|
Facilidade de uso
To replace: Hook the tabs on the front grille even with the tabs on the case and snap into place. Replace the screws and filter. Front Grille Care and cleaning of the air conditioner. Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support Outdoor Coils The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot they may be professionally steam cleaned, a service available through your GE service outlet. Grille and Case Turn the air conditioner off and remove the plug from the wall outlet before cleaning. To clean, use water and a mild detergent. Do not use bleach or abrasives. Grille Tab Grille Tab 7 On some models On some models Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions Care and cleaning of the air conditioner. To maintain optimum performance, clean the filter at least every 30 days. Air Filter FRONTFRONT Dirty filter—Needs cleaning Clogged filter—Greatly reduces cooling, heating and airflow. Turn the air conditioner off before cleaning. The most important thing you can do to maintain the air conditioner is to clean the filter at least every 30 days. A clogged filter reduces cooling, heating and air flow. Keeping the air filter clean will: ¦ Decrease cost of operation. ¦ Save energy. ¦ Prevent clogged heat exchanger coils. ¦ Reduce the risk of premature component failure. To clean the air filters: ¦ Vacuum off the heavy soil. ¦ Run water through the filters. ¦ Dry thoroughly before replacing. To remove the air filter, on some models: Carefully pull the tab forward, up and out. To replace the air filter: Replace the clean filter by pushing it back into place. To remove the air filter, on other models: Pull it down. CAUTION: Do not operate the air conditioner without the filter in place. If a filter becomes torn or damaged it should be replaced immediately. Operating without the filter in place or with a damaged filter will allow dirt and dust to reach the indoor coil and reduce the cooling, heating, airflow and efficiency of the unit. Replacement filters are available from your salesperson, GE dealer, GE Service and Parts Center or authorized Customer Care® servicers. 8 Preparing to install the air conditioner. Read these instructions completely and carefully. Safety Instructions Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support Before You Begin NOTETOINSTALLER: Leave these instructions with the air conditioner after installation is completed. NOTETOCONSUMER: Keep this Owner’s Manual and Installation Instructions for future use. IMPORTANT NOTES: For personal safety, this air conditioner must be properly grounded. It is important to have the wall outlet and circuit checked by a qualified electrician if there is any doubt as to whether a proper ground exists. Follow National Electric Codes (NEC) and/or local codes and ordinances. Electrical Requirements Some models require 115/120-volt a.c., 60 Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker. The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet. CAUTION: Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. Do not change the plug on the power cord of this air conditioner. Aluminum house wiring may present special problems—consult a qualified electrician. Some models require 230/208-volt a.c., protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires. 9 Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions Installing a J-Model in an existing wall case. Read these instructions completely and carefully. IMPORTANT! GE strongly recommends the removal of the old wall case and the installation of a new GE Wall Case. If you decide to keep the existing wall case, you may need a kit to ensure proper performance. If you DONOT use a kit, you run the risk of poor performance or product failure. This is not covered under the terms of the GE warranty. J-Model Qualifying Questions J-model air conditioners may fit in existing wall cases. However, they often need a kit to properly adapt the case to the GE air conditioner. Answer these questions and see the chart below for the proper kit. C B A What brand air conditioner will you be replacing? What are the dimensions of the wall case currently in use? What is the model number of the chassis currently in use? What is the model...
Este manual também é adequado para os modelos :Aparelhos de ar condicionado - 10 DCA (481.9 kb)
Aparelhos de ar condicionado - 12 DCA (481.9 kb)