Instruções de Operação Johnson Controls, Modelo TCGF24
Fabricante : Johnson Controls Arquivo Tamanho: 106.09 kb Arquivo Nome : 19d496f5-dc6f-4e51-8cbe-955397bd20bf.pdf
Língua de Ensino:
|
|
|
|
Ir para baixar
Facilidade de uso
Overcurrent Device Amps 2 25 30 30 40 45 60 Min. Overcurrent Device Amps 3 20 20 20 25 30 40 Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll Compressor Amps Rated Load 12.8 14.1 14.1 17.9 21.1 27.5 Locked Rotor 58 73 77 112 115 135 Crankcase Heater No No No No No No Fan Motor Amps Rated Load .8 .8 1.5 1.5 1.5 1.5 Fan Diameter Inches 22 22 22 24 24 24 Fan Motor Rated HP 1/8 1/8 1/4 1/4 1/4 1/4 Nominal RPM 1075 1075 850 850 850 850 Nominal CFM 2750 2800 3200 3600 3600 3700 Coil Face Area Sq. Ft. 13.1 17.4 17.4 20.0 21.4 24.0 Rows Deep 1 1 1 1 1 1 Fin / Inches 23 23 23 23 23 23 Liquid Line Set OD (Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line Set OD (Field Installed) 3/4 3/4 3/4 7/8 7/8 1 1/8 Unit Charge (Lbs. - Oz.) 4 3 - 2 3 - 7 3 - 10 4 - 4 4 - 9 5 - 9 Charge Per Foot, Oz. 0.62 0.62 0.62 0.67 0.67 0.75 Operating Weight Lbs. 128 130 145 172 180 199 1. Rated in accordance with ARI Standard 110, utilization range “A”. 2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection. 3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection. 4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value. All dimensions are in inches. They are subject to change BCA without notice. Certified dimensions will be provided upon request. Unit Model Dimensions (Inches) Refrigerant Connection Service Valve Size A1 B C Liquid Vapor 24 28 29 29 3/8” 3/4” 30 36 29 29 36 36 29 29 42 34 33.6 33.6 7/8” 48 36 33.6 33.6 60 40 33.6 33.6 7/8”2 1. Including Fan Guard. 2. Adapter fitting required for 1-1/8” line set. Johnson Controls Unitary Products 362564-UTD-B-0708 362564-UTD-B-0708 R-410A SYSTEM CHARGING PROCEDURE Additional R-410A Charge / Orifice Size for Various Matched Systems Outdoor Unit TCGF24S41S1 TCGF30S41S1 TCGF36S41S1 TCGF42S41S1 TCGF48S41S1 TCGF60S41S1 Required Orifice or TXV 1 1TVM902 1TVM903 1TVM903 1TVM903 1TVM905 1TVM906 Factory Charge, lbs-oz 3 - 2 3 - 7 3 - 10 4 - 4 4 - 9 5 - 9 Indoor Coil2,3,4 Additional Charge, Oz FC/MC/PC24A3X 5 – – – – – FC/MC/PC24B3X 5 – – – – – FC/MC/PC30A3X 12 2 – – – – FC/MC/PC30B3X 12 2 – – – – FC/MC/PC32A3X 16 10 – – – – FC/MC/PC35B3X 16 10 – – – – FC/MC/PC35C3X 16 10 – – – – FC/MC/PC36A3X 8 4 – – – – FC/MC/PC36B3X 8 4 8 – – – FC/MC/PC36C3X 8 4 1 – – – FC/MC/PC37A3X 24 19 15 – – – FC/MC/PC43B3X 24 19 15 5 – – FC/MC/PC43C3X 24 19 15 5 – – FC/MC/PC48C3X 40 32 15 17 16 – FC/MC/PC48D3X 40 32 27 17 16 – FC/MC/PC60D3X – – – 17 16 0 FC/MC62D3X – – – 25 26 18 UC24A3X 8 – – – – – UC24B3X 8 – – – – – UC30A3X 8 4 – – – – UC30B3X 8 4 – – – – UC36A3X – – – – – – UC36B3X – – – – – – UC36C3X – – – – – – UC42B3X – – – – – – UC42C3X – – – – – – UC48C3X – – – – – – UC48D3X – – – – – – UC60C3X – – 12 – – – UC60D3X – – 12 – – – HC18A3X – – – – – – HC30A3X 10 – – – – – HC36B3X 16 11 8 – – – HC42C3X 25 19 15 6 – – HC60D3X – – – 0 0 0 HD24*3X 16 – – – – – HD36*3X 18 – – – – – HD48*3X 51 42 36 24 25 – HD60*3X – – – – 24 – AHP18B3X – – – – – – AHP24B3X 3 – – – – – AHP30B3X 16 – – – – AHP36C3X – 19 15 – – – Johnson Controls Unitary Products 362564-UTD-B-0708 R-410A SYSTEM CHARGING PROCEDURE AHP42C3X – – – – – – AHP/SHP60D3X – – – – 1 – AV24B3X 3 – – – – – AV36C3X 25 19 15 – – – AV/SV48D3X – – 9 0 1 – AV/SV60D3X – – – 0 1 0 F4FP024 0 – – – – – F4FP030 3 0 – – – – F4FP036 – 8 5 – – – F4FP040 – 12 8 – – – F4FP042 – – 8 0 – – F4FP045 – – 9 2 – – F5FP048 – – 20 10 11 – F5FP060 – – 20 10 11 – F4FV060 – – 9 10 1 – Additional R-410A Charge / Orifice Size for Various Matched Systems (Continued) Outdoor Unit TCGF24S41S1 TCGF30S41S1 TCGF36S41S1 TCGF42S41S1 TCGF48S41S1 TCGF60S41S1 Required Orifice or TXV 1 1TVM902 1TVM903 1TVM903 1TVM903 1TVM905 1TVM906 Factory Charge, lbs-oz 3 - 2 3 - 7 3 - 10 4 - 4 4 - 9 5 - 9 Indoor Coil2,3,4 Additional Charge, Oz See Caution below See Caution below See Caution below See Caution below See Caution below See Caution below See Caution below See Caution below See Caution below FOOTNOTES: 1. Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224. 2. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications. 3. A TXV kit must be used with these coils to obtain system performance. Note: If a TXV is factory installed on the coil, it must be replaced with the listed TXV 4. Refer to Technical Guide for actual system performance and matches. PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of interconnecting line tubing. 2. Verify the TXV or orifice and additional charge required for specific evaporator coil in the system using the above table. 3. Add additional charge for the amount of interconnecting line tubing greater t...
Escreva a sua própria avaliação do dispositivo
|
|