Log:
Assessments - 8, GPA: 4.3 ( )

Instruções de Operação Honeywell, Modelo AMH-10000E

Fabricante : Honeywell
Arquivo Tamanho: 4.2 mb
Arquivo Nome : ed63a15c-e21a-4f92-b059-9d161c98291e.pdf
Língua de Ensino: ruplsvhritentresfrdeetnlhuptdaficslvlt
Ir para baixar



Facilidade de uso


AMH-10000EAMH-12000E GR ....... ........... SA AMH-10000E/AMH-12000E AMH-10000E/AMH-12000E CONTENTS ENGLISH INHALT DEUTCH CONTENU FRANCAIS INDICE ITALIANO INDICE ESPANOL CONTEUDO PORTUGUESE INHOUD NEDERLANDS INNEHALL SVENSKA INNHOLD NORSK INDHOLD DANSK SISALLYSLUETTELO SUOMI SPIS TRESCI POLSKI TARTALOMJEGYZEK MAGYAR OBSAH CESKY SADRZAJ HRVATSKY VSEBINA SLOVENSKO SISUKORD EESTI TURINYS LIETUVIU SATURA RADITAJS LATVIESU FIHIRST TURKCE СОДЕРЖАНИЕ PУCCKИЙ ........... E..HNIKA 481 16 0 4 83 36394 45495356596 65687 7579 83 1 AMH-10000E/AMH-12000E 2 8 7 3 6 4 5 9 10 11 12 13 AMH-10000E/AMH-12000E Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 STOP Fig. 9 1.5V 1.5V 1.5V 1.5V Fig. 10 Fig. 11 OPERATING INSTRUCTIONS: CONTROL PANEL LCD Display Power Control Fan Speed Control Timer Control Mode Control Cooling Mode High Fan Speed Dehumidify Mode Med Fan Speed Fan Only Mode Low Fan Speed Display Set Temperature Warning Light - the machine will stop running Display Timer Setting of Auto Switch On/Off Power Control Fan Speed Control On/Off Timer Control Farenheit/ Celsius Button LCD Display Time/ Temperature Set Control Mode Control AMH-10000E AC 22 0-240V ~ 50 Hz 1200W 5.2A 2.9kW (10000 B.T.U.) 1.8 l/h R-407C 24 hour 480mm W x 900mm H x 400mm D 35 kg AMH-12000E AC 22 0-240V ~ 50 Hz 1400W 6.3A 3.5kW (12000 B.T.U.) 2.0 l/h R-410A 24 hour 480mm W x 900mm H x 400mm D 38 kg ENGLISH ENGLISH IMPORTANT SAFETY INSTRUCTIONS Read through all the instructions before starting to use the air- conditioner. Keep this manual in a safe place for future reference. 1. Supervision is needed when the air-conditioner is used anywhere near children. This appliance is not intended for use by children or other persons without assistance or supervision if their physical, sensory or mental capabilities prevent them from using it safely. 2. Do not use the air-conditioner outdoors. 3. Stand the air-conditioner upright on a firm, even surface. Make sure it is standing securely so that it cannot tilt or fall over. Water can damage furniture and floor coverings. 4. Unwind the power cord completely. An incompletely unwound power cord can lead to overheating and cause a fire. 5. If the power cord of the air-conditioner is damaged, it must be repaired by a workshop that is approved by the manufacturer, as special tools are needed. 6. Do not use an extension cord or a variable speed controller. This can lead to overheating, fire or electric shock. 7. Only connect the air-conditioner with a single-phase earthed power socket with the current stipulated on the type plate. 8. Switch the air-conditioner off and always pull the power plug out of the power socket when the air-conditioner is not in use, or when it is moved, handled or cleaned. Do not tug at the cord when disconnecting the power plug. 9. The air-conditioner functions best at room temperatures of up to 35°C. 10. Do not use the air-conditioner near easily inflammable gases or materials, near an open fire, or in a location where oil or water could splash. Do not spray insecticides or similar substances onto the air-conditioner. Make sure that the air-conditioner is not exposed to direct sunshine. Do not operate the air-conditioner in a hothouse or a laundry, or near a bathtub, a shower or a swimming- pool. 11. Do not use the air-conditioner outdoors. The air-conditioner is intended only for domestic use indoors, in accordance with the user manual, and is not intended for industrial use. 12. Before starting to operate the air-conditioner, make sure that the air intakes (3, 8) and air outlet (1) are open. The air-conditioner must not be positioned behind curtains or drapes, or behind other objects or obstacles which could hinder the air circulation. Make sure that no objects can get into the air intakes (3, 8) and air outlet (1), as this can lead to overheating, fire or electric shock. 13. Do not direct the air outlet (1) directly towards people, plants, pets, walls, furnishings or objects. 14. Do not pull the power plug out of the power socket when the air-conditioner is in use. First press the power button to the OFF position. 15. After switching the air-conditioner off, wait for 3-5 minutes before switching it back on again, as the compressor could otherwise be damaged. 16. Do not immerse the air-conditioner in water or any other liquids and do not pour water or any other liquids over the unit or into the air intake (8) or air outlet (1). 17. Clean the air-conditioner regularly by following the cleaning instructions. 18. When you take the air filter out of the air-conditioner, make sure that you do not touch any metal parts. These are sharp-edged and could cause injury. Do not use the air-conditioner when the air filter and air intakes (3, 8) are not installed. 19. If the power cord of the air-conditioner is damaged, it must be repaired by a workshop that is approved by the manufacturer, as special tools are needed. 20. Always transport the air-conditioner in an upright position. If this is no...

Este manual também é adequado para os modelos :
Aparelhos de ar condicionado - AMH-12000E (4.2 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias