Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação LG, Modelo UV18 Inverter

Fabricante : LG
Arquivo Tamanho: 14.18 mb
Arquivo Nome :
Língua de Ensino: plhritenesfrdebgnlhuptdaficsro
Ir para baixar



Facilidade de uso


2. Press 2nd F button. ONOFFTimer Setting 3. Press the ON/OFF TIMER BUTTONS to turn timer on or off. 4. Press the TIME SETTING BUTTONS until the desired time is set. CANCEL 5. To set the selected time, press the TIMER SETTING BUTTONS aiming the remote controller at the signal receptor. To cancel the timer setting CANCEL Check if icon is off. Press the TIMER CANCEL BUTTON aiming the remote controller at the signal receptor. SET(The timer lamp on the air conditioner and the display will go off.) SET NOTE Select one of the following four types of operation. Delay off timer Delay on timer Delay off and on timer Delay on and off timer 12 Convertible & Ceiling suspended Air Conditioner Owner's Manual 13 ENGLISH This operation circulates the air without cooling or heating. It can be activated by pressing the AIR CIRCULATION BUTTON. Once the air circulation is activated you can select the air speed by pressing the INDOOR FAN SPEED SELECTOR BUTTON. The up/down airflow (Vertical airflow) can be adjusted by using the remote controller. 1. Press the START/STOP BUTTON to start the unit. 2. Press CHAOS SWING BUTTON. 3. The louvers will swing up & down automatically. 4. To stop the louver at a desired angle, press again To adjust left/right (Horizontal Airflow) direction Adjust the left/right airflow direction by hand. : While adjusting vertical airflow direction louvers, be careful not to touch the evaporator. WARNING Operating Instructions Vertical / Horizontal Airflow Direction Control • By pressing the CHAOS SWING BUTTON the horizontal air flow direction is changed automatically based on the chaos algorithm to distribute the air in the room evenly and at the same time to make the human body feel most comfortable as if enjoying natural breeze. • Always use the remote controller to adjust the up and down air flow direction. Manually moving the vertical air flow direction louver by hand could damage the mechanism.When the unit is shut off, the up/down airflow direction louver will close the air outlet vent of the system. NOTE CHAOS Air economizes power consumption and prevents overcooling. The fan speed is automatically changed from high to low or vice versa, depending on the ambient temperature. NOTE In case the power comes on again after a power failure, the unit operates automatically to the previous operating conditions. So there is no need of activating this function by pressing any key or button. In the initial mode, the fan operates at a low speed and the compressor starts about 3 minutes later. As the compressor starts, the fan speed also resumes its previous setting mode. : In case of absence for a long time while power failure, turn off main power to avoid undesired Auto restart. WARNING Air Circulation Mode Auto Restart Function 14 Convertible & Ceiling suspended Air Conditioner Maintenance and Service Indoor Unit Before performing any maintenance, turn off the main power to the system. Clean the unit with a soft dry cloth. Do not use bleach or abra...

Este manual também é adequado para os modelos :
Aparelhos de ar condicionado - UV18 NBD (14.18 mb)
Aparelhos de ar condicionado - UV24 Inverter (14.18 mb)
Aparelhos de ar condicionado - UV24 NBD (14.18 mb)
Aparelhos de ar condicionado - UV37 Inv 3 (14.18 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias