Facilidade de uso
Models shown at 230/460 Volts with side duct connections. 2. Includes allowances for a wet evaporator coil, 1” filters, and the heat exchangers. Refer to STATIC RESISTANCE Table for resistance values on applications other than gas / electric units with side duct airflows. TABLE 11: SUPPLY AIR BLOWER PERFORMANCE (3-5 TON) SIDE DUCT APPLICATION UNIT TONNAGE MOTOR SPEED AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CFM WATTSCFM WATTSCFM WATTSCFM WATTSCFM WATTSCFM WATTSCFM WATTSCFM WATTSCFM WATTS HI 1535 320 1493 335 1452 349 1416 363 1377 376 1340 390 1299 403 1260 417 1219 430 MED/HI 1444 263 1398 276 1355 290 1315 303 1271 316 1227 329 1179 343 1125 358 1053 374 32 MED 1300 208 1254 221 1211 234 1166 246 1119 258 1070 272 1006 288 939 303 897 313 MED/LOW 1197 171 1149 183 1102 195 1050 207 996 220 930 235 869 248 ---- LOW 1049 130 968 134 908 145 838 158 ---------- HI 2056 636 2017 696 1978 714 1942 734 1906 749 1864 764 1815 769 1728 743 1582 685 MED/HI 1866 539 1832 557 1795 571 1754 585 1722 602 1679 619 1636 638 1582 653 1508 639 42 MED 1680 408 1641 426 1594 438 1558 455 1517 472 1469 490 1415 505 1370 521 1337 536 MED/LOW 1582 362 1541 380 1495 391 1465 406 1426 423 1377 440 1326 455 1292 469 1247 485 LOW 1300 223 1258 237 1202 247 ------------ HI 2256 883 2258 931 2247 950 2223 964 2182 979 2125 971 2044 940 1958 898 1864 854 MED/HI 2145 771 2127 784 2119 808 2089 826 2051 844 2014 859 1965 861 1896 843 1801 806 52 MED 2020 637 1999 656 1985 675 1947 696 1910 715 1876 730 1832 740 1793 756 1725 748 MED/LOW 1757 413 1713 432 1677 451 1639 468 1597 479 1559 497 1521 513 1472 523 -- LOW 1570 327 1536 339 1499 356 ------------ 1. Includes allowances for a wet evaporator coil, 1” filters, and the heat exchangers. Refer to STATIC RESISTANCES Table for resistance values. 2. Side Duct application (230 Volts) Unitary Products Group 254597-YTG-B-0507 254597-YTG-B-0507 MODEL SIZE BLOWER RANGE (RPM) MOTOR1 ADJUSTABLE MOTOR PULLEY FIXED BLOWER PULLEY BELT (NOTCHED) HP FRAME DESIGNATION OUTSIDE DIA. (IN.) PITCH DIA. (IN.) BORE (IN.) DESIGNATION OUTSIDE DIA. (IN.) PITCH DIA. (IN.) BORE (IN.) DESIGNATION PITCH LENGTH (IN.) QTY. 3 TON 790/1120 1 1/2 56 1VL40 2.7-3.7 2.4-3.4 5/8 AK61 5.9 5.7 1 A36 37.3 1 4 TON 790/1120 1 1/2 56 1VL40 2.7-3.7 2.4-3.4 5/8 AK61 5.9 5.7 1 A36 37.3 1 5 TON 850/1220 1 1/2 56 1VL40 2.7-3.7 2.4-3.4 5/8 AK56 5.4 5.2 1 A36 37.3 1 1. All motors have solid bases and are inherently protected. these motors can be selected to operate into their service factor because they are located in the moving air, upstream of any heating device. TABLE 13: STATIC RESISTANCES DESCRIPTION RESISTANCE, IWG CFM 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 ECONOMIZER1 3 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 0.23 0.26 0.30 ELECTRIC HEATERS1 7-15KW 0.04 0.05 0.06 0.07 0.08 0.10 0.12 0.14 0.16 0.19 0.22 20-30KW 0.06 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 0.23 0.26 BOTTOM DUCT CONNECTIONS1 0.06 0.07 0.08 0.09 0.10 0.11 0.12 0.14 0.16 0.19 0.22 COOLING ONLY2 0.08 0.10 0.12 0.14 0.16 0.18 0.20 0.23 0.26 0.29 0.32 1. Deduct these resistance values from the available external static pressure shown in SUPPLY AIR BLOWER PERFORMANCE Tables. 2. Add these resistance values to the available static resistance values on SUPPLY AIR BLOWER PERFORMANCE Tables. 3. The pressure through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct system is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. TABLE 14: ELECTRIC HEATER CFM LIMITATIONS UNITMODEL SIZE NOMINAL TONS VOLTAGE MINIMUM SUPPLY AIR CFM HEATER SIZE NOMINAL KW 5 7 10 15 20 30 3 208/230-3-60 1100 1100 1200 1200 1300 - 460-3-60 -1100 1200 1200 1300 - 575-3-60 --1200 1200 1300 - 4 208/230-3-60 1300 1300 1300 1300 1300 - 460-3-60 -1300 1300 1300 1300 - 575-3-60 --1300 1300 1400 - 5 208/230-3-60 1600 1600 1600 1600 1600 1600 460-3-60 -1600 1600 1600 1600 1600 575-3-60 --1600 1600 1600 1800 Unitary Products Group 254597-YTG-B-0507 254597-YTG-B-0507 MODEL TONNAGE VOLTAGE COMPRESSORS OD FAN MOTOR FLA ID BLOWER MOTOR FLA CONV OUTLET FLA ELECTRIC HEATER MODEL NO. HEATER KW HEATER AMPS MIN. CIRCUIT AMPACITY (AMPS) MAX. FUSE/ BRKR1 SIZE (AMPS) RLA EACH LRA EACH DH036 208-3-60 13.1 110.0 2.3 8.0 0.0 None -- 26.7 35 2CE045105252 4.0 11.1 26.7 35 2CE045107252 5.6 15.5 29.4 35 2CE04511025 8.0 22.2 37.8 40 2CE04511525 11.9 33.0 51.3 60 2CE04512025 15.9 44.1 65.2 70 230-3-60 13.1 110.0 2.3 8.0 0.0 None -- 26.7 35 2CE045105252 5.3 12.7 26.7 35 2CE045107252 7.5 18.0 32.6 35 2CE04511025 10.6 25.5 41.9 45 2CE04511525 15.9 38.2 57.8 60 2CE04512025 21.2 51.0 73.7 80 DH048 208-3-60 13.1 110.0 2.3 10.6 0.0 None -- 29.3 40 2CE045105252 4.0 11.1 29.3 40 2CE045107252 5.6 15.5 32.7 40 2CE04511025 8.0 22.2 41.0 45 2CE04511525 11.9 33.0 54.5 60 2CE04512025 15.9 44.1 68.4 70 230-3-60 13.1 110.0 2.3 10.6 0.0 None -- 29.3 40 2CE045105252 5.3 12.7 29.3 40 2CE045107252 7.5 18.0 3...
Este manual também é adequado para os modelos :Aparelhos de ar condicionado - CSA 60 (603.8 kb)
Aparelhos de ar condicionado - CSA DH 036 (603.8 kb)