Log:
Assessments - 3, GPA: 4.3 ( )

Instruções de Operação Fujitsu, Modelo MHV2100BH

Fabricante : Fujitsu
Arquivo Tamanho: 1.57 mb
Arquivo Nome :
Língua de Ensino: en
Fotos e especificações  Fujitsu  MHV2100BH
Ir para baixar



Facilidade de uso


• Error reporting conditions (1) This command is issued twice or more in an operation sequence. (ST = 51h, ER = 10h) (2) The READ NATIVE MAX ADDRESS EXT command (27h) is not issued immediately before this command (ST = 51h, ER = 04h) is issued. (3) This command is issued in CHS mode (ST = 51h, ER = 04h) (4) The SET MAX ADDRESS command has already been issued. (ST = 51h, ER = 04h) (5) A SATA communication error occurred (ST = 51h, ER = 14h). C141-E224 5-133 Interface At command issuance (Shadow Block Registers setting contents) CM 0 0 1 1 0 1 1 1 DH 1 L 1 x xx CH EXP CH CL EXP CL SN EXP SN SC EXP SET MAX LBA (47-40) SET MAX LBA (23-16) SET MAX LBA (39-32) SET MAX LBA (15-8) SET MAX LBA (31-24) SET MAX LBA (7-0) xx SC xx VV FR EXP FR xx xx At command completion (Shadow Block Registers contents to be read) ST Status information DH 1 L 1 x xx CH EXP CH CL EXP CL SN EXP SN SC EXP SC ER SET MAX LBA (47-40) SET MAX LBA (23-16) SET MAX LBA (39-32) SET MAX LBA (15-8) SET MAX LBA (31-24) SET MAX LBA (7-0) xx xx Error information 5-134 C141-E224 5.3 Host Commands (45) WRITE MULTIPLE EXT (X’39’) • Description This command is the extended command of the WRITE MULTIPLE command. The LBA specification is increased from 28 bits to 48 bits, and the maximum number of sectors that can be transferred by a single command is changed from 100h to 10000h. Other command controls are the same as those of the WRITE MULTIPLE command. • Error reporting conditions (1) The command was issued in CHS mode (ST = 51h, ER = 04h). The other error reporting conditions are the same as those of the WRITE MULTIPLE command. At command issuance (Shadow Block Registers setting contents) CM 0 0 1 1 1 0 0 1 DH 1 L 1 x xx CH EXP CH CL EXP CL SN EXP SN SC EXP SC FR EXP FR LBA (47-40) LBA (23-16) LBA (39-32) LBA (15-8) LBA (31-24) LBA (7-0) Sector count (15-8) Sector count (7-0) xx xx At command completion (Shadow Block Registers contents to be read) ST Status information DH 1 L 1 x xx CH EXP CH CL EXP CL SN EXP SN SC EXP SC ER LBA (47-40) LBA (23-16) LBA (39-32) LBA (15-8) LBA (31-24) LBA (7-0) xx xx Error information C141-E224 5-135 Interface (46) WRITE LOG EXT (X'3F') The WRITE LOG EXTEND command writes versatile log data. Versatile log data includes the Extended SMART Comprehensive Error log, the Extended SMART Self-test log, and the SMART Selective log; and each log can be partially written with this command. The effectiveness of the log types depends on customization. For the protocol concerning data transfers, see Section 5.4. The number of a log to be written is specified as the Log address. For log data consisting of multiple sectors, a sector offset can be specified as an instruction so that data transfer starts from the specified sector. The number of sectors to be transferred is specified as the Sector count. If this command is not supported, or if an invalid value is specified for the Log address, Sector count, or Sector offset, the Aborted Command error occurs. • Error reporting conditions (1) An error was detected during power-on processing (ST = 51h, ER = 04h). (2) An error was detected during wake-up processing (in cases where wake-up processing is required before execution of this command) (ST = 51h, ER = 04h). (3) A write fault was detected while the write cache was disabled (ST = 71h, ER = 10h). (4) While the write cache is enabled, if the status indicating a completed transfer (STS = 50h) is returned and a data write operation failed because a write fault was detected during the data write operation, Abort will be returned for all subsequent ATA commands (ST = 71h, ER = 04h). This state is cleared the next time that the device is turned on. (5) An invalid log sector address or invalid Sector count (number of sectors to be transferred) is specified (ST = 51h, ER = 04h). (6) The failure prediction capability is disabled (ST = 51h, ER = 04h). (7) A check sum error was detected in the data transferred (ST = 51h, ER = 04h). (8) A SATA communication error occurred (ST = 51h, ER = 0Ch). 5-136 C141-E224 5.3 Host Commands At command issuance (Shadow Block Registers setting contents) CM 0 0 1 1 1 1 1 1 DH x x x x xx CH EXP CH CL EXP CL SN EXP SN SC EXP SC FR EXP FR xx xx Sector offset (15-8) Sector offset (7-0) xx Log address Sector count (15-8) Sector count (7-0) xx xx At command completion (Shadow Block Registers contents to be read) ST Status information DH x x x x xx CH EXP CH CL EXP CL SN EXP SN SC EXP SC ER xx xx xx xx xx xx xx xx Error information C141-E224 5-137 Interface (47) READ VERIFY SECTOR (S) EXT (X’42’) • Description This command is the extended command of the READ VERIFY SECTOR (S) command. The LBA specification is increased from 28 bits to 48 bits, and the maximum number of sectors that can be transferred by a single command is changed from 100h to 10000h. Other command controls are the same as those of the READ VERIFY SECTOR (S) command. • Error reporting conditions (1) The command was issued in CHS mode (ST = 51h, ER = 04h). ...

Este manual também é adequado para os modelos :
Jig Saw e - MHV2040BH (1.57 mb)
Jig Saw e - MHV2060BH (1.57 mb)
Jig Saw e - MHV2080BH (1.57 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias