Log:
Assessments - 3, GPA: 3.7 ( )

Instruções de Operação Kenmore, Modelo 580.71121

Fabricante : Kenmore
Arquivo Tamanho: 632.66 kb
Arquivo Nome : efb97b5d-5f09-4522-a6f7-de1a6dff22d3.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Plug in the air conditioner.(To prevent electrical hazards, do not use an extension cord or an adapter plug.) 2. Set the exhaust vent to the CLOSE position. 3. Set the TEMP Control to the coolest setting. 4. Set the MODE control at the highest COOL level. 5. Adjust the louver for comfortable air flow. 6. Once the room has cooled, adjust the TEMP and MODE control to the setting you t_nd most comfortable, NOTE : If the air conditioner is turned off, wait 3 minutes before restarting. This allows pressure inside the compressor to equalize. Failure to wait 3 minutes before restarting may cause inefficient operation. If you move the TEMP Control to a warmer, then immediately back to a cooler setting, the unit will shut off. Wait 3 minutes before restarting. -10 AIR CONDITIONER FEATURES The controls featured in this manual are representative of the many models available. Your model may look slightly different. OFF 3e4. °6 o7 MEO " HiGH LOW MED FAN OOL _ • 8 FAN o_ "COOL 2• ° LOW COOL TEMP MODE FIG. 25 TEMP The thermostat will automatically control the temperature of the room. Select a higher number for lower room temperature. The temperature is selected by turning the TEMP knob to the desired position. The 5 or 6 position is a normal setting for average conditions. MODE OFF : Turns the air conditioner off. MED FAN : Medium fan speed operation without cooling. LOW FAN : Low fan speed operation without cooling. HIGH COOL : Cooling with the high fan speed operation. MED COOL : Cooling with the medium fan speed operation. LOW COOL : Cooling with the low fan speed operation. HORIZONTAL AIR DIRECTION CONTROL The horizontal air direction is adjusted by moving the vertical louvers right and left with your fingertips. (FIG. 26) VENT CONTROL The Vent Control allows the air conditioner to either recirculate inside air (CLOSE) or exhaust air to the outside (OPEN). (FIG. 27) • The CLOSE position is used when maximum cooling is desired. It may also be used for air recirculation without cooling when the air conditioner is set in the FAN position. • The OPEN position removes stale air from the room and exhausts it to the outside, Fresh air is drawn into the room through normal air passages found in homes. • The OPEN or CLOSE position can be used with any fan selection. PULL OPEN I PUSH CLOSE FIG. 27 VERTICAL AIR DIRECTION CONTROL The vertical air direction is adjusted by moving the horizontal louvers up and down with your fingertips. (FIG. 28) FIG. 28 FIG. 26 -11 AIR FILTER CLEANING The Air Filter will become dirty as it removes dust from the inside air. It should be washed at least every 2 weeks. If the Air Filter remains full of dust, the air flow will decrease and the cooling capacity will be reduced, possibly damaging the unit. -Pull the inlet grille forward, grasping both tabs, and pull out the air filter• (FIG. 29) • Wash the Air Filter under the faucet with warm water• Be sure to shake off all the water before replacing the filter. (FIG. 30), FIG. 29 FIG, 30 AIR CONDITIONER CLEANING Clean the front grille and inlet grille by wiping with a cloth dampened Kna mild detergent solution. The cabinet may be washed with mild soap or detergent and lukewarm water, then polished with liquid appliance wax. To ensure continued peak efficiency, the condenser coils (weather side at unit) should be checked periodically and cleaned if they become clogged with soot or dirt from the atmosphere• Brush or vacuum exterior coils to remove debris from fins. HOW TO REMOVE THE FRONT GRILLE • Remove the TEMP knob and the MODE knob by pulling. • Open the inlet grille downward. • Remove the screw securing the Front Grille. • Push the grille up from the bottom and pull the top of the grille away from the case to lift the top tabs out of their slots. Inlet Grille I . _ Front Grige m FIG. 32 HOW TO REPLACE THE FRONT GRILLE Attach the front grille to the cabinet by inserting the tabs on the grille into the tabs on the front of the cabinet• Push the grille in until it snaps into place• FIG. 31 -12 BEFORE CALLING FOR SERVICE Check the following list to be sure a service call is really necessary. A quick reference to this manual may help you avoid an unneeded service call. THE AIR CONDITIONER WILL NOT OPERATE Check if... Then... Wall Pfu9disconnected. Push PfuQfirmly intowall outlet. House fuse blown or circuit breaker thpped. Replace fuse with lime delay type or reset circuit breaker. MODE selector is OFF position. Turn MODE selector to the desired COOL setting. Unit was turned off and then on ton quickly, Turn unit off and wait 3 minutes before restartin9. TEMP Control set warmer than room temperature. Turn TEMP Control clockwise to a cooler setting (higher number). AIR FROM UNIT DOES NOT FEEL COLD ENOUGH. Check if... Then... MODEselectorinLOWCOOLposition. TumselectortoHIGHCOOLposition TEMPControlset tonwarm(lowernumber). TumTEMPConli'olclockwiseto a co_ersettin9. Roomtemperaturebelow70°F(21°C). Conlin9 maynotoccuruntilroomtemperaturerisesabove70°F(21°C). ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias