Log:
Assessments - 2, GPA: 4.5 ( )

Instruções de Operação York, Modelo 359583-YTG-B-0208

Fabricante : York
Arquivo Tamanho: 316.39 kb
Arquivo Nome : 6b8c7e6a-1e37-4465-93b4-050b1028ed65.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Horizontal units are designed for suspended ceiling mounting. Horizontal models are shipped with ‘straight-through’ evaporator fan discharge as standard. Fan orientation is field convertible to side discharge. Vertical units are designed for free-standing floor mounting. All units are completely factory wired and pre-piped. Water supply, water outlet, and condensate drain connections are via female pipe thread fittings. CABINET All cabinets are completely constructed of 18 Ga. corrosion resistant “Galvalume” coated steel. The horizontal units are complete with integral hanger channels. The entire unit interior (both evaporator and condensing section) is insulated with 1/2” thick, 2 lb. density insulation. Service panels are equipped with lifting handles for ease of removal and handling. All units provide excellent service access to the reversing valve, thermal expansion valve, and compressor with the unit remaining in location. An integral duct collar is provided on the blower discharge opening. An optional discharge plenum is available for Vertical models. REFRIGERANT CIRCUITS All models utilize hermetic rotary or reciprocating type compressors. Compressors are mounted on rubber isolators to minimize vibration transmission. Internal overload protection is provided. External high pressure and low pressure cutout switches are included in each compressor control circuit. Each refrigeration circuit includes an adjustable biflow thermal expansion valve (with external equalizer), bi-flow liquid line filter drier, and service gauge ports. The reversing valve is a pilot operated, sliding piston type with a replaceable magnetic solenoid coil. The refrigerant-to-air heat transfer coils are constructed of internally enhanced copper tubes mechanically bonded to enhanced aluminum plate fins. The evaporator coil is employed in a draw-through configuration. Large evaporator coil face area minimizes potential water blow-off. The coaxial refrigerant-to-water heat exchangers feature a convoluted inner tube design for high heat transfer efficiency. Standard models feature a copper inner tube surrounded by a steel outer tube, and carry a 400 psig water side working pressure rating. 359583-YTG-B-0208 ELECTRICAL/CONTROLS All units are completely factory wired with all necessary operating controls. A 24 volt control circuit, with oversize transformer, is provided for field connection. Units are designed to operate with conventional thermostat control interface. The reversing valve solenoid coil shall be energized in cooling mode only. A manual reset is provided on each compressor control circuit in the event of high/low pressure cutout. A time delay relay for anti-short cycle protection is standard in all units. An optional condensate overflow switch is avail- able, complete with an alarm output contact. An optional remote management package allows the unit to be controlled by an external source. FILTERS All models are shipped with 1 inch thick throw-away filters factory installed. Filters are accessible from either side of unit. PRODUCT NOMENCLATURE Water Cooled Package Heat Pump and AC Model Number Nomenclature 2 Johnson Controls Unitary Products 359583-YT G-B-0208 TABLE 1: GENERAL DATA Model Series 007 009 012 018 024 0Э0 0Э6 048 060 Nominal Cooling (Ton) 0.5 0.75 1.0 1.5 2.0 2.5 Э.0 4.0 5.0 Cooling Performance Cooling Capacity (BTUH) 7000 9000 12800 18100 24200 Э0800 Э6100 48200 59000 EER 12.4 1Э.0 12.6 14.4 14.4 1Э.5 14.2 14.0 12.6 Heating Capacity (BTUH) 8800 10700 14800 20900 27500 Э5200 41400 56000 72000 COP 4.2 4.4 4.2 4.5 4.6 4.4 4.6 4.6 4.4 Design CFM 200 Э00 400 600 800 1000 1200 1600 2000 Nominal Waterflow (gpm) 1.5 2.25 Э.0 4.5 6.0 7.5 9.0 12.0 15.0 Compressor-Type Rotary Rotary Rotary Recip. Recip. Recip. Recip. Recip. Recip. Number Used 1 1 1 1 1 1 1 1 1 Air Coil- Type Enhanced Copper Tubes, Enhanced Aluminum Fins Face Area (sq. Ft.) 1.00 1.00 1.00 1.51 2.56 2.56 2.88 4.Э8 5.00 Rows/FPI 2/14 2/14 Э/14 Э/14 Э/14 Э/14 Э/14 Э/14 Э/14 Water Coil - Type Co-Axial Water Connection Size 1/2” FPT 1/2” FPT 1/2” FPT 3/4” FPT 3/4” FPT 3/4” FPT 3/4” FPT 3/4” FPT 1” FPT Drain Connection Size 3/4” FPT Direct Drive Fan-Type Centrifugal, Forward Curved Number Used 1 1 1 1 1 1 1 1 1 Diameter x Width (in) 9x4 9x4 9x4 9x6 9x7 9x7 9x7 10x9 10x9 Motor HP /Speed 0.10/Э 0.10/Э 0.17/Э 0.25/Э 0.25/Э 0.ЭЭ/Э 0.50/Э 0.75/Э 1.0/Э Filters Horizontal Model - Qty. Size 1-14x16x1 1-14x16x1 1-14x16x1 1-16x20x1 1-18x25x1 1-18x25x1 1-20x25x1 2-20x20x1 1-20x20x1 1-20x25x1 Vertical Models - Qty. Size 1-14x16x1 1-14x16x1 1-14x16x1 1-16x20x1 1-18x25x1 1-18x25x1 1-20x25x1 1-16x25x1 1-14x25x1 1-18x25x1 1-16x25x1 Weight Operating 1Э0 1Э5 155 180 215 2Э5 260 Э25 Э45 Shipping 145 150 170 195 2Э0 255 280 Э45 Э65 NOTE: 1. Performance calculated in accordance with ARI/ISO Standard 13256-1 for Water Loop Application. 2. Cooling capacities are rated at enter...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias