Log:
Assessments - 2, GPA: 4.5 ( )

Instruções de Operação Kenmore, Modelo 580.75281

Fabricante : Kenmore
Arquivo Tamanho: 1.79 mb
Arquivo Nome : L0503367.pdf
Língua de Ensino: enes
Ir para baixar



Facilidade de uso


3 ELECTRICAL REQUIREMENTS .......4 INSTALLING THE POWER CORD....4 INSTALLATION ........................................5 Installation Requirements ......................... 5 installation ................................................ 6 How to Install ............................................ 6 Removal from Window ................................. 8 OPERATION .............................................9 How and Why ........................................... 9 Normal Sounds ........................................ 9 Capacity and Running Time ..................... 9 FULL ONE YEAR WARRANTY ON ROOM AIR CONDITIONER For one year from the date of purchase, when this air conditioner is operated and maintained for normal room cooling according to the instructions in this owner's manual, Sears will repair this air conditioner, free of charge, if defective in material or workmanship. FULL FIVE-YEAR WARRANTY ON SEALED REFRIGERATION SYSTEM For five years from the date of purchase, when this air conditioner is operated and maintained for normal room cooling according to the instructions in this owner's manual, Sears will repair the sealed refrigeration system (consisting of refrigerant, connecting tubing, and compressor), free of charge, if defective in material or workmanship. Features ................................................. 10 Using the Air Conditioner ....................... 10 Display ................................................... 11 Remote Control ...................................... 12 MAINTENANCE .....................................13 Air Filter Cleaning ................................... 13 Air Conditioner Cleaning ........................ 13 How to Remove the Front Gdlle .................. 13 How to Replace the Front Grille .................. 13 TROUBLESHOOTING .........................14 Before Calling for Service ...................... 14 ESPANOL ................................................15 MASTER PROTECTION AGREEMENTS ......................................31 SERVICE NUMBERS ............ Back Cover WARRANTY SERVICE IS AVAILABLE BY CONTACTING SEARS SERVICE AT 1-800-4-MY-HOME ®. Warranty coverage applies only to air conditioners used for non-commercial, private household purposes. This warranty applies only while this product is in use in the United States. This warranty gives you specific legal rights, and you may also have other right which vary from state to state. Sears, Roebuck and Co., D/817WA, Hoffman Estates, IL 60179 U.S.A. -2 IMPORTANT SAFETY INSTRUCTIONS The safety instructions below will tell you how to use your room air conditioner to avoid harm to yourself or damage to your ROOM AIR CONDITIONER. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Read product labels for flammability and other warnings. PREVENT ACCIDENTS To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow basic precautions, including the following: • Be sure the electrical service is adequate for the model you have chosen. • If the air conditioner is to be installed in a window, you will probably want to clean both sides of the glass first. If the window is a triple-track type with a screen panel included, you may want to remove the screen completely before installation. • Be sure the air conditioner has been securely and correctly installed according to the separate installation instructions provided with this manual. Save this manual and installation instructions for possible future use in removing or reinstalling this unit. • Use gloves when handling the air conditioner. Be careful to avoid cuts from sharp metal fins on front and rear coils. V.'_V_Vl-'1;t_ll_[qELECTRICAL INFORMATION The complete electrical rating of your new room air conditioner is stated on the serial plate. Refer to the rating when checking the electrical requirements. • Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards. • Your air conditioner must be plugged into in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle. • Do not run air conditioner with a protective covering. This could result in mechanical damage within the air conditioner. • Do not use an extension cord or an adapter plug. _ Avoid fire hazard or electric shock. Do not use an extension cord or an adapter plug. Do not remove any prong from the power cord. prong Ground 3-prong 3-prong I _ I grounding plug I _\_ I type wall _._ receptacle supplycord Reset_ ENERGY SAVING IDEAS • The capacity of the room air conditioner must fit the room size for efficient and satisfactory operation. • Install the room air cond...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias