|
Facilidade de uso
Rating conditions: Cooling - Indoor 27.CDB, 19.CWB; Outdoor 35.CDB Heating - Indoor 20.CDB ; Outdoor 7.CDB,6.CWB . Data based on indicated voltage Indoor unit : 1-ph, 240V, 50Hz Outdoor unit : 1-ph, 240V, 50Hz/3-ph, 415V, 50Hz . Refrigerant piping length (one-way): 5m (16ft) . Refrigerant charge is suitable for 5m piping length. ¦ Guaranteed Operating Range Limits Indoors Outdoors Cooling Lower 21.C DB, 15.5.C WB -5.C DB Upper 35.C DB, 22.5.C WB 46.C DB Heating Lower 20.C DB -8.5.C DB, -9.5.C WB Upper 27.C DB 21.C DB, 15.5.C WB ¦ Refrigerant Piping Models Between indoor & outdoor units Pipe size O.D., mm Max. height difference, m Max. piping length, m Max. number of bends Liquid Gas PLH-3AAK, PKH-3FAK, PCH-3GAK, PEH-2.5EAK, PEH-3EAK 50 50 15 O 9.52 O 15.88 PKH-4FAK PLH-4/5/6AAK, PCH-4/5/6GAK, PEH-4/5/6EAK 50 50 15 O 9.52 O 19.05 ¦ Optional Refrigerant Pipes Pipe length Part number 5m (16ft) PAC-05FFS-E PAC-SC51PI-E 7m (23ft) PAC-07FFS-E PAC-SC52PI-E 10m (33ft) PAC-10FFS-E PAC-SC53PI-E 15m (49ft) PAC-15FFS-E PAC-SC54PI-E Connection method Flared-flared Flared-flared Pipe size OD, mm (ft) Liquid: O 9.52 (3/8) Gas: O 15.88 (5/8) Liquid: O 9.52 (3/8) Gas: O 19.05 (3/4) Applicable models PKH-3FAK, PLH-3AAK, PCH-3GAK, PEH-2.5EAK, PEH-3EAK PKH-4FAK, PLH-4/5/6AAK, PCH-4/5/6GAK, PEH-4/5/6EAK ¦ Additional Refrigerant Charge [R-22: kg] Models Piping length (one-way) 5m 10m 15m 20m 25m 30m 35m 40m 45m 50m PUH-2.5AKA 0 0 0 0 0 0 0.2 0.2 0.5 0.5 PUH-3VKA/PUH-3YKA 0 0 0 0 0 0 0.2 0.2 0.5 0.5 PUH-4YKSA 0 0 0 0 0 0 0.3 0.3 0.6 0.6 PUH-5YKSA 0 0 0 0 0 0 0.3 0.3 0.6 0.6 PUH-6YKSA 0 0 0 0 0 0 0.3 0.3 0.6 0.6 ¦ Cooling Capacity Correction Factors Models Correction factors (Cooling / Heating) One-way piping length, m 5 10 15 20 25 30 35 40 45 50 PEH-2.5EAK 1.00/1.00 0.989/1.00 0.980/1.00 0.970/1.00 0.960/1.00 0.950/1.00.0.9 40 /0 99 8.0.9 30 /0 99 5.0.9 20 /0 99 3.0.9 10 /0 99 0 PKH-3FAK, PCH-3GAK, PLH-3AAK, PEH-3EAK 1.00/1.00 0.981/1.00 0.968/1.00 0.952/1.00 0.940/1.00 0.925/1.00.0.9 13 /0 99 8.0.9 00 /0 99 5.0.8 86 /0 99 3.0.8 74 /0 99 0 PKH-4FAK PCH-4GAK, PLH-4AAK, PEH-4EAK 1.00/1.00 0.989/1.00 0.980/1.00 0.970/1.00 0.960/1.00 0.950/1.00.0.9 40 /0 99 8.0.9 30 /0 99 5.0.9 20 /0 99 3.0.9 10 /0 99 0 PCH-5GAK PLH-5AAK, PEH-5EAK 1.00/1.00 0.981/1.00 0.968/1.00 0.952/1.00 0.940/1.00 0.925/1.00.0.9 13 /0 99 8.0.9 00 /0 99 5.0.8 86 /0 99 3.0.8 74 /0 99 0 PCH-6GAK, PLH-6AAK PEH-6EAK 1.00/1.00 0.975/1.00 0.955/1.00 0.935/1.00 0.918/1.00 0.900/1.00.0.8 84 /0 99 8.0.8 69 /0 99 5.0.8 55 /0 99 3.0.8 40 /0 99 0 ¦ Main Optional Parts Model Description Applicable models MAC-397IF-E MA & Control Terminal Interface New A/K control PAC-SE55RA-E Timer Adapter New A/K control PAC-725AD Multiple Remote Controller Adapter (10 sets) New A/K control PAC-SE41TS-E Remote Sensor New A/K control PAC-SA46DS-E Drain Socket PUH-2.5~4 PAC-SA47DS-E Drain Socket PUH-5/6 PAC-292SG-D deiAir Outlet Gu PUH-2.5~6 SDD-50S-E pe for Twin Useibution PistriD PUH-5/6 PAC-SG03TM-E Multi-Function Casement PLH series PAC-SG01KF High Efficiency Filter Element PLH series PAC-SG06SP-E Air Outlet Shutter Plate PLH series -EPAC-SE85DMA n Lift-Up MechanismiDra PCH-3 -EMAPAC-SE86D n Lift-Up MechanismiDra PCH-4~6 PAC-SE81KF-E High Efficiency Filter PCH-3/4 PAC-SE82KF-E High Efficiency Filter PCH-5/6 PAR-SL99B-E ...
Este manual também é adequado para os modelos :Aparelhos de ar condicionado - Mr.Slim PCH-3GAK (659.14 kb)
Aparelhos de ar condicionado - Mr.Slim PCH-GAK (659.14 kb)
Aparelhos de ar condicionado - Mr.Slim PEH-EAK (659.14 kb)
Aparelhos de ar condicionado - Mr.Slim PKH-3FAK (659.14 kb)