Log:
Assessments - 5, GPA: 3.8 ( )

Instruções de Operação Bard, Modelo WL702-A

Fabricante : Bard
Arquivo Tamanho: 707.25 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


1791 Tullie Circle, N.E. Atlanta, GA 30329-2305 Telephone: (404) 636-8400 Fax: (404) 321-5478 NFPA National Fire Protection Association Batterymarch Park P.O. Box 9101 Quincy, MA 02269-9901 Telephone: (800) 344-3555 Fax: (617) 984-7057 Manufactured under the following U.S. patent numbers: 5,485,878; 5,301,744; 5,002,116; 4,924,934; 4,875,520; 4,825,936 Manual 2100-426 Page 1 WALL MOUNT GENERAL INFORMATION AIR CONDITIONER WALL MOUNT MODEL NOMENCLATURE MODEL NUMBER CONTROL MODULES J - Standard on all WL 70 1 – B 09 X X X X X J Models CAPACITY 70 -6 Ton COIL OPTIONS X - Standard 1 - Phenolic Coated Evaporator REVISION VENTILATION OPTIONS 2 - Phenolic Coated Condenser X -Barometric Fresh Air Damper 3 - Phenolic Coated Evaporator VOLTS & PHASE (Standard) and CondenserA -230/208-1 B -Blank-off Plate KW COLOR OPTIONS B -230/208/60-3 M -Motorized Fresh Air Damper 00 -No KW X - Beige C -460/60-3 V -Commercial Room Ventilator 0Z -No KW (Standard) Motorized with Exhaust w/Circuit Breaker OUTLET OPTIONS 1 - White E -Economizer (Internal) - Fully or Pull X - Front (Standard) Modulating with Exhaust Disconnect R -Energy Recovery Ventilator 05 -5 KW 09 -9 KW with Exhaust FILTER OPTIONS 10 -10 KW X - One Inch Throwaway15 -15 KW (Standard) 18 -18 KW W - One Inch Washable P - Two Inch Pleated NOTE: For 0KW and circuit breakers (230/208 V) or pull disconnects (460 V) applications, insert 0Z in the KW field of model number. TABLE 1 ELECTRICAL SPECIFICATIONS Single Circuit Dual Circuit • • • • • • • • Field Wire Ground Models Rated ofNo. Power Circuits MCA MOP Field Wire Size Ground Wire Size MCA MOP Size Wire Size CKT A CKT B CKT A CKT B CKT A CKT B CKT A CKT B WL702-A00,A0Z 203/208-1 1 48 60 8 10 NA NA NA NA NA NA NA NA -A05 230/208-1 1 48 60 8 10 NA NA NA NA NA NA NA NA -A10 230/208-1 1 59 60 6 10 NA NA NA NA NA NA NA NA -A15 230/208-1 1 or 2 85 90 4 8 59 26 60 30 6 10 10 10 WL701-B00,B0Z -B09 -B15 230/208-3 1 1 1 36 36 52 50 50 60 8 8 6 10 10 10 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA WL701-C00,C0Z 1 17 25 12 12 NA NA NA NA NA NA NA NA -C09 460-3 1 17 25 12 12 NA NA NA NA NA NA NA NA -C15 1 26 30 10 10 NA NA NA NA NA NA NA NA Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. Based on 75°C copper wire. All wiring must conform to the National Electric Code (NEC) and all local codes. These "Minimum Circuit Ampacity" values are to be used for sizing the field power conductors. Refer to the National Electric Code (latest version), Article 310 for power conductor sizing. CAUTION: When more than one filed power conductor circuit is run through one conduit, the conductors must be derated. Pay special attention to Note * of Table 310 regarding Ampacity Adjustment Factors when more than 3 conductors are in a raceway. Manual 2100-426 Page 2 Manual 2100-426 Page 3 FIGURE 1 UNIT DIMENSIONS All dimensions in inches. TABLE 2 DIMENSION OF BASIC UNIT FOR ARCHITECTURAL AND INSTALLATION REQUIREMENTS (NOMINAL) Unit Width W Depth D Height H Supply Return E F G I J K L M N O P Q A B C B WL70 42 22-1/4 94-7/8 9-7/8 29-7/8 15-7/8 29-7/8 43-7/8 19 41-5/8 30 42-11/16 37 44-3/4 42-1/2 3-1/4 43 33-7/8 10 TABLE 3 ELECTRIC HEAT TABLE Models WL702-A WL701-B WL701-C 240V-1 208V-1 240V-3 208V-3 460V-3 KW AMPS BTUH AMPS BTUH AMPS BTUH AMPS BTUH AMPS BTUH 5.0 20.8 17,050 18.1 12,800 --- --- --- --- --- --- 9.0 --- --- --- --- 21.7 30,600 18.7 23,030 10.8 30,700 10.0 41.6 34,130 36.2 25,600 --- --- --- --- --- --- 15.0 62.5 51,200 54.1 38,400 36.2 51,200 31.2 38,400 17.3 47,000 BACK VIEW SIDE VIEW FRONT VIEW MIS-1416 SHIPPING DAMAGE Upon receipt of equipment, the carton should be checked for external signs of shipping damage. If damage is found, the receiving party must contact the last carrier immediately, preferably in writing, requesting inspection by the carrier’s agent. GENERAL The equipment covered in this manual is to be installed by trained, experienced service and installation technicians. The refrigerant system is completely assembled and charged. All internal wiring is complete. The unit is designed for use with or without duct work. Flanges are provided for attaching the supply and return ducts. These instructions explain the recommended method to install the air cooled self-contained unit and the electrical wiring connections to the unit. These instructions and any instructions packaged with any separate equipment required to make up the entire air conditioning system should be carefully read before beginning the installation. Note particularly “Starting Procedure” and any tags and/or labels attached to the equipment. While these instructions are intended as a general recommended guide, they do not supersede any national and/or local codes in any way. Authorities having jurisdiction should be consulted before the installation is made. See Page 1 for information on codes and standards. Size of unit for a proposed installation should be based on heat loss calc...

Este manual também é adequado para os modelos :
Aparelhos de ar condicionado - WL701-B (707.25 kb)
Aparelhos de ar condicionado - WL701-C (707.25 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias