Log:
Assessments - 3, GPA: 3.7 ( )

Instruções de Operação DeVillbiss Air Power Company, Modelo Excell A17913

Fabricante : DeVillbiss Air Power Company
Arquivo Tamanho: 1.31 mb
Arquivo Nome : 755dbd52-4e7b-4c07-8e19-aa6f7ee2e1fc.pdf
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


Grasp end of nozzle and turn until cleaning solution application unit is oriented correctly. 9 - ENG A17913 4. Remove the cleaning solution application tank from the application nozzle. a 5. Soap mixture pressure can be adjusted by adjusting the pipe located in the cleaning solution application nozzle (a). a. Pull pipe (b) from cleaning solution application nozzle. b b. Position the notch (c) on the pipe to the desired soap mixture 1-6, 1 being the highest and 6 being the lowest. c c. Press pipe into position. 6. Fill application tank with detergent. 7. Push cleaning solution application tank onto cleaning solution application nozzle. Turn to lock into place. 8. See Before Starting and Starting Your Pressure Washer paragraphs in this section to continue. A17913 10- ENG READ AND UNDERSTAND ALL WARNINGS BEFORE STARTING UNIT Risk of fluid injection and laceration. When using the high pressure setting, DO NOT allow the high pressure spray to come in contact with unprotected skin, eyes, or with any pets or animals. Serious injury can occur. Your washer operates at fluid pressures and velocities high enough to penetrate human and animal flesh, which could result in amputation or other serious injury. Leaks caused by loose fittings or worn or damaged hoses can result in injection injuries. DO NOT TREAT FLUID INJECTION AS A SIMPLE CUT! See a physician immediately! Never pull water supply hose to move pres sure washer. This could damage hose and/or pump inlet. DO NOT use hot water, use cold water only. Never turn water supply off while pressure washer motor is running or damage to pump will result. This unit is equipped with an automatic stop mode. When the trigger is released the motor is shut off automatically. When the trigger is pressed again the motor will automatically start. The time between release and engagement must not be less than 4-5 seconds. DO NOT leave the unit in automatic stop mode for more than 15 minutes. Stand on a stable surface and grip gun/wand firmly with both hands. Expect the gun to kick when triggered. This product is intended for intermittent use only. Operate pressure washer one hour or less in a 2 hour period. For outdoor use only. Store indoors. If you do not understand these precautions please call 1-866-422-4286 to speak to a service representative for further instructions. BEFORE STARTING 1. Move pressure washer to level ground. 2. Make sure the ON/OFF switch is in the OFF position To reduce the risk of electrocution, keep all connections dry and off the ground. Do not touch plug with wet hands. Do not use if cord is damaged. 3. Plug the unit into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. See the GROUNDING paragraph. 4. Press reset button and indicator light (a) will appear. You will have one of the following GFCI switches shown below. c b a a c b a c b 11 - ENG A17913 5. Test GFCI switch before each use, to test: a. Press test button (b), indicator light will disappear. c. Press reset button (c) to use unit. If indicator light does not reappear DO NOT use unit, see troubleshooting guide. 6. Con nect the high pressure hose (i) to the water outlet on the unit. The water outlet is marked OUT. 7. Assemble quick-connect adapter (k) to water inlet. i k 8. Connect the quick-connect (j) to the water supply hose. Risk of property damage. To reduce the possibility of contamination always protect against backflow when connected to a potable water system. 9. Connect quick-connect (j) to quick connect adapter (k) at the water inlet. j kj NOTE: The water supply must provide a minimum of 5 gallons per minute. 10. Make sure high pressure hose and water supply hose are securely connected. Risk of fluid injection and laceration. Always relieve sys tem pres sure before changing accessories. Place on/off switch in off position, turn off water sup ply, and pull gun trigger until water stops fl owing. 11. Connect the desired nozzle to spray wand. To connect rotary (a) and variable spray nozzle (b), turn clockwise until it snaps into place. To remove nozzle, turn nozzle counter clockwise to remove. To connect chemical application unit (c) see How To Use Cleaning Solution Application Unit in this section. 12. Turn water supply on. a b c A17913 12- ENG STARTING NOTE: Make sure water supply is turned on. 1. Disengage the safety catch as shown. Depress trigger to allow air to escape and to discharge residual pressure in the pipes. 2. With the trigger depressed, place the ON-OFF switch in the On position. When starting motor, always keep the trigger depressed. Risk of fluid injection and laceration. Always engage the trigger lock when gun is not in use. Failure to do so could cause accidental spraying. Risk of property damage. If after running unit for a few minutes it does not maintain steady water pressure, turn unit off to prevent damage to the unit and see the troubleshooting guide for instructions. RECOMMENDED CLEANING • On vertical ...

Este manual também é adequado para os modelos :
Equipamento de lavagem - Excell VR1600E (1.31 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias