Specifications The refrigerating circuit is leak-proof. The machine is adaptive in followingsituation 1.Applicable ambient temperature range: Cooling Indoor Maximum:D.B/W.B 32oC/23oC 18oC/14oCMinimum:D.B/W.B Outdoor 43oC/26oC 18oC Maximum:D.B/W.B Maximum:D.B HeatingIndoor 27oC 15oC Maximum:D.B Maximum:D.B Outdoor 24oC/18oCMaximum:D.B/W.B Minimum:D.B/W.B -7oC/-8oC 2. If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. 3. If the fuse of indoor unit on PC board is broken,please change it with the type of T. 3.15A/ 250V. 4. The wiring method should be in line with the local wiring standard. 5. After installation, the power plug should be easily reached. 6. The waste battery should be disposed properly. 7. The appliance is not intended for use by young children or infirm persons without supervision. 8.Young children should be supervised to ensure that they do not play with the applience. 9.Please employ the proper power plug, which fit into the power supply cord. 10 .The power plug and connecting cable must have acquired the local attestation. 2 CautionsSafety Instruction CautionsSafety Instruction Please read the following Safety Instructions carefully prior to use. The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use. Installation WARNING Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. lnstallation in a inadequate place may cause accidents. Do not install in the following place. STRICT ENFORCEMENT Connect the earth cable. earthing Do not install in the place where there is any possibility of inflammable gas leakage around the unit. Do not get the unit exposed to vapor or oil steam. Check proper installation of the drainage securely PROHIBITION PROHIBITION CAUTION 3 Cautions WARNING Cautions WARNING When abnormality such as burnt-small found, immediately stop the operation button andcontact sales shop. OFF ENFORCEMENT STRICT Use an exclusive pcircuit breaker ower source with aConnect power supply cordto the outlet completely STRICT ENFORCEMENT Use the proper voltage STRICT ENFORCEMENT Do not use power supply cord extended or connected in halfway PROHIBITION Do not use power supply cordin a bundle. PROHIBITION Take care not to damagethe power supply cord. PROHIBITION Do not insert objects into the airinlet or outlet. PROHIBITION PROHIBITION Do not start or stop theoperation by disconnectingthe power supply cord and so on. Do not channel the air flow directlyat people, especially at infants orthe aged. PROHIBITION Do not try to repair or reconstructby yourself. Do not use for the purpose of storage offood, art work, precise equipment, breeding, or cultivation. Take fresh air occasionally especially when gas appliance is running at the same time. PROHIBITION STRICT ENFORCEMENT Do not operate the switch with wet hand. PROHIBITION PROHIBITION PROHIBITION PROHIBITION PROHIBITION Do not install the unit near a fireplaceor other heating apparatus. Check good condition of the installation stand Do not pour water onto the unitfor cleaning PROHIBITION Do not place animals or plants inthe direct path of the air flow Do not place any objects on orclimb on the unit. Do not place flower vase or watercontainers on the top of the unit. PROHIBITION CAUTION 4 Indoor unit Parts and Functions Indoor unit Parts and Functions Display board Inlet Anion generator (inside) Vertical flap (Use remote controller to adjust up and down air flow. Don't adjust it manually) Horizontal louver (adjust left and right air flow) Actual inlet grille may vary from the one shown in the manual according tothe product purchased Air filter Inlet grille (inside) Outdoor unit 1 2 OUTLET 3 4 CONNECTING PIPING AND ELECTRICAL WIRING INLET DRAIN HOSE 5 STERILIZE FRESH STERILIZE FRESH 28 33 1.CODEUsed to select CODE A or B with a press,A or B will be displayed on LCD. Please select A without special explanation. 2.RESET When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote controller normal. 3.LIGHT button Control the lightening and extinguishing of the indoor LCD display board. 4. TIMER buttonUsed to select TIMER ON, TIMER OFF, TIMER ON-OFF. 5. CLOCK button Used to set correct time. 6. SLEEP button Used to select sleep mode. 7. MODE button AUTO COOL DRY FAN 8. HOUR button Used to set clock and timer setting. Parts and Functions 18 2434 16 17 19 9. HEALTH button Used to set healthy operation. 10. ON/OFF button Used for unit start and stop. 11. TIMER ON display 12. FAN SPEED display LOW HIMED AUTO 13. LOCK display 14. SWING UP/DOWN display 15. SLEEP display 16. HEALTH display 17.FRESH AIR display 18. Operation mode display Operation mode AUTO COO...