Log:
Assessments - 3, GPA: 3.7 ( )

Instruções de Operação Beko, Modelo LG-BKE 7800D

Fabricante : Beko
Arquivo Tamanho: 2.97 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


It lasts for 30 minutes. 5. If you press the AUTO CLEAN button again during the product operation , Auto Clean function will be cancelled. NOTICE . During Auto Clean function, moistures left in indoor units after Cooling Operation or Healthy Dehumidification Operation can be removed. . During Auto Clean function, only Start/Stop button, Plasma button and AUTO CLEAN button are available. Forced operation Operation procedures when the remote control can't be used. The operation will be started if the ON/OFF button is pressed. If you want to stop operation, re-press the button. ON/OFF button Cooling Model Heat pump Model Room Temp. . 24°C 21°C . Room Temp. < 24°C Room Temp. < 21°C Operating mode Cooling Cooling Healthy Dehumidification Heating Indoor FAN Speed High High High High Setting Temperature 22°C 22°C 23°C 24°C Test operation During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room temperature and resets in 18 minutes. During test operation, if remote controller signal is received, the unit operates as remote controller sets. If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound 1 "beep". If you want to stop the operation, re-press the button. 24 Room Air Conditioner Helpful information Fan speed and cooling capacity. The cooling capacity indicated in the specification is the value when the fan speed is set to high, and the capacity will be lower at low or medium fan speed. High fan speed is recommended when you wish to cool the room High Speed quickly. Operating Instructions Auto restart In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions. So there is no need of activating this function by pressing any key or button. In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later. As the compressor starts, the fan speed also resumes its previous setting mode. NOTICE Auto restart function has set enable as factory default. But customer can set up by following this instruction. To be disable function -Press and hold the ON/OFF button for 6 seconds, then the buzzer sound 2 "beep" and the indicator lamp (1) blinks 4 times. To be enable function -Press and hold the ON/OFF button for 6 seconds, then the buzzer sound 2 "beep" and the indicator lamp (1) brights 4 times. ENGLISH Owner's Manual 25 26 Room Air Conditioner Maintenance and Service Maintenance and Service Indoor Unit Before performing any maintenance, turn off the main power to the system. Grille, Case, and Remote Control Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives. Supply power must be disconnected before cleaning the indoor unit. Air filters The air filters behind the front grille should be checked and cleaned once in every 2 weeks or more often if neccessary. 1. Pull the both sides and remove front panel. 2. Pull the filter tab slightly forward to remove the filter. 3. Clean the filter with a vacuum cleaner or warm, soapy water. • If dirt is conspicuous, wash with a solution of detergent in lukewarm water. • If hot water (40°C or more) is used, it may be deformed. 4. After washing with water, dry well in the shade. 5. Re-install the air filter. NEO PLASMA filter (Optional) The NEO PLASMA filter behind the air filters should be checked and cleaned once in every 3 months or more often if necessary. 1. After removing the air filters, pull slightly forward to remove the NEO PLASMA filter. 2. Clean NEO PLASMA filter with the vacuum cleaner. If it is very dirty, wash it with water. 3. Note the cuts of electric discharge lines. 4. Re-install the NEO PLASMA filter to the original position. TRIPLE DEODORIZER filter (Optional) 1. After removing the air filters, pull slightly forward to remove the TRIPLE DEODORIZER filter. 2. Dry in the sunlight for two hours. 3. Re-install the TRIPLE DEODORIZER filter to the original position. NOTICE Don't touch this NEO PLASMA Filter within 10 seconds after opening he inlet grille, it may cause an electric shock. Never use any of the followings: • Water hotter than 40°C Could cause deformation and/or discoloration. • Volatile substances Could damage the surfaces of the air conditioner. Vertical louver Horizontal louver Air filters (behind front panel) Air inlet vent Air outlet vent Gasoline Powder NEO PLASMA Filter TRIPLE DEODORIZING Filter Owner's Manual 27 ENGLISH (Side) (Rear) Air intake vents Air outlet vents Piping Drain Hose TRIPLE DEODORIZING Filter 3 2 Air filter Maintenance and Service Outdoor Unit The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam cleaned. Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs. NOTICE Replac...

Este manual também é adequado para os modelos :
Aparelhos de ar condicionado - LG-BKE 7500D, LG-BKE 7600D, LG-BKE 7650 D, LG-BKE 7700 D, LG-BKE 7800 D (2.97 mb)
Aparelhos de ar condicionado - LG-BKE7650D, LG-BKE7700D (2.97 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias