3 Remove the hex nut. The blade is held on with a hex nut tightened on the motor arbor shaft. Based on either right to left or left to right saw operation, the hex nut will be either a left hand or right hand thread. A right to left saw operation means that the product is entering the saw from the right side. A right to left operating saw will use a left-handed threaded arbor. This is done to insure that the arbor nut will want to continually tighten during blade rotation. The motor has an arrow on the housing to indicate the arbor rotation. Remove the hex nut using the spanner wrench provided to hold the blade shaft. The saw blades will be removable at this time. 3-8 INSTALLATION CTS Saw UGE058/0803 4 Make sure all components are installed according to assembly drawings. Make sure that all bolts on the saw have been tightened. Check that saw is firmly locked into position with the anchoring screws. Check that all wiring conforms to electrical codes, and all wiring covers are in place. Plug in the air supply PREPARING FOR TESTING 1 2 3 4 5 6 Turn on the main disconnect. Plug in the main TESTING THE power cord and turn on the main disconnect. INSTALLATION Check that the E-Stop button is in the out, extended position. Press the vacuum start button. Check the rotation of the vacuum motor for correct phasing. (The phase in your plant may be different from the Conair factory.) Press the saw start button. Turn off the saw and vacuum. Check the saw blade rotation. The top of the saw blade should turn towards the front or operator side. If the top of the blade is spinning away from you or the operator side switch one of the 3-phase plug wires. Then recheck the blade rotation. Make a sample cut. Restart the vacuum and the saw motor and press the manual cut button. The saw should make one sample cut. If the saw is not working properly at any time, turn it off immediately and refer to the Troubleshooting section of this User Guide. If you do not encounter any problems, proceed to the Operation section. UGE058/0803 CTS Saw INSTALLATION 3-9 OPERATION . The Saw Control . . . . . . . . . . . . .4-2 . Machine Frame and Support System . . . . . . . . . . . . . . . . . . . .4-4 . Blade Height Adjustment . . . . . .4-4 . Upper Clamp Adjustment . . . . .4-5 . Power Supply . . . . . . . . . . . . . . .4-5 . Control Panels . . . . . . . . . . . . . .4-5 . Pneumatic Cylinder Operation . . . . . . . . . . . . . . . .4-6 . Electrical Operation . . . . . . . . . .4-7 . Machine Lubrication . . . . . . . . .4-8 . System Inspection . . . . . . . . . .4-8 . Blade Replacement . . . . . . . . . .4-9 . Chip Collection Shrouds and Blower Connection . . . .4-10 UGE058/0803 CTS Saw THE SAW IMPORTANT:Before applying power, ensure that the SAW BLADE UP and TABLE FORWARD valves are CONTROL closed (fully clockwise), and that the saw blade is not installed on the cut-off saw. Connect the electrical line cord to a source of power com 1 patible with the nameplate on the saw cut-off saw. Connect the air supply to the FRL (filter-regulator-lubricator) 2 on the saw. If the optional dust collector was purchased, install and con 3 nect the dust collector Turn the main disconnect switch to the ON position; the 4 POWER ON light will illuminate. 5 Press Start or (if equipped with Dust Collector) turn Dust Collector power “ON” first and then press saw motor “START” Check the motor rotation. If the motor rotation is incorrect: 6 Reverse the connections at the AC plug end. 7 Once the rotation is correct, disconnect the power, and install the blade on the cut-off saw. 8 Make sure that the FRL is set for 6--65 PSI NOTE:Setting the FRL to higher level will only release air from the system.The CTS is equipped with a relief valve that is preset for approximately 70 PSI.The CTS is equipped with a relief valve that is preset for approximately 70 PSI.The relief valve is in place to protect the air components from damage due to excessive air pressure. Press MANUAL CUT 9 Adjust the TABLE FORWARD speed control to match the 10 approximate line speed. Adjust the SAW BLADE UP speed control to the desired 11 blade travel speed. 12 Set the blade height limit by adjusting the collar on the lifting rod (located on the table surface) continued on the next page 4-2 OPERATION CTS Saw UGE058/0803 Adjust the TABLE RETURN speed control to the13 suitable travel return speed. THE CONTROL FEATURES CONTINUED NOTE:The TABLE RETURN pressure must be set high enough to return the table to the start position and trig ger the TABLE START micro-switch. 14 Adjust the clamp pressure regulator to grasp the profile firmly. NOTE:Both the clamp pads and pressure can be adjusted so that the profile is not crushed. UGE058/0803 CTS Saw OPERATION 4-3 MACHINE FRAME AND SUPPORT SYSTEM The machine frame is constructed of welded steel that has been primed and painted to resist corrosion and provide a maintenance free finish. The frame is supported by, four leveling screws, that both permanently fix the posit...

Este manual também é adequado para os modelos :
Jig Saw e - CTS 5 (605.77 kb)
Jig Saw e - CTS 9 (605.77 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias