clear, plastic wrapping. Place unit in its upright position for a minimum of two hours before operating for the first time. 1. 2. 3. 4. Place unit on a solid, level surface. Operating this unit on uneven or soft surfaces may cause vibration, noise, and possible water leakage from the condensate tank. Place unit at least 20" from any walls, draperies, or other obstructions. Carefully push the unit on its caster wheels to desired location. CAUTION: Do not operate unit without condensate water tank and air filters properly in place. Check that condensate water tank is properly installed. When properly installed, the door of the condensate water tank will be flush with the exterior of the unit. Check that both air filters are clean and properly installed. OPERATION CAUTION: To avoid damage and voiding your warranty, place unit in its upright position for a minimum of two hours before operating. DO NOT operate unit without condensate water tank and air filters properly in place. Cooling This unit is intended to cool a 100-120 s.f. area. The unit’s cooling capacity will vary according to room temperature and humidity. Consult your Freecom dealer for specific application and suitability. 1. Plug power cord into a standard household outlet. Use this product only with the proper electrical voltage. See “SPECIFICATIONS” on previous page. WARNING: Do not plug this appliance into an outlet that is being used by other appliances or electrical devices. When installing the electrical plug into the outlet, never touch or bend the metal prongs and always push plug into outlet by using the molded plug. Never use the electrical plug to start or stop the unit and avoid pulling, folding, or stretching the electrical cord. 2. Press “POWER ON/OFF” button on control panel. The unit will power up and air will begin blowing from the front louvers. NOTE: This unit is equipped with a special safety time delay feature. The compressor (cooling mechanism) may be delayed for up to five minutes. This safety feature prevents damage to the compressor. 3. Press “AIR VOLUME” button on control panel to choose between “LO” or “HI.” You may also choose “RHYTHM LO” or “RHYTHM HI” to allow for a more “gentle breeze” of cooled air. 4. If desired, press “TIMER” button on control panel to program the air conditioning unit to turn off in either 1, 2, or 3 hours. CAUTION: To avoid damage and voiding the warranty, DO NOT manually adjust the vertical louvers. 5. Adjust horizontal louvers (up or down) as desired by moving the louver handle located at the top, left corner of the horizontal air louver...
Este manual também é adequado para os modelos :Aparelhos de ar condicionado - PORTABLE AIR CONDITIONER RCS-M1000T (91.54 kb)