Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação Samsung, Modelo AVXTJH028EE

Fabricante : Samsung
Arquivo Tamanho: 3.61 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


4. Connect the power cable{1(L), 2(N)} among the units within maximum length and communication cable(F1, F2) each. 5. Connect V1, V2(for DC12V) and F3, F4(for communication) when installing the wired remote Control. Shield Extension drain hose (No default resource) Drain hose NLNLNLNLELCBMCCB+ ELB Outdoor Unit Wired Remote Control 220-240V~ or EEV kit Indoor Unit 2 Indoor Unit 3 Indoor Unit 1 h ELCB : Essential Installation WARNING Power off before connecting any wires; Indoor PBA will be damaged while V1,V2,F3,F4 short each other. Indoor Unit 6 Indoor Unit 5 Indoor Unit 4 h Ceiling, wall-mounted indoor unit. 6-Ways to connect Drain Hose and Pipe Selecting compressed ring terminal Silver solder Norminal dimensions for cable (mm2) Norminal dimensions for screw (mm) B D d1 E F L d2 t Standard dimension (mm) Allowance (mm) Standard dimension (mm) Allowance (mm) Standard dimension (mm) Allowance (mm) Min. Min. Max. Standard dimension (mm) Allowance (mm) Min. 1.5 4 6.6 ±0.2 3.4 +0.3 -0.2 1.7 ±0.2 4.1 6 16 4.3 +0.2 0 0.7 4 8 2.5 4 6.6 ±0.2 4.2 +0.3 -0.2 2.3 ±0.2 6 6 17.5 4.3 +0.2 0 0.8 4 8.5 4 4 9.5 ±0.2 5.6 +0.3 -0.2 3.4 ±0.2 6 5 20 4.3 +0.2 0 0.9 Specification of electronic wire Knock out Power supply MCCB ELB or ELCB Power cable Earth cable Communication cable Max : 242V Min : 198V XA XA, 30mmA 0.1 sec 2.5mm2 2.5mm2 0.75~1.5mm2 . Decide the capacity of ELCB(or MCCB+ELB) by below formula. The capacity of ELCB(or MCCB+ELB) X[A] = 1.25 X 1.1 X .Ai T X : The capacity of ELCB(or MCCB+ELB). T .Ai : Sum of Rating currents of each indoor unit. T Refer to each installation manual about the rating current of indoor unit. . Decide the power cable specification and maximum length within 10% power drop among indoor units. . ( Coef.35.6.Lk.ik ) < 10% of input voltage[V] 1000.Ak n k=1 T Coef: 1.55 T Lk: Distance among each indoor unit[m], Ak: Power cable specification[mm2], ik: Running current of each unit[A] Indoor Unit Setting Additional Functions 1. Before installing the indoor unit, assign an address to the indoor unit according to the air conditioning system plan. 2. The address of the indoor unit is assigned by adjusting MAIN(SW01, SW02) and RMC(SW03, SW04) rotary switches. SW05K1K2K3K4 SW01SW02SW03SW05SW06SW07SW04 No. Function ON OFF SW05 K1 External room sensor Not use Use K2 Centralized controller Not use Use K3 - - - K4 - - - g K1 OFF Heating mode : Setting temperature compensation value = 0°C Thermo OFF . Fan OFF Setting MAIN Address . The MAIN address is for communication between the indoor unit and the outdoor unit. Therefore, you must set it to operate the air conditioner properly. . You can set the MAIN address from ‘00’ to ‘99’ by mixing SW01 and SW02. The MAIN address from ‘00’ to ‘99’ should differ from each other. . Check the indoor unit address on the plan that you are to install and set the address according to the plan. You may not need to set MAIN address if you selected Auto Address Setting from the outdoor unit: see details on the outdoor unit installation manual. Note When MAIN address is set as “12”.For Example Setting RMC Address . The SW03, SW04 RMC switch is the address setting switch for controlling the indoor unit with the centralized controller. . You must set the SW03, SW04 and K2 switch when using the centralized controller. When RMC address is set as “12”.For Example SW06K5K6K7K8 No. Function ON OFF SW06 K5 Heating Current Temperature Compensation +2°C +5°C K6 Filter Time 1,000 hours 2,000 hours K7 - - - K8 - - - SW07K9K10K11K12 No. Function ON OFF SW07 K9 Indoor Expansion Valve For Heating Stop Fix 80 step 0 or 80 step K10 Wired Remocon Group Master Not Use Use K11 External control Not Use Use K12 Operation output Thermal ON Operation ON SW03SW04 Model specification (Dimension and weight) Dimension and weight Type Model Net dimension (WxDxH) (mm) Net weight (kg) Type Model Net dimension (WxDxH) (mm) Net weight (kg) Indoor unit AVXTJH028EE 720*620*119 16 Outdoor unit (DVM+4) RD080HHXGB 880*765*1695 237 AVXTJH036EE 720*620*119 16 RD100HHXGB 880*765*1695 237 AVXTJH056EE 720*620*119 16 RD120HHXGB 880*765*1695 240 RD140HHXGB 1295*765*1695 280 RD160HHXGB 1295*765*1695 329 RD180HHXGB 1295*765*1695 340 RD200HHXGB 1295*765*1695 349 RD080HRXGB 880*765*1695 243 RD100HRXGB 880*765*1695 243 RD120HRXGB 880*765*1695 243 RD140HRXGB 1295*765*1695 293 RD160HRXGB 1295*765*1695 338 RD180HRXGB 1295*765*1695 349 RD200HHXGB 1295*765*1695 355 Outdoor unit (DVM Mini) RD040MHXEA 940*330*1210 100 RD050MHXEA 940*330*1210 100 RD060MHXEA 940*330*1210 103 RD040MHXGA 940*330*1210 100 RD050MHXGA 940*330*1210 100 RD060MHXGA 940*330*1210 103 QUESTIONS OR COMMENTS? COUNTRY CALL OR VISIT US ONLINE AT AUSTRIA 0810 - SAMSUNG (7267864, € 0.07/min) BELGIUM 02-201-24-18 (Dutch) (French) BOSNIA 051 133 1999 BULGARIA 07001 33 11 , share cost tariff CROATIA 062 SAMSUNG (062 726 786) CZECH 800 - SAMSUNG (800-726786) www.sam...

Este manual também é adequado para os modelos :
Aparelhos de ar condicionado - AVXTJH036EE (3.61 mb)
Aparelhos de ar condicionado - AVXTJH056EE (3.61 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias