Facilidade de uso
Visit us on the web at Additional rating information can be found at DESCRIPTION The 14.5 SEER Series condensing unit is the outdoor part of a versatile system of air conditioning. It is designed to be custom- matched with one of UPG’s complete line of evaporator sections, with each serving a specific function. Matching Air Handlers are available for upflow, downflow, or horizontal applications to provide a complete system. Electric Heaters are available, if required. Add-on coils are available for use with upflow, downflow, or horizontal furnaces and air handlers. WARRANTY Single Phase Units: 5-year limited parts warranty. 10-year limited compressor warranty. FEATURES • QUALITY CONDENSER COILS - The coil is constructed of aluminum microchannel tubing and enhanced aluminum fins for increased efficiency and corrosion protection. • PROTECTED COMPRESSOR - The compressor is internally protected against high pressure and temperature and externally by a factory installed high pressure switch. This protects the compressor if undesirable operating conditions occur. A liquid line filter-drier further protects the compressor. • DURABLE FINISH - The cabinet is made of pre-painted steel. The pre-treated galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. Special primer formulas and matted-textured finish insure less fading when exposed to sunlight. • LOWER INSTALLED COST -Installation time and costs are reduced by easy power and control wiring connections. Available in sweat connect models only. The unit contains enough refrigerant for matching indoor coils and 15 feet of interconnecting piping. The small base dimension means less space is required on the ground or roof. • TOP DISCHARGE -The warm air from the top mounted fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications. • LOW OPERATING SOUND LEVEL - The upward air flow carries the normal operating noise away from the living area. The rigid top panel effectively isolates any motor sound. Isolated compressor mounts minimize compressor operating sounds. • LOW MAINTENANCE - Long life permanently lubricated motor-bearings need no annual servicing. • EASY SERVICE ACCESS -Fully exposed refrigerant connections, and a single panel covering the electrical controls make for easy servicing of the unit. • SECURED SERVICE VALVES - Secured re-usable service valves are provided on both the liquid and vapor sweat connections for ease of evacuating and charging. • U.L. and C.U.L. listed -approved for outdoor application. Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 413432-YTG-A-0608 Physical and Electrical Data MODEL TCGF24S41S1 TCGF30S41S1 TCGF36S41S1 TCGF42S41S1 TCGF48S41S1 TCGF60S41S1 Unit Supply Voltage 208-230V, 1., 60Hz Normal Voltage Range 1 187 to 252 Minimum Circuit Ampacity 16.8 18.4 19.09 23.9 27.9 35.9 Max. Overcurrent Device Amps 2 25 30 30 40 45 60 Min. Overcurrent Device Amps 3 20 20 20 25 30 40 Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll Compressor Amps Rated Load 12.8 14.1 14.1 17.9 21.1 27.5 Locked Rotor 58 73 77 112 115 135 Crankcase Heater No No No No No No Fan Motor Amps Rated Load .8 .8 1.5 1.5 1.5 1.5 Fan Diameter Inches 22 22 22 24 24 24 Fan Motor Rated HP 1/8 1/8 1/4 1/4 1/4 1/4 Nominal RPM 1075 1075 850 850 850 850 Nominal CFM 2750 2800 3200 3600 3600 3700 Coil Face Area Sq. Ft. 13.07 17.44 17.44 20.03 21.37 24.04 Rows Deep 1 1 1 1 1 1 Fin / Inches 23 23 23 23 23 23 Liquid Line Set OD (Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line Set OD (Field Installed) 3/4 3/4 3/4 7/8 7/8 1 1/8 Unit Charge (Lbs. - Oz.) 4 3 - 2 3 3 - 10 4 - 4 4 - 9 5 - 9 Charge Per Foot, Oz. 0.62 0.62 0.62 0.67 0.67 0.75 Operating Weight Lbs. TBD 130 145 172 180 199 1. Rated in accordance with ARI Standard 110, utilization range “A”. 2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection. 3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection. 4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value. All dimensions are in inches. They are subject to change BCA without notice. Certified dimensions will be provided upon request. Unit Model Dimensions (Inches) Refrigerant Connection Service Valve Size A1 B C Liquid Vapor 24 28 29 29 3/8” 3/4” 30 36 29 29 36 36 29 29 42 34 33.6 33.6 7/8” 48 36 33.6 33.6 60 40 33.6 33.6 7/8”2 1. Including Fan Guard. 2. Adapter fitting required for 1-1/8” line set. Johnson Controls Unitary Products 413432-YTG-A-0608 Additional R-410A Charge / Orifice Size for Various Matched Systems Outdoor Unit TCGF24S...
Este manual também é adequado para os modelos :Aparelhos de ar condicionado - 14.5 SEER TCGF60 (339.18 kb)