Log:
Assessments - 3, GPA: 3.3 ( )

Instruções de Operação Beko, Modelo LG-BKE 4600 D, LG-BKE 5605 D

Fabricante : Beko
Arquivo Tamanho: 668.48 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


is not displayed in the remote control and you are not able to control the room temp. either. . During the healthy dehumidification function, the airflow volume is automatically set according to the optimization algorithm responding to the current room temp. status and makes the room condition healthy and comfortable even in the high humidity season. 9 Safety Operating Care and Troubleshooting TipsBeep, BeepBeep, Beep TEMP. TIMEOFF hr. . TEMP. TEMP. TIME hr.TIME hr. TEMP. TIME hr. TEMP. Cooling Healthy Dehumidification Heating (Heat pump model only) To raise the temperature To lower the temperature Press the OFF Time Button. 1. Press the OFF Time Button. 2. Check the OFF Time LED of the room air conditioner. 3. The Timer is programmed by 1 hour each pressing the OFF Time button from 1 hour to 7 hours. OFF Timer control Setting OFF TIMER CONTROL SETTING Press the Start/Stop button. The unit will respond with a beep. To select Heating Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow. Set the temperature higher than the room temperature. The temperature can be set within a range of 16°C~30°Cin 1°C increments. Set the fan speed again with the door of the remote control still closed. You can select the fan speed in four steps–low, medium, high, or CHAOS. Each time the button is pressed, the fan speed mode is shifted. Heating Operation(Heat pump model only) 1 2 3 4 TIME hr. 9 Safety Operating Care and Troubleshooting TipsBeep, BeepBeep, Beep TEMP. TIMEOFF hr. . TEMP. TEMP. TIME hr.TIME hr. TEMP. TIME hr. TEMP. Cooling Healthy Dehumidification Heating (Heat pump model only) To raise the temperature To lower the temperature Press the OFF Time Button. 1. Press the OFF Time Button. 2. Check the OFF Time LED of the room air conditioner. 3. The Timer is programmed by 1 hour each pressing the OFF Time button from 1 hour to 7 hours. OFF Timer control Setting OFF TIMER CONTROL SETTING Press the Start/Stop button. The unit will respond with a beep. To select Heating Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow. Set the temperature higher than the room temperature. The temperature can be set within a range of 16°C~30°Cin 1°C increments. Set the fan speed again with the door of the remote control still closed. You can select the fan speed in four steps–low, medium, high, or CHAOS. Each time the button is pressed, the fan speed mode is shifted. Heating Operation(Heat pump model only) 1 2 3 4 TIME hr. 10 Safety PrecautionsOperating InstructionsCare and MaintenanceTroubleshooting Tips oror or . TEMP. NOTE: . During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely high speed for 30 minutes setting the room temp. automatically to 18°C. It is especially used to cool the room temp. in the shortest time in a hot summer. In heat pump mode the JET COOL function is not available. . In order to return to the normal cooling mode from the JET COOL mode, you just press either the operation mode selection button, airflow volume selection or temp. setting button or the JET COOL button again. Press the Start/Stop button. The unit will respond with a beep. Press the Jet Cool button to operate the speed cooling mode and the unit will operate in super high fan speed on cooling mode for 30 minutes. To cancel the Jet Cool mode, press the Jet Cool button again or the fan speed button or the room temperature setting button and the unit will operate in high fan speed on cooling mode. Jet Cool Operation 1 2 3 TIME hr. 10 Safety PrecautionsOperating InstructionsCare and MaintenanceTroubleshooting Tips oror or . TEMP. NOTE: . During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely high speed for 30 minutes setting the room temp. automatically to 18°C. It is especially used to cool the room temp. in the shortest time in a hot summer. In heat pump mode the JET COOL function is not available. . In order to return to the normal cooling mode from the JET COOL mode, you just press either the operation mode selection button, airflow volume selection or temp. setting button or the JET COOL button again. Press the Start/Stop button. The unit will respond with a beep. Press the Jet Cool button to operate the speed cooling mode and the unit will operate in super high fan speed on cooling mode for 30 minutes. To cancel the Jet Cool mode, press the Jet Cool button again or the fan speed button or the room temperature setting button and the unit will operate in high fan speed on cooling mode. Jet Cool Operation 1 2 3 TIME hr. 11 Safety Operating Care and Troubleshooting Press the Start/Stop Button. (Confirm the unit on operation.) Press the Airflow Direction Control Button and the vertical louvers swing up and down automatically. Press again the Airflow Direction Control Button to set the vertical ...

Este manual também é adequado para os modelos :
Aparelhos de ar condicionado - LG-BKE 4450 D, LG-BKE 5455 D, LG-BKE 4500 D, LG-BKE 5505 D, LG-BKE 4600 D, LG-BKE 5605 D, LG-BKE 470 (668.48 kb)
Aparelhos de ar condicionado - LG-BKE4500 D, LG-BKE5505 D (668.48 kb)
Aparelhos de ar condicionado - LG-BKE 4700 D, LG-BKE 4800 D (668.48 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias