Log:
Assessments - 2, GPA: 4.5 ( )

Instruções de Operação Mitsubishi, Modelo Mr. Slim NH41NAD

Fabricante : Mitsubishi
Arquivo Tamanho: 2.08 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Fuze Size (time delay) A 15 15 15 15 20 25 25 25 Min. Ampacity 3 3 3 3 12 15 15 17 Fan Motor F.L.A. 1.8 1.8 2.1 2.4 0.7 0.7 1.3 1.3 Auxiliary Heater A (kW) — — — — 8.4(1.9) 10.8(2.5) 12(2.8) 12(2.8) Airflow Hi-Lo Dry CFM 1,050-850 1,050-850 1,270-990 1,270-990 920-740 920-740 1,270-990 1,270-990 Wet CFM 900-730 900-730 1,100-860 1,100-860 830-670 830-670 1,100-860 1,100-860 Moisture Removal Pints/h 7.2 9.6 11.1 12.6 7.0 9.1 10.9 12.3 Sound Pressure Level Hi-Lo dB(A) 50-43 50-43 52-44 52-44 50-43 50-43 51-45 51-45 Cond. Drain Connection OD in. 1 1 1 1 1 1 1 1 Dimensions W in. 50-7/16 50-7/16 62-1/4 62-1/4 50-7/16 50-7/16 62-1/4 62-1/4 D in. 26-13/16 26-13/16 26-13/16 26-13/16 26-13/16 26-13/16 26-13/16 26-13/16 H in. 10-1/8 10-1/8 10-1/8 10-1/8 10-1/8 10-1/8 10-1/8 10-1/8 Weight lbs. 93 93 115 115 97 97 119 119 OUTDOOR UNIT PU24EK PU30EK PU36EK PU42EK PU24EK PU30EK PU36EK PU42EK External Finish Munsell 5Y 7/1 Sound Pressure Level dB(A) 55 55 55 56 55 55 55 53 Power Supply V, phase, Hz 230, 1, 60 Max. Fuze Size (time delay) A 20 30 30 40 20 30 30 40 Min. Ampacity 16 20 22 27 16 20 22 27 Fan Motor F.L.A. 0.65+0.65 0.65+0.65 0.75+0.75 0.8+0.8 0.65+0.65 0.75+0.75 0.75+0.75 0.8+0.8 Model (Type) NH33NBD NH41NAD NH47NAD NH569NXA NH33NBD NH41NAD NH47NAD NH569NXA Compressor R.L.A.11.5 14 17.5 20 11.5 14 17.5 20 L.R.A.54 73 87 105 54 73 87 105 Crankcase Heater A(W) .17(39) .17(39) .17(39) .17(39) .17(39) .17(39) .17(39) .17(39) Refrigerant Control Capillary Tube Defrost method — — Reverse Cycle Dimensions W in. 34-1/4 34-1/4 38-3/16 38-3/16 34-1/4 38-3/16 38-3/16 38-3/16 D in. 11-5/8 11-5/8 13-9/16 13-9/16 11-5/8 13-9/16 13-9/16 13-9/16 H in. 49-9/16 49-9/16 49-9/16 49-9/16 49-9/16 49-9/16 49-9/16 49-9/16 Weight lbs. 207 208 220 260 202 245 246 268 REMOTE CONTROLLER With Indoor Unit Control Voltage (by built- in transformer) Indoor unit-remote controller: DC 12V, Indoor unit-outdoor unit: DC 12V Figures in parentheses include auxiliary heat. * For 208 volt applications refer to Technical And Service Manual for ratings. MMeeddiiuumm--ttoo--llaarrggee ccaappaacciittyy ccoooolliinngg aanndd hheeaattiinnggffoorr llaarrggee aarreeaa ccoommmmeerrcciiaall aapppplliiccaattiioonnss.. PPLL//PPLLHH Mr. Slim ® CEILING MOUNTED CASSETTES 19 MMeeddiiuumm--ttoo--llaarrggee ccaappaacciittyy ccoooolliinngg aanndd hheeaattiinnggffoorr llaarrggee aarreeaa ccoommmmeerrcciiaall aapppplliiccaattiioonnss.. PPLL//PPLLHH Mr. Slim ® CEILING MOUNTED CASSETTES 19 LARGE AREA COOLING AND HEATING MADE SIMPLE. IntelligentRemote Controller Highly advanced microprocessor technology is one reason why Mitsubishi leads the air comfort category. This ultra-thin microprocessor remote controller with LCD display gives you a variety of functions and options to keep room comfort perfectly balanced. It lets you check Mr. Slim’s operating conditions with just a glance. In the rare case of a malfunction the self-diagnostic system even indicates specific problems for easy repair. • Computerized Dehumidi...

Este manual também é adequado para os modelos :
Aparelhos de ar condicionado - Mr. Slim NH33NBD (2.08 mb)
Aparelhos de ar condicionado - Mr. Slim NH47NAD (2.08 mb)
Aparelhos de ar condicionado - Mr. Slim NH569NXA (2.08 mb)
Aparelhos de ar condicionado - Mr. Slim PC24EK (2.08 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias