Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação Samsung, Modelo AQV24UGBN

Fabricante : Samsung
Arquivo Tamanho: 8.2 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


The air conditioner does not start operating immediately to protect the compressor of the outdoor unit after it has been started. ENGLISH If the heat pump is operating in Heat mode, De-ice cycle is actuated to remove frost from an outdoor unit that may have deposited at low temperatures. The internal fan is switched off automatically and restarted only after the de-ice cycle is completed. cleaning and maintaining _31 appendix TROUBLESHOOTING Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses. PROBLEM The air conditioner does not operate immediately after it has been restarted. The air conditioner does not work at all. The temperature does not change. The cool(warm) air does not come out of the air conditioner. The fan speed does not change. Timer function does not set. Odors permeate in the room during operation. The air conditioner makes a bubbling sound. Water is dripping from the air flow blades. Remote control is not working. SOLUTION • Because of the protective mechanism, the appliance does not start operating immediately to keep the unit from overloading. The air conditioner will start in 3 minutes. • Check that the power plug is properly connected. Insert the power plug into the wall socket correctly. • Check if the circuit breaker is switched off. • Check if there is a power failure. • Check your fuse. Make sure it is not blown out. • Check if you selected Fan mode. Press the Mode button on the remote control to select another mode. • Check if the set temperature is higher(lower) than the current temperature. Press the Temp ..or • button on the remote control to change the set temperature. Press the Temp ..or . button to increase or decrease the temperature. • Check if the air filter is blocked by dirt. Clean the Air filter every two weeks. • Check if the air conditioner has just been turned on. If so, wait 3 minutes. • Check if you selected Auto or Dry mode. The air conditioner automatically adjusts the fan speed to Auto in Auto/Dry mode. • Check if you press the Set/Cancel button on the remote control after you have set the time. • Check if the appliance is running in a smoky area or if there is a smell entering from outside. Operate the air conditioner in Fan mode or open the windows to air out the room. • A bubbling sound may be heard when the refrigerant is circulating through the compressor. Let the air conditioner operate in a selected mode. • Check if the air conditioner has been cooling for an extended period of time with the air flow blades pointed downwards. Condensation may generate due to the difference in temperature. • Check if your batteries are depleted. • Make sure batteries are correctly installed. • Make sure nothing is blocking your remote control sensor. • Check that there are strong lighting apparatus near the air conditioner. Strong light which comes from fluorescent bulbs or neon signs may interrupt the electric waves. AUTO- DIAGNOSTIC FUNCTION This air conditioner has an auto-diagnostic function in case a failure will happen.When error occurs, the Lamp will blink. Before contacting customer call center green number, please ask to installer to make a double check of installation unless there’s a full evidence of SAMSUNG product problem. 32_ appendix OPERATION RANGES The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use. MODE COOLING OPERATIONAL TEMPERATURE INDOOR HUMIDITY IF OUT OF CONDITIONS INDOOR 16.C to 32.C OUTDOOR ..09/12.. 10.C to 43.C 80% or less - - Condensation may occur on the indoor unit with risk to have either water blow off or drops on the floor. Internal protection triggers and the air conditioner will stop. Condensation may occur on the indoor unit with risk to have either water blow off or drops on the floor. ..18/24.. -10.C to 43.C HEATING 27.C or less ..09/12.. -10.C to 24.C ..18/24.. -15.C to 24.C DRYING 16.C to 32.C ..09/12.. 10.C to 43.C ..18/24.. -10.C to 43.C The standardized temperature for heating is 7.C. If the outdoor temperature drops to 0.C or below, the heating capacity can be reduced depending on the temperature condition. If the cooling operation is used at over 32.C(indoor temperature), it does not cool at its full capacity. ENGLISH appendix _33 QUESTIONS OR COMMENTS? COUNTRY CALL OR VISIT US ONLINE AT AUSTRIA 0810 -SAMSUNG (7267864, € 0.07/min) BELGIUM 02-201-24-18 (Dutch) (French) CZECH 800 -SAMSUNG (800-726786) DENMARK 70 70 19 70 FINLAND 030 -6227 515 FRANCE 01 48 63 00 00 GERMANY 01805 -SAMSUNG(726-7864 € 0,14/Min) HUNGARY 06-80-SAMSUNG(726-7864) ITALIA 800-SAMSUNG(726-7864) LUXEMBURG 261 03 710 NETHERLANDS 0900-SAMSUNG (0900-7267864) (€ 0,10/Min) NORWAY 815-56 480 POLAN...

Este manual também é adequado para os modelos :
Aparelhos de ar condicionado - AQV24UGBX (8.2 mb)
Aparelhos de ar condicionado - AVXWVH071EE (8.2 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias