Log:
Assessments - 2, GPA: 3.5 ( )

Instruções de Operação Panasonic, Modelo CU-C18HKD

Fabricante : Panasonic
Arquivo Tamanho: 1.86 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Press to restore the remote control’s default setting. Not used in normal operations. Set the temperature 1°C higher in cool mode than the desired temperature to achieve a 10% power saving. Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode. ENGLISH TOTO SET THE TIMERSET THE TIMER • To turn ON or OFF the unit at a preset time. .......... Select ON or OFF timer. Set the time. Confirm. • To cancel ON or OFF timer, press or then press . • When ON Timer is set, the unit may start earlier (up to 15 minutes) before the actual set time in order to achieve the desired temperature on time. • Timer operation is based on the clock set in the remote control and repeats daily once set. For clock setting, please refer to Remote Control Preparation at back cover. • If timer is cancelled manually or due to power failure, you can restore the previous setting (once power is resumed) by pressing . TO SELECT FAN SPEED (3 OPTIONS) • For AUTO, the indoor fan speed is automatically adjusted according to the operation mode. TO ADJUST AIRFLOW DIRECTION (5 OPTIONS) • Keeps the room ventilated. • If AUTO is set, the louvers swing left/right and up/down automatically. TO ENJOY CLEAN & FRESH AIR • Generates negative ions to produce fresh air effect and attract dust which will then be captured at thepositively charged e-ion filters. TO MONITOR AIR QUALITY Indicator Air Quality BlueCleanOrangeModerateRedDirty• Patrol sensor detects air quality. • When air quality is at dirty level, e-ion operation will startautomatically. TO ENJOY QUIET ENVIRONMENT • This operation reduces airfl ow noise. TO ACHIEVE TEMPERATURE QUICKLY • This operation will stop automatically after 15 minutes. • , , and can be activated in all modes and can be cancelled by pressing therespective button again. • and or and can not be selected at the same time. • and can be activated even when the unit is turned off. In this condition, fan speed and air swing can not be adjusted. OPTIONAL SETTINGS OPTIONAL SETTINGS Patrol starts automatically with the unit switched on with . Press and hold for 5 seconds, then release to disable or restore this setting. Press and hold for 5 seconds to dim or restore the unit’s indicator brightness. Press and hold for approximately 10 seconds to show temperature setting in °C or °F. Press and hold for approximately 5 seconds to show 12-hour (am/pm) or 24-hour time indication. Press to restore the remote control’s default setting. Not used in normal operations. Set the temperature 1°C higher in cool mode than the desired temperature to achieve a 10% power saving. Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode. 6 CAREE & CLLEEANIING WASHING INSTRUCTIONS • Do not use benzene, thinner or scouring powder. • Use only soap ( pH7) or neutral household detergent. • Do not use water hotter than 40°C. HINTS • Clean the fi lter regularly for best performance and to reduce power consumption. • Please consult your nearest dealer for seasonal inspection. FOR SEASONAL INSPECTION AFTER EXTENDED NON-USE • Checking of remote control batteries. • No obstruction at air inlet and air outlet vents. • After 15 minutes of operation, it is normal to have the following temperature difference between air inlet and air outlet vents: Cooling: . 8°C NON SERVICEABLE CRITERIAS TURN OFF POWER SUPPLY AND UNPLUG then CALL Authorized Distributor under the following conditions: • Abnormal noise during operation. • Water/foreign particles have entered the remote control. • Water leaks from Indoor unit. • Circuit breaker switches off frequently. • Power cord becomes unnaturally warm. • Switches or buttons are not functioning properly. FOR EXTENDED NON-USE • Activate e-ion operation for 2~3 hours as an alternative to remove moisture left in the internal parts thoroughly. • Turn off the power supply and unplug. • Remove the remote control batteries. CAUTION e-ion FILTERS • Clean the fi lters regularly. • Wash/rinse the fi lters gently with water to avoid damage to the fi lter surface. • Dry the fi lters thoroughly under the shade, away from fi re or direct sunlight. • Replace any damage fi lter. ACTIVE e-ion GENERATOR FRONT PANEL Raise and pull to remove. Wash gently and dry. Remove ACTIVE e-ion POWER MODULE Clean with dry cotton bud. • Active e-ion generator cleaning is recommended every 6 months. INDOOR UNIT Wipe the unit gently with a soft, dry cloth. ALUMINIUM FIN • Switch off the power supply and unplug before cleaning. • Do not touch the aluminium fi n, sharp parts may cause injury. ENGLISH SymptomSymptom CheckCheck Cooling operation is not working efficiently. • Set the temperature correctly. • Close all doors and windows. • Clean or replace the filters. • Clear any obstruction at the air inlet and air outlet vents. Noisy during operation. • Check if the unit has been installed at an incline. • Close the front panel properly. Remote control does not work. (Display is dim or trans...

Este manual também é adequado para os modelos :
Aparelhos de ar condicionado - CS-C18HKD (1.86 mb)
Aparelhos de ar condicionado - CS-C24HKD (1.86 mb)
Aparelhos de ar condicionado - CU-C24HKD (1.86 mb)
Aparelhos de ar condicionado - CSC18HKD (1.86 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias