Instruções de Operação Toshiba, Modelo MMU-AP0181MH

Fabricante : Toshiba
Arquivo Tamanho: 3.52 mb
Arquivo Nome :
Língua de Ensino:
Fotos e especificações  Toshiba  MMU-AP0181MH
Ir para baixar



Facilidade de uso


38 6. APPLIED CONTROL 6-1. Setup of Selecting Function in Indoor Unit (Be sure to Execute Setup by a Wired Remote Controller) Execute the setup operation while the unit stops. 6 3 5 2 4 1 ON / OFF FAN TEMP. SWING/FIXTIME MODE VENT UNITSET CL FILTER RESET TEST TIMER SET 1 Push SET , CL , and TEST buttons simultaneously for 4 seconds or more. The firstly displayed unit No. indicates the header indoor unit address in the group control. In this time, the fan of the selected indoor unit is turned on. 2 Every pushing UNIT button, the indoor unit numbers in the group control are successively displayed. In this time, the fan of the selected indoor unit only is turned on. 3 Specify the item code (DN) using the setup temperature and buttons. 4 Select the setup data using the timer time and buttons. (When selecting the DN code to “33”, change the temperature indication of the unit from “°C” to “°F” on the remote controller.) 5 Push SET button. (OK if display goes on.) • To change the selected indoor unit, return to procedure 2. • To change the item to be set up, return to procedure 3. 6 Pushing TEST button returns the status to normal stop status. 39 Table: Function selecting item numbers (DN) (Items necessary to perform the applied control at the local site are described.) DN Item Description At shipment 01 Filter display delay timer 0000 : None 0001 : 150H 0002 : 2500H 0003 : 5000H 0004 : 10000H 0002 : 2500H 02 Dirty state of filter 0000 : Standard 0001 : High degree of dirt (Half of standard time) 0000 : Standard 03 Central control address 0001 : No.1 unit to 0064 : No.64 unit 0099 : Unfixed 0099 : Unfixed 04 Specific indoor unit priority 0000 : No priority 0001 : Priority 0000 : No priority 06 Heating temp shift 0000 : No shift 0001 : +1°C 0002 : +2°C to 0010 : +10°C (Up to +6 recommended) 0002 : +2°C (Floor type 0000: 0°C) 0d Existence of [AUTO] mode 0000 : Provided 0001 : Not provided (Automatic selection from connected outdoor unit) 0001 : Not provided 0E Follows operation mode of the header unit 0000 : Does not follow 0001 : Follows 0000 : Not provided 0F Cooling only 0000 : Heat pump 0001 : Cooling only (No display of [AUTO] [HEAT]) 0000 : Heat pump 10 Type 0014: Compact 4-way Air Discharge Cassette 0014: Compact 4-way A/D only 11 Indoor unit capacity 0000 : Unfixed 0001 to 0034 According to capacity type 12 Line address 0001 : No.1 unit to 0030 : No.30 unit 0099 : Unfixed 13 Indoor unit address 0001 : No.1 unit to 0064 : No.64 unit 0099 : Unfixed 14 Group address 0000 : Individual 0001 : Header unit of group 0002 : Follower unit of group 0099 : Unfixed 1E Temp difference of [AUTO] mode selection COOL > HEAT, HEAT > COOL 0000 : 0 deg to 0010 : 10 deg (For setup temperature, reversal of COOL/HEAT by ± (Data value)/2) 0003 : 3 deg (Ts±1.5) 28 Automatic restart of power failure 0000 : None 0001 : Restart 0000 : None 2A Selection of option/error input (CN70) 0000 : Filter input 0001 : Alarm input (Air washer, et...

Este manual também é adequado para os modelos :
Receptores - MMU-AP0091MH (3.52 mb)
Receptores - MMU-AP0151MH (3.52 mb)
Receptores - MMU-AP0121MH (3.52 mb)
Receptores - MMU-AP0091MH (3.52 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias