Instruções de Operação Goodman Mfg, Modelo ATUF

Fabricante : Goodman Mfg
Arquivo Tamanho: 326.16 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


940 890 860 815 755 Low 695 665 650 610 550 ADPF30421/16 High 1,700 1,660 1,625 1,545 1,505 Med. 1,500 1,440 1,400 1,350 1,345 Low 1,370 1,300 1,250 1,230 1,220 ADPF48601/16 High 2,150 2,120 2,070 2,000 1,940 Med. 1,940 1,930 1,905 1,860 1,790 Low 1,610 1,600 1,590 1,575 1,550 NOTE: Assumes dry coil with filter in place; SCFM correction for wet coil = 4% (208V/240V) Model Speed CFM deliverd against External Static Pressure 0.1" 0.2" 0.3" 0.4" 0.5" ATUF182416 High 1155 1090 1025 950 895 Med. 875 830 790 750 715 Low 640 610 570 535 490 ATUF193116 High 1135 1085 1025 965 915 Med. 860 825 780 750 680 Low 600 570 545 500 465 ATUF303016 High 1455 1385 1330 1205 1090 Med. 1340 1290 1230 1140 1050 Low 1075 1030 980 910 840 ATUF363616 High 1345 1290 1230 1150 1070 Med. 1270 1210 1140 1075 980 Low 1045 1005 955 885 805 ATUF364216 High 1700 1680 1645 1610 1535 Med. 1500 1480 1440 1380 1325 Low 135 1320 1275 1230 1195 ARUF374316 High 2065 2000 1925 1860 1780 Med. 1685 1635 1550 1470 1410 Low 1490 1425 1345 1280 1205 ATUF486016 High 2135 2080 1985 1900 1805 Med. 1975 1935 1875 1775 1675 Low 1715 1670 1650 1590 1530 NOTE: Assumes dry coil with filter in place; SCFM correction for wet coil = 4% (208V/240V) ASPF Motor The ASPF air handler features an energy efficient blower motor. The motor is a constant torque motor with very low power consumption. The motor is energized by 24 VAC. Adjust the CFM by changing the 24 VAC leads to the desired speed on the terminal block. The ASPF motor blower speed is programmed to deliver adequate airflow at rated external static pressure and with 60 second off time delay. For details, refer to the specification sheet applicable to your model. CFM Delivery Table 13 shows the CFM speed tap settings for the ASPF. Thermostats NOTE: Second Stage heat can be accomplished by multistage heating thermostat or the addition of an outdoor 10 thermostat as shown in Figures 10 and 11. Goodman® part number CHT18-60 is a single-stage cool and single-stage heat thermostat. Goodman® part number HPT18-60 is a single-stage cool, two-stage heat pump thermostat. The first stage is heat pump heating and the second stage is optional electric heat. If additional features are desired, such as digital or programmable capabilities, these thermostats are commercially available. Follow the thermostat manufacturer’s instruction for installation. Start-Up Procedure • Prior to start-up, ensure that all electrical connections are properly sized and tightened. • All panels must be in place and secured. For Air Tight application, neoprene gasket must be positioned at prescribed locations to achieve 2% leakage. • Tubing must be leak free. • Unit should be elevated, trapped and pitched to allow for drainage. • Low voltage wiring is connected. • Auxiliary drain is installed when necessary and pitched to allow for drainage. • Drain pan and drain tubing has been leak checked. • Return and supply ducts are sealed. • Unit is elevated when installed in a garage or where flammable vapors may be present. • Unit is protected from vehicular or other physical damage. • Return air is not obtained from any areas where there may be objectionable odors, flammable vapors or products of combustion such as carbon monoxide (CO), which may cause serious personal injury or death. Regular Maintenance HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause propertydamage, personal injury or death. The only item to be maintained on a regular basis by the user is the circulating air filter(s). Filter should be cleaned or replaced regularly. A certified service technician must perform all other services. NOTE: DO NOT USE THESE DIAGRAMS FOR AEPF MODELS. SEE INSTALLATION AND OPERATING INSTRUCTIONS SPECIFICALLY FOR AEPF MODELS. Model Motor Speed Tap CFM deliverd against External Static Pressure 0.1" 0.2" 0.3" 0.4" 0.5" ASPF183016 1 700 670 650 595 510 2 820 785 765 (Highlight) 745 705 3 920 900 850 840 815 4 1075 1055 1015 975 960 5 1130 1115 1085 1040 1000 ASPF303616 1 1060 865 600 515 420 2 1105 910 795 745 690 3 1165 1070 1020 960 915 4 1285 1240 1195 1140 1100 5 1435 1395 1350 1315 1265 ASPF313716 1 1060 865 600 515 420 2 1105 910 795 745 690 3 1165 1070 1020 960 915 4 1285 1240 1195 1140 1100 5 1435 1395 1350 1315 1265 ASPF426016 1 1445 1275 1175 940 855 2 1545 1405 1325 1260 1145 3 1660 1610 1555 1490 1415 4 1905 1870 1810 1750 1695 5 2115 2070 2000 1965 1915 Table 13 11 HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. WARNING HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. WARNING ROOM THERMOSTAT #18 GA. 4 WIRES WITH COOLING 3 WIRES WITHOUT AT/AR UNIT R G W Y #18 GA. 2 WIRES W Y G R TO CONDENSING CONTACTOR UNIT 24V. CONNECTIONS BLUE WHITE G...

Este manual também é adequado para os modelos :
Aparelhos de ar condicionado - ADPF (326.16 kb)
Aparelhos de ar condicionado - ARUF (326.16 kb)
Aparelhos de ar condicionado - ASPF (326.16 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias