|
Facilidade de uso
5 INSTALLATIONINSTALLATION UNIVERSAL PAN SLIDES As an alternative to universal pan slides, the 1200-UP model can be ordered as a “side rack” model which is equipped with two (2) side racks and three (3) chrome plated wire shelves per compartment. Universal Pan Slides, chrome plate SR-24447 Side Rail 16046 SIDE RACKS AND SHELVES Model 1200-UP that has been converted with side racks to accommodate full and half size U.S. Hotel and European Gastronorm pans or sheet pans on the side racks. Shelf SH-23738, stainless steel or SH-2733, chrome plate Side Rack SR-25271 D A N G E R DISCONNECT UNIT FROM POWER SOURCE BEFORE CLEANING OR SERVICING. CAUTION TO PREVENT PERSONAL INJURY, USE CAUTION WHEN MOVING OR LEVELING THIS APPLIANCE. 1200-S, 1200-UP • INSTALLATION/OPERATION/SERVICE MANUAL -PG. 6 I N S T A L L A T I O N S I T E I N S TA L L A T I O N A number of adjustments are associated with initial installation and start-up. It is important that these adjustments be conducted by a qualified service technician. Installation and start-up adjustments are the responsibility of the dealer or user. These adjustments include but are not limited to thermostat calibration, door adjustment, leveling, electrical hook-up and installation of optional casters or legs. LEVELING Level the oven from side-to-side and front-to- back with the use of a spirit level. For ovens installed with casters, it is important that the installation surface be level due to the probability of frequent oven repositioning. We recommend checking the level of the oven periodically to make certain the floor has not shifted nor the oven moved. NOTE: Failure to properly level this oven can cause improper function and will result in the uneven baking with products consisting of semi-liquid batter. RESTRAINT REQUIREMENTS —MOBILE EQUIPMENT W A R N I N G RISK OF ELECTRIC SHOCK. Appliance must be secured to building structure. Any appliance that is not furnished with a power supply cord but that includes a set of casters must be installed with a tether. Adequate means must be provided to limit the movement of this appliance without depending on or transmitting stress to the electrical conduit. The following requirements apply: 1. Maximum height of casters is 6" (152mm). 2. Two of the casters must of be the locking type. 3. Such mobile appliances or appliances on mobile stands must be installed with the use of a flexible connector secured to the building structure. A mounting connector for a restraining device is located on the lower back flange of the appliance chassis or on an oven stand, approximately 18" (457mm) from the floor. A flexible connector is not supplied by nor is it available from the factory. 1200-S, 1200-UP • INSTALLATION/OPERATION/SERVICE MANUAL -PG. 7 INSTALLATIONINSTALLATION ELECTRICAL 1. An identification tag is permanently mounted on the cabinet. 2. Plug cabinet into a properly grounded receptacle ONLY, positioning the unit so the power supply cord is easily accessible in case of an emergency. Arcing will occur when connecting or disconnecting the unit unless all controls are in the “OFF” position. 3. If necessary, a proper receptacle or outlet configuration as required for this unit, must be installed by a licensed electrician in accordance with applicable, local electrical codes. For 230V: To prevent an electrical shock hazard between the appliance and other appliances or metal parts in close vicinity, an equalization-bonding stud is provided. An equalization bonding lead must be connected to this stud and the other appliances / metal parts to provide sufficient protection against potential difference. The terminal is marked with the following symbol. NOTE: The appliance must be connected to an electrical circuit that is protected by an external GFCI outlet. C A U T I O N THIS SECTION IS PROVIDED FOR THE ASSISTANCE OF QUALIFIED SERVICE TECHNICIANS ONLY AND IS NOT INTENDED FOR USE BY UNTRAINED OR UNAUTHORIZED SERVICE PERSONNEL. D A N G E R ENSURE POWER SOURCE MATCHES VOLTAGE STAMPED ON APPLIANCE NAMEPLATE. D A N G E R To avoid electrical shock, this appliance MUST be adequately grounded in accordance with local electrical codes or, in the absence of local codes, with the current edition of the National Electrical Code ANSI/NFPA No. 70. In Canada, all electrical connections are to be made in according with CSA C22.1, Canadian Electrical Code Part 1 or local codes. E L E CT R I C A L -1 2 0 0 -S E L E C T R I C A L -1 2 0 0 -U P VOLTAGE PHASE CYCLE/ HZ AMPS KW VOLTAGE PHASE CYCLE/ HZ AMPS KW CORD & PLUG 120 at 120 1 60 8.3 1.0 NEMA 5-15P, 15A-125V PLUG 120 at 120 1 60 16.0 1.92 NEMA 5-20P, 20A-125V PLUG 208-240 (AGENCY) 1 60 4.2 1.0 NEMA 6-15P, 208-240 (AGENCY) 1 60 9.6 2.0 NEMA 6-15P, 240 1000Wat 208 1 60 3.6 .75 15A-250V PLUG 240 2000Wat 208 1 60 7.2 1.5 15A-250V PLUG - at 240 1 60 4.2 1.0 (USA ONLY) - at 240 1 60 9.6 2.0 (USA ONLY) 08 208-240 (AGENCY) 1 60 8.4 2.0 NO CORD 08 208-240 (AGENCY) 1 60 19.3 4.0 NO CORD 22000Wat 208 1 60 7.2 1.5 NO...
Este manual também é adequado para os modelos :Móveis - Halo Heat 1200-S (6.51 mb)