Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação LG, Modelo A18AHM UV1

Fabricante : LG
Arquivo Tamanho: 1.71 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


is not displayed on the remote controller and you are not able to control the room temp. either. . During the healthy dehumidification function, the airflow volume is automatically set according to the optimization algorithm responding to the current room temp. status, so that the room condition is kept healthy and comfortable even in the very humid season. Owner's Manual 17 Operating Instructions Heating operation (Heat pump model only) ON Cooling Healthy Dehumidification Auto Heating (Heat pump model only) To lower the temperature To raise the temperature Press the Start/Stop button. The unit will respond with a beep. Open the door of the remote controller. To select Heating Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow. Close the door of the remote controller. Set the temperature higher than the room temperature. The temperature can be set within a range of 16°C~30°C at intervals of 1°C. Set the fan speed again with the door of the remote controller still closed. You can select the fan speed in four steps–low, medium, high and CHAOS. Each time the button is pressed, the fan speed mode is shifted. 1 2 3 4 Natural wind by the CHAOS logic . For fresher feeling, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic. 18 Room Air Conditioner Operating Instructions Jet cool operation or or . During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely high speed for 30 minutes setting the room temp. automatically to 18°C. It is especially used to cool the room temp. quickly in a hot summer. In heat pump mode, neuro fuzzy mode, or auto changeover mode however, the JET COOL function is not available. . In order to return to the normal cooling mode from the JET COOL mode, just press the operation mode selection button, airflow volume selection, temp. setting button or the JET COOL button again. NOTICE Press the Start/Stop button. The unit will respond with a beep. Press the Jet Cool button to operate the speed cooling mode and the unit will operate at super high fan speed on cooling mode for 30 minutes. To cancel the Jet Cool mode, press the Jet Cool button, the fan speed button or the room temperature setting button again and the unit will operate at high fan speed on cooling mode. 1 2 3 Owner's Manual 19 Operating Instructions Jet heat operation (Optional) Cooling Heating (Heat pump model only) Healthy Dehumidification Auto changeover ON or or . During the JET HEAT function at any moment, the A/C starts to blow the heat air at extremely high speed for 60 minutes setting the room temp. automatically to 30°C. It is especially used to heat the room temp. quickly in a cool winter. On cooling, healthy dehumidification mode or auto changeover mode, however, the JET HEAT function is not available. . In order to return to the normal heating mode from the JET HEAT mode, just press the operation mode selection button, airflow volume selection, temp. setting button or the JET HEAT button again. NOTICE Press the Start/Stop button. The unit will respond with a beep. Press the Jet Heat button to operate the speed heating mode and the unit will operate at super high fan speed on heating mode for 60 minutes. To cancel the Jet Heat mode, press the Jet Heat button, the fan speed button or the room temperature setting button again and the unit will operate at high fan speed on heating mode. 1 3 4 Open the door of the remote controller. To select Heating Operation.2 20 Room Air Conditioner Operating Instructions NANO PLASMA purification operation(Optional) Press the Start/Stop button. The unit will respond with a beep. 1 Open the door of the remote controller. Press the NANO PLASMA button. Operation will start when the button is pressed and stop when the button is pressed again. 2 Set the fan speed again with the door of the remote controller closed. You can select the fan speed in four steps-low, medium, high or CHAOS. Each time the button is pressed, the fan speed mode is shifted. . Air purifying operation (NANO PLASMA) can be with cooling, Heating or any other operations. NANO PLASMA Air Purifying Operation only If you press the only NANO PLASMA button, only NANO PLASMA purification function operates. Then, fan speed is low. You can select the fan speed in four steps-low, medium, high or CHAOS. Each time the button ( ) is pressed, the fan speed mode is shifted. 3 Owner's Manual 21 Operating Instructions 2nd F operation ON OFF CANCEL SET ON OFF SET AUTO CLEAN Press the Start/Stop button. The unit will respond with a beep. Open the door of the remote control and press the 2nd Function button to operate functions printed in blue unter buttons. (Check the indication of 2nd function on the display of the remote controller.) These buttons can set the timer as follows: 2nd function disa...

Este manual também é adequado para os modelos :
Aparelhos de ar condicionado - A18AHM NV1 (1.71 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias